Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Expert Rev Hematol ; 8(5): 659-67, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26343891

ABSTRACT

Hodgkin lymphoma (HL) is highly curable lymphoma with combined multiagent chemotherapy with or without radiation. In spite of higher cure rates, approximately 20-30% cases will be either refractory or relapse after first line therapy. For relapse/refractory HL, salvage chemotherapy followed by autologous stem cell transplant remains the standard of care. Because of early and late toxicities of multiagent chemotherapy, there are ongoing efforts to find less toxic therapies to treat HL. Brentuximab vedotin is an antibody drug conjugate targeting CD30 with high response rates in HL. In the last decade, immune oncology has changed the treatment paradigm of cancers. Biologically, Reed-Sternberg cells evade immune system by exploiting checkpoint pathways. Inhibition of checkpoint pathway has shown promising activity in HL. Recently, phosphatidyl-inositide 3 kinase inhibitors and Janus kinase inhibitors have shown impressive responses in HL. In this article, we discuss novel agents in HL.


Subject(s)
Antineoplastic Agents/therapeutic use , Hodgkin Disease/drug therapy , Molecular Targeted Therapy , Antineoplastic Agents/pharmacology , Antineoplastic Combined Chemotherapy Protocols/adverse effects , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Clinical Trials as Topic , Combined Modality Therapy , Hematopoietic Stem Cell Transplantation , Hodgkin Disease/diagnosis , Hodgkin Disease/etiology , Humans , Salvage Therapy , Transplantation, Autologous , Treatment Outcome
2.
Echocardiography ; 30(8): 967-75, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23889489

ABSTRACT

In this retrospective study, we identified 7 cases where Lambl's excrescences were identified by two-dimensional transesophageal echocardiography (2DTEE) and also had live/real time three-dimensional transesophageal echocardiography (3DTEE) studies available for comparison. We subsequently assessed them for the presence of Lambl's excrescences (LE) and nodules of Arantius (NA) on the aortic valve. After their identification, we qualitatively and quantitatively organized our findings by number, cusp location, measurements, and orientation if applicable. A greater number of LE was found by 3DTEE than 2DTEE (19 vs. 11, respectively). In all 3DTEE studies, their cusp attachment site, their x-, y-, and z-axis measurements, and orientation were clearly visualized and described. Only 3DTEE studies provided confident visualization of the cusp attachment sites. Similarly, a greater number of NA was found by 3DTEE than 2DTEE (21 vs. 5, respectively). The triad of NA was visualized in all 3DTEE studies and each was described using its x-, y-, and z- axis measurements. Only three 2DTEE studies provided reliable identification of the NA. In conclusion, we present further evidence of the incremental value of 3DTEE over 2DTEE in the qualitative and quantitative assessment of cardiac structures including LE and NA on the aortic valve.


Subject(s)
Algorithms , Aortic Valve/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Echocardiography/methods , Heart Defects, Congenital/diagnostic imaging , Heart Valve Diseases/diagnostic imaging , Image Enhancement/methods , Aged , Bicuspid Aortic Valve Disease , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
4.
Echocardiography ; 29(6): 751­756, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22962695

ABSTRACT

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Subject(s)
Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/etiology , Heart Valves/diagnostic imaging , Computer Systems , Female , Humans , Middle Aged
5.
Echocardiography ; 29(9): 1128-31, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22931539

ABSTRACT

Percutaneous closure of secundum atrial defects has become an accepted treatment in part because it is minimally invasive and relatively low risk. Despite recent advances in implantation technique and device improvements, complications occur. Here, we report a case of device embolization during percutaneous repair of an atrial septal defect (ASD) with multiple fenestrations. We highlight the value of using live/real time three-dimensional transesophageal echocardiography to help plan the percutaneous procedure and detect complications.


Subject(s)
Echocardiography, Three-Dimensional/methods , Echocardiography, Transesophageal/methods , Embolization, Therapeutic/instrumentation , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/surgery , Iliac Artery/surgery , Surgery, Computer-Assisted/methods , Humans , Male , Septal Occluder Device , Treatment Outcome
6.
Echocardiography ; 29(7): 858-60, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22747462

ABSTRACT

Pericardial cysts are rare anomalies of the pericardium that are usually asymptomatic and followed by two-dimensional (2D) echocardiography. Here we report a large pericardial cyst that could not be measured accurately by 2D echocardiography but three-dimensional (3D) echocardiography enabled measurements of the cyst that correlated well with computed tomography measurements. In addition, 3D echocardiography demonstrated the mono-trabeculated nature of the cyst further suggesting the incremental value of 3D echocardiography in the evaluation of pericardial cysts. The cyst was subsequently resected surgically.


