1.
Radiol Med ; 115(7): 1003-14, 2010 Oct.
Article in English, Italian | MEDLINE | ID: mdl-20221710

ABSTRACT

PURPOSE: This study evaluated the impact of tube current (mAs) in delayed-enhancement computed tomography (CT) imaging for assessing acute reperfused myocardial infarction in a porcine model. MATERIALS AND METHODS: In five domestic pigs (mean weight 24 kg), the circumflex coronary artery was balloon-occluded for 2 h and then reperfused. After 5 days, CT imaging was performed following administration of iodinated contrast material. A 64-slice CT system was used to perform first-pass coronary angiography with a tube current of 15 mAs/kg [Arterial Phase (ART)] followed by two delayed-enhancement (DE) scans 15 min after contrast material administration, with a tube current of 15 mAs/kg and 37.5 mAs/kg, respectively (DE(1) and DE(2)). The mean heart rate decreased to 51±9 beats/min after administration of zatebradine (10 mg/kg IV). The data set was reconstructed during the end-diastolic phase of the cardiac cycle. Areas with DE, no reflow and remote myocardium [remote left ventricular (LV)] were calculated. CT values expressed in Hounsfield units (HU) were measured using five regions of interest (ROI): DE, no reflow, remote LV, LV cavity (LV lumen) and in air, respectively. Differences, correlations, image quality [signal-to-noise ratio (SNR)] and contrast resolution [contrast-to-noise ratio (CNR)] were calculated. RESULTS: Significant differences were found between attenuation of areas of DE, no reflow and remote LV (p<0.001) within the different scans. There was a fair correlation between DE and no-reflow attenuation (r=0.6; p<0.001). In DE(1) vs. DE(2), areas of DE and no reflow were not significantly different (p>0.05). The SNR and CNR were not significantly different in DE(1) vs. DE(2) (p>0.05). CONCLUSIONS: Tube current does not significantly affect infarction area, image quality or contrast resolution of DE imaging with CT.


Subject(s)
Contrast Media , Heart/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Myocardial Reperfusion , Tomography, X-Ray Computed , Animals , Coronary Angiography , Coronary Circulation , Myocardial Infarction/physiopathology , Myocardial Infarction/therapy , Sus scrofa , Tomography, X-Ray Computed/methods
2.
Radiol Med ; 115(1): 22-35, 2010 Feb.
Article in English, Italian | MEDLINE | ID: mdl-20017004

ABSTRACT

PURPOSE: Our purpose in this study was to compare the impact of contrast material volume in delayed-enhancement computer tomography (CT) imaging for assessing acute reperfused myocardial infarction. MATERIALS AND METHODS: In five domestic pigs (20-30 kg), the circumflex coronary artery (CX) was balloon-occluded for 2 h followed by reperfusion. After 5 days, CT imaging was performed after intravenous administration of iodinated contrast material (Iomeprol 400 mgI/ml; Bracco, Italy). A 64-slice multidetector CT (MDCT) (Sensation 64, Siemens) scanner was used for imaging, with standard angiography characteristics. Three scans were performed: first, coronary angiography at first pass with 1.25 gI/kg of contrast material (ART); and remaining delayed-enhancement (DE(1)-DE(2)) 15 min after administration of 1.25 (DE(1)) and 15 min after additional administration of 2.50 gI/kg (=total 3.75 gI/kg - DE(2)). Mean heart rate decreased to 51+/-9 bpm after intravenous administration of Zatebradine (10 mg/kg). Data sets were reconstructed during the end-diastolic phase of the cardiac cycle. Areas of infarction-enhanced (DE), no-reflow (no-reflow) and remote myocardial [remote left ventricle (LV)] were manually contoured. CT attenuation values (Hounsfield units) were measured using five regions of interest: DE, no-reflow, remote LV, left ventricular cavity (lumen LV) and in air. Differences, correlations, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. RESULTS: We found significant differences between the attenuation of DE, no-reflow and remote LV (p<0.001). DE and no-reflow size were assessed accurately with DEMDCT. In particular, SNR and CNR showed higher values in DE(2) (approximately 6.0 and 3.5, respectively; r(2)=0.90) vs. DE(1) (approximately 4.0 and 2.2, respectively; r(2)=0.85). CONCLUSIONS: The increase of contrast material volume determines a significant improvement in myocardial infarction image quality with DE-MDCT.


Subject(s)
Contrast Media/administration & dosage , Iopamidol/analogs & derivatives , Myocardial Infarction/diagnostic imaging , Myocardial Reperfusion , Tomography, X-Ray Computed , Animals , Disease Models, Animal , Iopamidol/administration & dosage , Reproducibility of Results , Sensitivity and Specificity , Sus scrofa
4.
J Interv Cardiol ; 8(4): 355-8, 1995 Aug.
Article in English | MEDLINE | ID: mdl-10172446

ABSTRACT

While radiation therapy has been known to cause myocardial and pericardial damage, its role in accentuating coronary artery disease in the absence of traditional cardiovascular risk factors has been controversial. As younger patients with treatable cancers are being treated with mediastinal radiation, coronary artery disease as a cause for severe chest pain should be entertained as a possible diagnosis. We describe a 25-year-old male who presented with an inferior wall myocardial infarction 6 years after receiving mediastinal radiation and chemotherapy for Hodgkin's disease. He was subsequently treated by directional atherectomy to a 95% lesion in the right coronary artery. Histological examination of the atherectomy specimen revealed evidence of radiation-induced endothelial damage that had resulted in plaque formation and subsequent ischemia. Possible mechanisms for radiation-induced coronary artery disease and treatment options are discussed.


Subject(s)
Atherectomy, Coronary , Coronary Disease/diagnosis , Coronary Disease/therapy , Radiation Injuries/diagnosis , Radiation Injuries/therapy , Adult , Coronary Disease/etiology , Hodgkin Disease/radiotherapy , Humans , Male