Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Intervent Radiol ; 40(9): 1454-1460, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28451810

ABSTRACT

PURPOSE: The purpose of this investigation was to evaluate human Thiel-embalmed cadavers with the addition of extracorporeal driven ante-grade pulsatile flow in the aorta as a model for simulation training in interventional techniques and endovascular device testing. MATERIALS AND METHODS: Three human cadavers embalmed according to the method of Thiel were selected. Extracorporeal pulsatile ante-grade flow of 2.5 L per min was delivered directly into the aorta of the cadavers via a surgically placed connection. During perfusion, aortic pressure and temperature were recorded and optimized for physiologically similar parameters. Pre- and post-procedure CT imaging was conducted to plan and follow up thoracic and abdominal endovascular aortic repair as it would be in a clinical scenario. Thoracic endovascular aortic repair (TEVAR) and endovascular abdominal repair (EVAR) procedures were conducted in simulation of a clinical case, under fluoroscopic guidance with a multidisciplinary team present. RESULTS: The Thiel cadaveric aortic perfusion model provided pulsatile ante-grade flow, with pressure and temperature, sufficient to conduct a realistic simulation of TEVAR and EVAR procedures. Fluoroscopic imaging provided guidance during the intervention. Pre- and post-procedure CT imaging facilitated planning and follow-up evaluation of the procedure. CONCLUSION: The human Thiel-embalmed cadavers with the addition of extracorporeal flow within the aorta offer an anatomically appropriate, physiologically similar robust model to simulate aortic endovascular procedures, with potential applications in interventional radiology training and medical device testing as a pre-clinical model.


Subject(s)
Aorta, Abdominal/surgery , Aorta, Thoracic/surgery , Endovascular Procedures/education , Endovascular Procedures/instrumentation , Equipment Safety , Models, Cardiovascular , Simulation Training , Aorta, Abdominal/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Cadaver , Embalming/methods , Humans , Perfusion , Pulsatile Flow , Tomography, X-Ray Computed
2.
J Biomech ; 49(7): 1009-1015, 2016 05 03.
Article in English | MEDLINE | ID: mdl-26903410

ABSTRACT

Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design and performance of such instruments. Understanding the effects of storage and preservation conditions on the mechanical properties of soft tissue has both clinical and experimental significance. To this end, we aimed to study the effects of tissue preservation (by 10% formalin and Thiel fluids) on the elastic properties of five different kinds of fresh tissues from pig and chicken; specifically fat, liver, muscle, tendon and cartilage. The tissue elasticity was measured intensively and strictly within a controlled timeline of 6 months by quantitative optical coherence elastography (OCE) system. Our findings suggest that the elasticity change of tissues in the formalin solution has an ascending trend, but that of Thiel remains almost constant, providing a more real texture and properties.


Subject(s)
Elastic Tissue , Elasticity Imaging Techniques/methods , Tissue Preservation , Adipose Tissue/physiology , Animals , Cartilage/physiology , Chickens , Elastic Cartilage , Elasticity , Liver/physiology , Muscles/physiology , Swine , Tendons/physiology
3.
Article in English | MEDLINE | ID: mdl-26672034

ABSTRACT

Image-guided surgery is today considered to be of significant importance in neurosurgical applications. However, one of its major shortcomings is its reliance on preoperative image data, which does not account for brain deformations and displacements that occur during surgery. In this work, we propose to tackle this issue through the incorporation of an ultrasound device within the type of biopsy needles commonly used as an interventional tool to provide immediate feedback to neurosurgeons during surgical procedures. To identify the most appropriate path to access a targeted tissue site, single-element transducers that look either forward or sideways have been designed and fabricated. Micromolded 1-3 piezocomposites were adopted as the active materials for feasibility tests and epoxy lenses have been applied to focus the ultrasound beam. Electrical impedance analysis, pulse-echo testing, and wire phantom scanning have been carried out, demonstrating the functionality of the needle transducers at [Formula: see text]. The capabilities of these transducers for intraoperative image guidance were demonstrated by imaging within soft-embalmed cadaveric human brain and fresh porcine brain.


Subject(s)
Neurosurgical Procedures/instrumentation , Surgery, Computer-Assisted/instrumentation , Transducers , Ultrasonography, Interventional/instrumentation , Animals , Brain/surgery , Equipment Design , Humans , Needles , Phantoms, Imaging , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...