Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 85(21): 10321-9, 2013 Nov 05.
Article in English | MEDLINE | ID: mdl-24044609

ABSTRACT

Analysis of volatile organic compounds (VOCs) in breath holds great promise for noninvasive diagnostic applications. However, concentrations of VOCs in breath may change quickly, and actual and previous uptakes of exogenous substances, especially in the clinical environment, represent crucial issues. We therefore adapted proton-transfer-reaction-time-of-flight-mass spectrometry for real time breath analysis in the clinical environment. For reasons of medical safety, a 6 m long heated silcosteel transfer line connected to a sterile mouth piece was used for breath sampling from spontaneously breathing volunteers and mechanically ventilated patients. A time resolution of 200 ms was applied. Breath from mechanically ventilated patients was analyzed immediately after cardiac surgery. Breath from 32 members of staff was analyzed in the post anesthetic care unit (PACU). In parallel, room air was measured continuously over 7 days. Detection limits for breath-resolved real time measurements were in the high pptV/low ppbV range. Assignment of signals to alveolar or inspiratory phases was done automatically by a matlab-based algorithm. Quickly and abruptly occurring changes of patients' clinical status could be monitored in terms of breath-to-breath variations of VOC (e.g. isoprene) concentrations. In the PACU, room air concentrations mirrored occupancy. Exhaled concentrations of sevoflurane strongly depended on background concentrations in all participants. In combination with an optimized inlet system, the high time and mass resolution of PTR-ToF-MS provides optimal conditions to trace quick changes of breath VOC profiles and to assess effects from the clinical environment.


Subject(s)
Breath Tests/methods , Mass Spectrometry/methods , Volatile Organic Compounds/analysis , Algorithms , Humans , Limit of Detection , Protons
2.
Biotechnol Bioeng ; 109(12): 3059-69, 2012 Dec.
Article in English | MEDLINE | ID: mdl-22711525

ABSTRACT

We report on the implementation of proton transfer reaction-mass spectrometry (PTR-MS) technology for on-line monitoring of volatile organic compounds (VOCs) in the off-gas of bioreactors. The main part of the work was focused on the development of an interface between the bioreactor and an analyzer suitable for continuous sampling of VOCs emanating from the bioprocess. The permanently heated sampling line with an inert surface avoids condensation and interaction of volatiles during transfer to the PTR-MS. The interface is equipped with a sterile sinter filter unit directly connected to the bioreactor headspace, a condensate trap, and a series of valves allowing for dilution of the headspace gas, in-process calibration, and multiport operation. To assess the aptitude of the entire system, a case study was conducted comprising three identical cultivations with a recombinant E. coli strain, and the volatiles produced in the course of the experiments were monitored with the PTR-MS. The high reproducibility of the measurements proved that the established sampling interface allows for reproducible transfer of volatiles from the headspace to the PTR-MS analyzer. The set of volatile compounds monitored comprises metabolites of different pathways with diverse functions in cell physiology but also volatiles from the process matrix. The trends of individual compounds showed diverse patterns. The recorded signal levels covered a dynamic range of more than five orders of magnitude. It was possible to assign specific volatile compounds to distinctive events in the bioprocess. The presented results clearly show that PTR-MS was successfully implemented as a powerful bioprocess-monitoring tool and that access to volatiles emitted by the cells opens promising perspectives in terms of advanced process control.


Subject(s)
Bioreactors , Biotechnology/instrumentation , Cell Culture Techniques/instrumentation , Mass Spectrometry/methods , Volatile Organic Compounds/analysis , Equipment Design , Escherichia coli/metabolism , Fermentation , Oxygen/metabolism , Reproducibility of Results , Signal Processing, Computer-Assisted , Volatile Organic Compounds/chemistry , Volatile Organic Compounds/metabolism
3.
Appl Environ Microbiol ; 74(7): 2179-86, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18245241

ABSTRACT

A method for analysis of volatile organic compounds (VOCs) from microbial cultures was established using proton transfer reaction-mass spectrometry (PTR-MS). A newly developed sampling system was coupled to a PTR-MS instrument to allow on-line monitoring of VOCs in the dynamic headspaces of microbial cultures. The novel PTR-MS method was evaluated for four reference organisms: Escherichia coli, Shigella flexneri, Salmonella enterica, and Candida tropicalis. Headspace VOCs in sampling bottles containing actively growing cultures and uninoculated culture medium controls were sequentially analyzed by PTR-MS. Characteristic marker ions were found for certain microbial cultures: C. tropicalis could be identified by several unique markers compared with the other three organisms, and E. coli and S. enterica were distinguishable from each other and from S. flexneri by specific marker ions, demonstrating the potential of this method to differentiate between even closely related microorganisms. Although the temporal profiles of some VOCs were similar to the growth dynamics of the microbial cultures, most VOCs showed a different temporal profile, characterized by constant or decreasing VOC levels or by single or multiple peaks over 24 h of incubation. These findings strongly indicate that the temporal evolution of VOC emissions during growth must be considered if characterization or differentiation based on microbial VOC emissions is attempted. Our study may help to establish the analysis of VOCs by on-line PTR-MS as a routine method in microbiology and as a tool for monitoring environmental and biotechnological processes.


Subject(s)
Bacteria/metabolism , Fungi/metabolism , Mass Spectrometry/methods , Organic Chemicals/analysis , Bacteria/growth & development , Bacteria/isolation & purification , Environmental Monitoring/methods , Fungi/growth & development , Fungi/isolation & purification , Protons , Volatilization
SELECTION OF CITATIONS
SEARCH DETAIL
...