Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 322: 124689, 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38996762

ABSTRACT

Creatinine is the end product of the catabolism of creatine and creatine phosphate. Creatine phosphate serves as a reservoir of high-energy phosphate, especially in skeletal and cardiac muscle. Besides typical known changes in serum and urinary creatinine concentrations, rare cases associated with changes in serum and urinary creatine levels have been described in the literature in humans. These cases are mostly linked to an excessive intake of creatine ethyl ester or creatine monohydrate, often resulting in increased urine creatinine concentrations. In addition, it is known that at such elevated creatinine concentrations, creatinine crystallisation may occur in the urine. Analysis of crystals and urinary concrements, often of heterogenous chemical composition, may provide diagnostic and therapeutic hints to the benefit of the patient. The aim of the present work was to analyze urine crystals of unclear composition with microscopic and spectroscopic techniques. On routine microscopic analysis of urine, a preliminary suspicion of uric acid or creatinine crystals was expressed. The crystals were of a cuboid shape and showed polarization effects in microscopy. The dried urine sample was whitish-orange in colour, odourless and dissolved well in water. Protein concentration in dry weight (DW) urine was about 0.3 mg/mg. The measured zinc content in the studied sample was approximately 660 µg/g DW sample and copper content was approximately 64 µg/g DW sample. A lead signal of around 10 µg/g DW sample was also observed. UV-Vis analysis showed a maximum creatine peak around 220 nm, compatible with the spectrum of creatinine with a maximum peak of 230 nm. Using HPLC technique, an extreme high ratio of creatine to creatinine of about 38 was measured, which led to the conclusion of the occurrence of rare creatine crystals in urine.

2.
J Chemother ; 36(1): 35-44, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37272077

ABSTRACT

This study aimed to explore pharmacokinetics of voriconazole and its covariates in lung transplant recipients using population approach in order to propose dosing individualization. Data from routine therapeutic drug monitoring in adult lung transplant recipients treated with oral voriconazole were analysed with a three-stage population pharmacokinetic model using nonlinear mixed-effects modelling. Monte Carlo simulations based on final voriconazole pharmacokinetic model were used to generate the theoretical distribution of pharmacokinetic profiles at various dosing regimens. A total of 78 voriconazole serum concentrations collected from 40 patients were included in pharmacokinetic analysis. The only significant covariate was age for voriconazole clearance. Population voriconazole apparent clearance started at 32.26 L/h and decreased by 0.021 L/h with each year of patient's age, while population apparent volume of distribution was 964.46 L. Based on this model, we have proposed an easy-to-use dosing regimen consisting of a loading dose of 400 mg every 12 h for the first 48 h of treatment followed by maintenance dose of 300 mg every 12 h in patients aged up to 59 years, or by maintenance dose of 200 mg every 12 h in patients aged above 59 years.


Subject(s)
Drug Monitoring , Transplant Recipients , Adult , Humans , Aged , Voriconazole/pharmacokinetics , Monte Carlo Method , Lung , Models, Biological
3.
Antibiotics (Basel) ; 12(9)2023 Sep 01.
Article in English | MEDLINE | ID: mdl-37760696

ABSTRACT

Although posaconazole tablets show relatively low variability in pharmacokinetics (PK), the proportion of patients achieving the PK/PD target at the approved uniform dose for both prophylaxis and therapy is not satisfactory. The aim of this study was to develop a posaconazole population PK model in lung-transplant recipients and to propose a covariate-based dosing optimization for both prophylaxis and therapy. In this prospective study, 80 posaconazole concentrations obtained from 32 lung-transplant patients during therapeutic drug monitoring were analyzed using nonlinear mixed-effects modelling, and a Monte Carlo simulation was used to describe the theoretical distribution of posaconazole PK profiles at various dosing regimens. A one-compartment model with both linear absorption and elimination best fit the concentration-time data. The population apparent volume of distribution was 386.4 L, while an apparent clearance of 8.8 L/h decreased by 0.009 L/h with each year of the patient's age. Based on the covariate model, a dosing regimen of 200 mg/day for prophylaxis in patients ˃60 years, 300 mg/day for prophylaxis in patients ˂60 years and for therapy in patients ˃60 years, and 400 mg/day for therapy in patients ˂60 years has been proposed. At this dosing regimen, the PK/PD target for prophylaxis and therapy is reached in 95% and 90% of population, respectively, representing significantly improved outcomes in comparison with the uniform dose.

