Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Cornea ; 40(10): 1316-1321, 2021 Oct 01.
Article in English | MEDLINE | ID: mdl-33758138

ABSTRACT

PURPOSE: To characterize vision-related quality of life after penetrating keratoplasty (PKP), deep anterior lamellar keratoplasty (DALK), Descemet stripping automated endothelial keratoplasty (DSAEK), and Descemet membrane endothelial keratoplasty (DMEK) using the National Eye Institute Visual Function Questionnaire (NEI-VFQ 9). METHODS: Using the Sight Outcomes Research Collaborative ophthalmology electronic health record repository, questionnaire responses were obtained from 103 PKP patients, 24 DALK patients, 42 DSAEK patients, and 50 DMEK patients undergoing postoperative examination. No exclusions were made based on preoperative diagnosis, age, complications, or comorbidities. Associations between clinical characteristics and vision-related quality of life were analyzed using nonparametric and linear regression methods. RESULTS: Patients were surveyed an average of 1.5 years postoperatively (range 24 d to 4.4 yrs). Participants who had undergone DALK, DMEK, DSAEK, and PKP had median composite VFQ scores of 77.8, 84.2, 76.1, and 70.6, respectively (P= 0.002). There were no significant differences in VFQ scores between patients treated with DMEK versus DSAEK (P = 0.440) or between patients treated with PKP versus DALK (P = 1.000). Higher postoperative acuities in the operative and fellow eyes were associated with higher VFQ scores (P < 0.001 and P < 0.001). When controlling for postoperative acuity by regression modeling, surgery type was not associated with patient-reported composite VFQ scores. CONCLUSIONS: In this study, patient-reported vision-related quality of life was similar among DMEK and DSAEK participants and also among DALK and PKP participants. When controlling for postoperative acuity, vision-related quality of life was similar among all study participants, irrespective of the keratoplasty technique.


Subject(s)
Corneal Diseases/surgery , Corneal Transplantation , Patient Reported Outcome Measures , Quality of Life/psychology , Refraction, Ocular/physiology , Visual Acuity/physiology , Adult , Aged , Aged, 80 and over , Corneal Diseases/physiopathology , Corneal Diseases/psychology , Cross-Sectional Studies , Descemet Stripping Endothelial Keratoplasty , Female , Follow-Up Studies , Graft Survival/physiology , Humans , Keratoplasty, Penetrating , Male , Middle Aged , Sickness Impact Profile , Surveys and Questionnaires
2.
Eye Contact Lens ; 47(5): 288-291, 2021 May 01.
Article in English | MEDLINE | ID: mdl-33181528

ABSTRACT

OBJECTIVES: To describe visual outcomes with various contact lens modalities in patients with a history of ocular trauma who underwent surgical open globe repair. METHODS: Records of all patients with a history of open globe injury and repair at a tertiary care hospital between January 1, 2010, and December 31, 2016, were reviewed. Demographics, type of injury, and visual acuity were assessed before and after contact lens evaluation. RESULTS: Of 214 patients who underwent open globe repair, 29 (13.6%) were evaluated with a contact lens. Visual acuity improved in 97% (28 of 29) of patients from 1.47±0.75 to 0.67±0.71 logarithm of the minimal angle of resolution (logMAR) with manifest refraction to 0.28±0.45 logMAR with contact lenses (n=29; P<0.0001). Corneal opacity was the most common clinical indication (20 of 29) for fitting followed by aphakia (13 of 29). A range of contact lens modalities, including corneal rigid gas-permeable (12 of 28), soft (9 of 28), hybrid (3 of 28), scleral gas-permeable (2 of 28), and piggyback (2 of 28) lenses were prescribed. CONCLUSION: In this study, patients with a history of trauma and open globe repair with good neurosensory visual potential had improvements in visual acuity with contact lens greater than manifest refraction. Soft and gas-permeable lenses were used to improve visual acuity in patients with a history of open globe repair and corneal scarring, aphakia, iris abnormalities, or other ocular sequelae. Although corneal rigid gas-permeable lenses were prescribed most often, additional consideration should be given to other contact lens modalities, including soft, piggyback, hybrid, and scleral gas-permeable lenses.


Subject(s)
Aphakia , Contact Lenses , Cornea , Humans , Prosthesis Fitting , Visual Acuity
3.
Am J Physiol Lung Cell Mol Physiol ; 318(5): L1074-L1083, 2020 05 01.
Article in English | MEDLINE | ID: mdl-32186399

ABSTRACT

Activation of the inflammasome-caspase-1 axis in lung endothelial cells is emerging as a novel arm of the innate immune response to pneumonia and sepsis caused by Pseudomonas aeruginosa. Increased levels of circulating autacoids are hallmarks of pneumonia and sepsis and induce physiological responses via cAMP signaling in targeted cells. However, it is unknown whether cAMP affects other functions, such as P. aeruginosa-induced caspase-1 activation. Herein, we describe the effects of cAMP signaling on caspase-1 activation using a single cell flow cytometry-based assay. P. aeruginosa infection of cultured lung endothelial cells caused caspase-1 activation in a distinct population of cells. Unexpectedly, pharmacological cAMP elevation increased the total number of lung endothelial cells with activated caspase-1. Interestingly, addition of cAMP agonists augmented P. aeruginosa infection of lung endothelial cells as a partial explanation underlying cAMP priming of caspase-1 activation. The cAMP effect(s) appeared to function as a priming signal because addition of cAMP agonists was required either before or early during the onset of infection. However, absolute cAMP levels measured by ELISA were not predictive of cAMP-priming effects. Importantly, inhibition of de novo cAMP synthesis decreased the number of lung endothelial cells with activated caspase-1 during infection. Collectively, our data suggest that lung endothelial cells rely on cAMP signaling to prime caspase-1 activation during P. aeruginosa infection.