Subject(s)
Echocardiography, Three-Dimensional/methods , Mediastinal Cyst/ultrastructure , Computer Systems , Echocardiography , Female , Humans , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
7.
Echocardiography ; 29(8): 991-6, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22747757

ABSTRACT

Cholelithiasis is a very common disease in the United States. Most cases remain asymptomatic but a fraction of these patients can develop serious complications such as cholecystitis which may lead to gallbladder perforation and gallbladder cancer which is much less common. Here, we present three cases of cholelithiasis where transthoracic echocardiography was performed routinely. In each case, echocardiography detected cholelithiasis which prompted three-dimensional (3D) echocardiographic evaluation. Three-dimensional echocardiography allowed for more comprehensive examination of the gallbladder shape, size, and wall thickening and the measurement and composition of the stones in three dimensions, measurement of stone volumes, and minimized shadowing produced by stone calcifications. These cases suggest that routine echocardiography has value in detecting gallstones and that 3D echocardiography has incremental value over two-dimensional echocardiography due to pyramidal data sets which allow sequential slicing through the gallbladder and full gallbladder examination without a technologist who is trained in gallbladder imaging. These pyramidal data sets can be further viewed and cropped by a radiologist specialized in abdominal ultrasound.


Subject(s)
Cholelithiasis/diagnostic imaging , Diagnostic Tests, Routine/methods , Echocardiography/methods , Gallbladder/diagnostic imaging , Adult , Female , Humans , Middle Aged
8.
Echocardiography ; 29(5): 620-30, 2012 May.
Article in English | MEDLINE | ID: mdl-22537236

ABSTRACT

We compared findings from intraoperative live/real time three-dimensional transesophageal echocardiography (3DTEE) and two-dimensional transesophageal echocardiography (2DTEE) with surgery in 67 patients having aortic aneurysm and/or aortic dissection. Of these, 20 patients had aortic aneurysm without dissection, 21 aortic aneurysm and dissection, and 26 aortic dissection without aneurysm. 3DTEE diagnosed the type and location of aneurysm correctly in all patients unlike 2DTEE, which missed an aneurysm in one case. There were four cases of aortic aneurysm rupture. Three of them were diagnosed by 3DTEE but only one by 2DTEE, and one missed by both techniques. The mouth of saccular aneurysm, site of aortic aneurysm rupture, and communication sites between perfusing and nonperfusing lumens of aortic dissection could be viewed en face only with 3DTEE, enabling comprehensive measurements of their area and dimensions as well as increasing the confidence level of their diagnosis. In all patients with aortic dissection, 3DTEE enabled a more confident diagnosis of dissection because the dissection flap when viewed en face presented as a sheet of tissue rather than a linear echo seen on 2DTEE which can be confused with an artifact. 2DTEE missed dissection in one patient. In six cases the dissection flap involved the right coronary artery orifice by 3DTEE and surgery. These were missed by 2DTEE. Aortic regurgitation severity was more comprehensively assessed by 3DTEE than 2DTEE. Aneurysm size by 3DTEE correlated well with 2DTEE and surgery/computed tomography scan. In conclusion, 3DTEE provides incremental information over 2DTEE in patients with aortic aneurysm and dissection.


Subject(s)
Aortic Aneurysm/diagnostic imaging , Aortic Dissection/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Echocardiography/methods , Adult , Aged , Aged, 80 and over , Computer Systems , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Young Adult
9.
Echocardiography ; 29(3): E72-7, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22432650

ABSTRACT

We present an adult with metastatic carcinoid disease affecting the heart, in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) provided incremental value over two-dimensional transthoracic echocardiography (2DTTE). Initial 2DTTE was able to demonstrate severe pulmonic and tricuspid regurgitation, but was unable to visualize the posterior leaflet of the tricuspid valve or the right (right anterior) leaflet of the pulmonic valve. Further analysis with 3DTTE demonstrated thickening, restricted mobility, and noncoaptation of all three leaflets of both the tricuspid and the pulmonary valves. En face viewing of tricuspid and pulmonary regurgitation vena contractas permitted more reliable quantification of regurgitation severity. In addition, localized, linear, echogenic areas consistent with carcinoid deposits were noted along the inner walls of the right atrium, atrial septum, and inferior vena cava. To the best of our knowledge, endocardial carcinoid deposits have never been reported by 2D or 3D echocardiography. En face viewing of these deposits by 3DTTE enabled measurement of their dimensions and areas. Subcostal examination also identified large circumscribed hepatic lesions consistent with metastatic disease. Neither the carcinoid deposits nor the metastatic lesions were detected by 2DTTE. This case demonstrates the usefulness of 3DTTE as a supplement to 2DTTE in more comprehensively assessing carcinoid involvement of the heart.


Subject(s)
Carcinoid Heart Disease/complications , Carcinoid Heart Disease/diagnostic imaging , Echocardiography, Three-Dimensional/methods , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/etiology , Computer Systems , Female , Humans , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...