4.
Pharmaceutics ; 14(5)2022 Apr 20.
Article in English | MEDLINE | ID: mdl-35631489

ABSTRACT

Transscleral diffusion delivery of chemotherapy is a promising way to reach the vitreal seeds of retinoblastoma, the most common intraocular malignancy in childhood. In this in vivo study, the delivery of topotecan via lens-shaped, bi-layered hydrogel implants was combined with transconjunctival cryotherapy to assess whether cryotherapy leads to higher concentrations of topotecan in the vitreous. The study included 18 New Zealand albino rabbits; nine rabbits received a topotecan-loaded implant episclerally and another nine rabbits received transconjunctival cryotherapy superotemporally 2 weeks before implant administration. Median vitreous total topotecan exposures (area under the curve, AUC) were 455 ng·h/mL for the cryotherapy group and 281 ng·h/mL for the non-cryotherapy group, and were significantly higher in the cryotherapy group, similar to maximum levels. Median plasma AUC were 50 ng·h/mL and 34 ng·h/mL for the cryotherapy and non-cryotherapy groups, respectively, with no statistically significant differences between them. In both groups, AUC values in the vitreous were significantly higher than in plasma, with plasma exposure at only approximately 11-12% of the level of vitreous exposure. The results confirmed the important role of the choroidal vessels in the pharmacokinetics of topotecan during transscleral administration and showed a positive effect of cryotherapy on intravitreal penetration, resulting in a significantly higher total exposure in the vitreous.

5.
Int J Pharm ; 606: 120832, 2021 Sep 05.
Article in English | MEDLINE | ID: mdl-34175379

ABSTRACT

Treatment of retinoblastoma (Rb) has greatly improved in recent years in terms of survival and eye salvage rates, using mainly intra-arterial or intravitreal chemotherapy. However, the treatment of vitreous tumor seeding still represents a challenge and it is of great interest to develop new strategies to deliver pharmacologically sufficient drug amounts to the vitreous humor. In the present work, we present a lens-shaped bi-layered hydrogel implant for delivery of topotecan (TPT) via transscleral diffusion. The implant consists of an inner TPT-loaded poly(2-hydroxyethyl methacrylate) (pHEMA) layer adjacent to the sclera and an outer covering poly(2-ethoxyethyl methacrylate) (pEOEMA) layer impermeable to TPT. TPT-loaded pHEMA samples exhibit long-lasting in vitro cytotoxicity against the Rb cell line Y79. In an in vivo experiment, pHEMA/pEOEMA implants are successfully surgically administered to the posterior segment of rabbit eyes. The determination of TPT pharmacokinetics demonstrates the attainment of promising levels of TPT (10 ng/ml) in vitreous humor 8 h after implant placement. The results from the pilot experiment constitute the proof of principle for the use of the proposed implants as a drug delivery system for the local treatment of intraocular diseases.


Subject(s)
Retinal Neoplasms , Retinoblastoma , Animals , Hydrogels , Rabbits , Topotecan , Vitreous Body
6.
Folia Microbiol (Praha) ; 65(3): 475-482, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31654320

ABSTRACT

Vancomycin is often used in orthopedic surgery as a local prophylaxis of bacterial infection. The aim of this work was to compare the release of vancomycin and its biologically inactive crystalline degradation products (CDP-1) during in vitro experiments from different types of local antibiotic delivery systems (bone grafts and bone cements). The concentrations of vancomycin and its crystalline degradation products were determined by high-performance liquid chromatography. Each experiment was performed in a phosphate buffer solution over 21 days. Morselized bone grafts, synthetic bone cements Palacos and Copal, and synthetic bone grafts were tested as local carriers of vancomycin. The highest concentration approximately 670 mg/L of vancomycin was released from synthetic bone grafts Actifuse. Even after 21 days, the concentration of vancomycin was still above the minimum inhibitory concentration (MIC). The maximum concentration of vancomycin released in two experiments with human bone grafts exceeded 600 mg/L during the first day and was still above MIC level 21 days later when the experiment was concluded. By comparing the synthetic bone cements Palacos and Copal, Copal had the average maximum concentration of only 32.4 mg/L and Palacos 35.7 mg/L. The concentration of vancomycin fell below the MIC for vancomycin-resistant Staphylococcus aureus (VRSA) on the seventh day with Palacos and the ninth day with Copal. This study showed the insufficient concentration of released vancomycin from synthetic bone cements at the end of the experiment. For improvement of local prophylaxis, it would be beneficial to increase the amount of vancomycin in bone cements.


Subject(s)
Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/metabolism , Bone Cements/analysis , Vancomycin/analysis , Vancomycin/metabolism , Bone Transplantation , Chromatography, High Pressure Liquid , Humans , Methicillin-Resistant Staphylococcus aureus/drug effects , Microbial Sensitivity Tests
7.
PeerJ ; 7: e7695, 2019.
Article in English | MEDLINE | ID: mdl-31579595

ABSTRACT

A novel application of the liquid chromatography method combined with the triple quadrupole tandem mass spectrometry method was developed for the quantification of vitamin K1 and two forms of vitamin K2 (menaquinone-4, menaquinone-7) in human serum. Total chromatography time for each run was 9 min. Time required for the sample pretreatment procedures was approximately 4 h. The coefficients of variation (CVs) of intra-assay were 10.4%, 3.2 % and 2.3% for vitamin K1 in three levels of quality control samples; were 14.3%, 3.2% and 6.7% for menaquinone-4; and were 11.1%, 6.0% and 7.0% for menaquinone-7. The inter-assay CVs were 12.8%, 11.3% and 7.4% for vitamin K1; were 15.2%, 9.2% and 8.7% for menaquinone-4; and were 13.2%,11.1% and 7.2% for menaquinone-7. No interference was found between K1, menaquinone-4 and menaquinone-7, nor any deuterated internal standards. This method was then used to determine reference values for Caucasian populations of central European origin. Samples were measured from 191 healthy volunteers (51.2 ± 16.2 years (mean ± SD)) and the values concerning K1 were 0.044-1.357 ng/mL for women and 0.030-1.214 ng/mL for men. The values for menaquinone-4 and menaquinone-7 did not exhibit any differences between women and men, and were 0.050-1.598 and 0.074-0.759 ng/mL, respectively.

