Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Synchrotron Radiat ; 28(Pt 5): 1423-1436, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-34475290

ABSTRACT

Finite-element analysis is used to study the thermal deformation of a multilayer mirror due to the heat load from the undulator beam at a low-emittance synchrotron source, specifically the ESRF-EBS upgrade beamline EBSL-2. The energy bandwidth of the double-multilayer monochromator is larger than that of the relevant undulator harmonic, such that a considerable portion of the heat load is reflected. Consequently, the absorbed power is non-uniformly distributed on the surface. The geometry of the multilayer substrate is optimized to minimize thermally induced slope errors. We distinguish between thermal bending with constant curvature that leads to astigmatic focusing or defocusing and residual slope errors. For the EBSL-2 system with grazing angles θ between 0.2 and 0.4°, meridional and sagittal focal lengths down to 100 m and 2000 m, respectively, are found. Whereas the thermal bending can be tuned by varying the depth of the `smart cut', it is found that the geometry has little effect on the residual slope errors. In both planes they are 0.1-0.25 µrad. In the sagittal direction, however, the effect on the beam is drastically reduced by the `foregiveness factor', sin(θ). Optimization without considering the reflected heat load yields an incorrect depth of the `smart cut'. The resulting meridional curvature in turn leads to parasitic focal lengths of the order of 100 m.

2.
Langmuir ; 32(49): 12955-12965, 2016 12 13.
Article in English | MEDLINE | ID: mdl-27951689

ABSTRACT

The solid-liquid interface formed by single terminated muscovite mica in contact with two different ionic solutions is analyzed using surface X-ray diffraction. Specular and nonspecular crystal truncation rods of freshly cleaved mica immersed in CsCl or RbBr aqueous solution were measured. The half monolayer of the surface potassium ions present after the cleavage is completely replaced by the positive ions (Cs+ or Rb+) from the solution. These ions are located in the ditrigonal surface cavities with small outward relaxations with respect to the bulk potassium position. We find evidence for the presence of a partly ordered hydration shell around the surface Cs+ or Rb+ ions and partly ordered negative ions in the solution. The lateral liquid ordering induced by the crystalline surface vanishes at distances larger than 5 Å from the surface.

3.
Rev Sci Instrum ; 87(11): 113705, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910601

ABSTRACT

We have developed a new instrument combining a scanning probe microscope (SPM) and an X-ray scattering platform for ambient-pressure catalysis studies. The two instruments are integrated with a flow reactor and an ultra-high vacuum system that can be mounted easily on the diffractometer at a synchrotron end station. This makes it possible to perform SPM and X-ray scattering experiments in the same instrument under identical conditions that are relevant for catalysis.

SELECTION OF CITATIONS
SEARCH DETAIL
...