Subject(s)
Caspase 1/genetics , Cyclic AMP/metabolism , Endothelial Cells/metabolism , Pseudomonas aeruginosa/metabolism , Signal Transduction , 1-Methyl-3-isobutylxanthine/pharmacology , 8-Bromo Cyclic Adenosine Monophosphate/pharmacology , Adenine/analogs & derivatives , Adenine/pharmacology , Alprostadil/analogs & derivatives , Alprostadil/pharmacology , Animals , Caspase 1/metabolism , Cell Proliferation/drug effects , Colforsin/pharmacology , Cyclic AMP/agonists , Cyclic AMP/antagonists & inhibitors , Cyclic GMP/analogs & derivatives , Cyclic GMP/pharmacology , Dinoprostone/pharmacology , Endothelial Cells/drug effects , Endothelial Cells/microbiology , Endothelial Cells/pathology , Gene Expression Regulation , Host-Pathogen Interactions/genetics , Inflammasomes/drug effects , Inflammasomes/genetics , Inflammasomes/metabolism , Interleukin-1beta/genetics , Interleukin-1beta/metabolism , Lung/metabolism , Lung/microbiology , Lung/pathology , Primary Cell Culture , Pseudomonas aeruginosa/drug effects , Pseudomonas aeruginosa/growth & development , Rats , Rolipram/pharmacology , Single-Cell Analysis
5.
Clin Ophthalmol ; 11: 875-882, 2017.
Article in English | MEDLINE | ID: mdl-28507427

ABSTRACT

Intraocular pressure, a major modifiable risk factor for glaucoma, has been shown to fluctuate throughout the day in patients with glaucoma. The detection and measurement of this fluctuation may help guide the clinical management of glaucomatous individuals. The Sensimed Triggerfish contact lens sensor (CLS), which has recently gained approval for marketing in the USA, is designed to detect intraocular pressure-related changes in an eye over a 24-hour period. This review will provide an overview of the Triggerfish CLS, as well as summarize current clinical data pertaining to the device. Overall, the current evidence suggests that the Triggerfish CLS is safe and well tolerated, and provides reproducible results. One challenge of using the Triggerfish CLS is that it may only provide data on relative changes in intraocular pressure rather than absolute intraocular pressure. In addition, its validity at estimating intraocular pressure compared to other methods is still controversial. Despite these limitations, recent studies suggest a myriad of potential indications for the Triggerfish CLS, including predicting glaucomatous progression and predicting efficacy of glaucoma treatment. With further research, the Triggerfish CLS may become a useful tool for eye care practitioners.

6.
Invest Ophthalmol Vis Sci ; 57(1): 208-17, 2016 Jan 01.
Article in English | MEDLINE | ID: mdl-26803796

ABSTRACT

PURPOSE: The pathophysiology of vision loss in persons with diabetic retinopathy (DR) is complex and incompletely defined. We hypothesized that retinal pigment epithelium (RPE) and rod and cone photoreceptor dysfunction, as measured by dark adaptometry, would increase with severity of DR, and that pan-retinal photocoagulation (PRP) would exacerbate this dysfunction. METHODS: Dark adaptation (DA) was measured in subjects with diabetes mellitus and healthy controls. Dark adaptation was measured at 5° superior to the fovea following a flash bleach, and the data were analyzed to yield cone and rod sensitivity curves. Retinal layer thicknesses were quantified using spectral-domain optical coherence tomography (OCT). RESULTS: The sample consisted of 23 controls and 73 diabetic subjects. Subjects with moderate nonproliferative diabetic retinopathy (NPDR) exhibited significant impairment of rod recovery rate compared with control subjects (P = 0.04). Cone sensitivity was impaired in subjects with proliferative diabetic retinopathy (PDR) (type 1 diabetes mellitus [T1DM]: P = 0.0047; type 2 diabetes mellitus [T2DM]: P < 0.001). Subjects with untreated PDR compared with subjects treated with PRP exhibited similar rod recovery rates and cone sensitivities. Thinner RPE as assessed by OCT was associated with slower rod recovery and lower cone sensitivity, and thinner photoreceptor inner segment/outer segment layer was associated with lower cone sensitivity. CONCLUSIONS: The results suggest that RPE and photoreceptor cell dysfunction, as assessed by cone sensitivity level and rod- and RPE-mediated dark adaptation, progresses with worsening DR, and rod recovery dysfunction occurs earlier than cone dysfunction. Function was preserved following PRP. The findings suggest multiple defects in retinoid function and provide potential points to improve visual function in persons with PDR.


Subject(s)
Dark Adaptation/physiology , Diabetic Retinopathy/physiopathology , Laser Coagulation/methods , Retina/physiopathology , Retinal Rod Photoreceptor Cells/physiology , Visual Acuity , Adolescent , Adult , Aged , Diabetic Retinopathy/pathology , Diabetic Retinopathy/surgery , Female , Humans , Male , Middle Aged , Retina/pathology , Retina/surgery , Tomography, Optical Coherence/methods , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...