8.
J Clin Lab Anal ; 32(5): e22381, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29333616

ABSTRACT

BACKGROUND: New high-performance liquid chromatography (HPLC) method was developed for the determination of vitamin K1 and two forms of vitamin K2 (MK-4 and MK-7) in human serum, and the levels of vitamin K were determined in 350 samples of postmenopausal women. METHODS: Vitamin K was determined by HPLC with fluorescence detection after postcolumn zinc reduction. The detection was performed at 246 nm (excitation) and 430 nm (emission). The internal standard and 2 mL of ethanol were added to 500 µL of serum. The mixture was extracted with 4 mL of hexane, and solid phase extraction was then used. RESULTS: The HLPC method was fully validated. The intra- and interday accuracy and precision were evaluated on two QC samples by multiple analysis, and CV were less than 10%. The limit of quantification for MK-4 was found at 0.04 ng/mL, for K1 0.03 ng/mL, and for MK-7 0.03 ng/mL. The mean recoveries of the corresponding compounds were 98%-110%. Serum levels of MK-4, K1 , and MK-7 in postmenopausal women with osteoporosis were 0.890 ± 0.291 ng/mL, 0.433 ± 0.394 ng/mL, and 1.002 ± 1.020 ng/mL, respectively (mean ± SD). Serum levels of MK-4, K1 , and MK-7 in postmenopausal women without osteoporosis were 0.825 ± 0.266 ng/mL, 0.493 ± 0.399 ng/mL, and 1.186 ± 1.076 ng/mL, respectively (mean ± SD). CONCLUSION: New HPLC method for the determination of vitamins K1 , MK-4, and MK-7 in serum was evaluated and validated. This method is highly specific and sensitive with the low limit of quantification.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fluorescence , Postmenopause/blood , Vitamin K 1/blood , Vitamin K 2/blood , Female , Humans , Time Factors , Vitamin K 2/classification
9.
Clin Lab ; 63(2): 385-388, 2017 Feb 01.
Article in English | MEDLINE | ID: mdl-28182348

ABSTRACT

BACKGROUND: Three immunochemical methods for the determination of 25-(OH)-vitamin D and validated HPLC method for the determination of 25-(OH)-vitamin D3 and 25-(OH)-vitamin D2 were compared. 62 patient samples from postmenopausal women were measured and the results obtained by all these methods were compared. METHODS: We used three chemiluminescent assays for determination of 25-(OH)-vitamin D. 25-(OH)-vitamin D3 and 25-(OH)-vitamin D2 were determined by HPLC with UV detection (Agilent 1200). The chemiluminescent assays were performed using the Abbott Architect i4000SR analyzer (Abbott Laboratories, Germany), the ADVIA Centaur (Siemens, USA), and the Liaison XL (DiaSorin Inc, USA). The statistical evaluation was done using GraphPad Prism 6.0. RESULTS: The data were tested by Tukey's multiple comparison test. All methods showed significant differences in comparison with the immunochemical method from DiaSorin (p < 0.001 for Abbott, p < 0.05 for Siemens, and p < 0.0001 for HPLC). The comparison of the immunochemical method from Siemens with HPLC was also significant, p < 0.05. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. The non-significant difference was shown by the comparison of Abbott with HPLC and also Abbott with Siemens. Means for the 25-(OH)-vitamin D methods used were: Abbott 70.2 ± 24.2 nmol/L, Siemens 67.6 ± 27.9 nmol/L, DiaSorin 53.5 ± 17.1, and HPLC 82.4 ± 40.0 nmol/L. CONCLUSIONS: The comparison of the DiaSorin immunochemical assay with other tested methods showed the greatest deviation. The mean of DiaSorin measurements was 38% lower than the mean of HPLC measurements. According to the results of the DiaSorin method, most patients treated with vitamin D would not achieve the optimal level of 25-(OH)-vitamin D and this could negatively affect the clinical decision.


Subject(s)
25-Hydroxyvitamin D 2/blood , Calcifediol/blood , Chromatography, High Pressure Liquid , Fluorescent Antibody Technique, Direct , Fluorescent Antibody Technique, Indirect , Postmenopause/blood , Vitamin D/analogs & derivatives , Biomarkers/blood , Female , Humans , Luminescent Measurements , Predictive Value of Tests , Reproducibility of Results , Spectrophotometry, Ultraviolet , Vitamin D/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...