Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Respir Res ; 22(1): 289, 2021 Nov 10.
Article in English | MEDLINE | ID: mdl-34758818

ABSTRACT

BACKGROUND: For children and adults, the standard treatment for obstructive sleep apnea is the delivery of continuous positive airway pressure (CPAP). Though effective, CPAP masks can be uncomfortable to patients, contributing to adherence concerns. Recently, nasal high flow (NHF) therapy has been investigated as an alternative, especially in CPAP-intolerant children. The present study aimed to compare and contrast the positive airway pressures and expired gas washout generated by NHF versus CPAP in child nasal airway replicas. METHODS: NHF therapy was investigated at a flow rate of 20 L/min and compared to CPAP at 5 cmH2O and 10 cmH2O for 10 nasal airway replicas, built from computed tomography scans of children aged 4-8 years. NHF was delivered with three different high flow nasal cannula models provided by the same manufacturer, and CPAP was delivered with a sealed nasal mask. Tidal breathing through each replica was imposed using a lung simulator, and airway pressure at the trachea was recorded over time. For expired gas washout measurements, carbon dioxide was injected at the lung simulator, and end-tidal carbon dioxide (EtCO2) was measured at the trachea. Changes in EtCO2 compared to baseline values (no intervention) were assessed. RESULTS: NHF therapy generated an average positive end-expiratory pressure (PEEP) of 5.17 ± 2.09 cmH2O (mean ± SD, n = 10), similar to PEEP of 4.95 ± 0.03 cmH2O generated by nominally 5 cmH2O CPAP. Variation in tracheal pressure was higher between airway replicas for NHF compared to CPAP. EtCO2 decreased from baseline during administration of NHF, whereas it increased during CPAP. No statistical difference in tracheal pressure nor EtCO2 was found between the three high flow nasal cannulas. CONCLUSION: In child airway replicas, NHF at 20 L/min generated average PEEP similar to CPAP at 5 cm H2O. Variation in tracheal pressure was higher between airway replicas for NHF than for CPAP. The delivery of NHF yielded expired gas washout, whereas CPAP impeded expired gas washout due to the increased dead space of the sealed mask.


Subject(s)
Cannula , Carbon Dioxide/analysis , Continuous Positive Airway Pressure/methods , Respiration , Sleep Apnea, Obstructive/therapy , Child , Child, Preschool , Female , Humans , Male , Sleep Apnea, Obstructive/metabolism , Sleep Apnea, Obstructive/physiopathology , Trachea
2.
ERJ Open Res ; 7(1)2021 Jan.
Article in English | MEDLINE | ID: mdl-33569497

ABSTRACT

RATIONALE: Delivery of continuous positive airway pressure (CPAP) is the standard treatment for obstructive sleep apnoea in children and adults. Treatment adherence is a major challenge, as many patients find the CPAP mask uncomfortable. The study aim was to demonstrate the feasibility of delivered CPAP through customised nasal masks by assessing mask leak and comfort of customised masks compared to commercially available CPAP masks. METHODS: Six healthy adult volunteers participated in a crossover study including commercial masks in three different sizes (petite, small/medium and large) from the same supplier and a customised mask fabricated for each subject using three-dimensional facial scanning and modern additive manufacturing processes. Mask leak and comfort were assessed with varying CPAP levels and mask tightness. Leak was measured in real time using an inline low-resistance Pitot tube flow sensor, and each mask was ranked for comfort by the subjects. RESULTS: Mask leak rates varied directly with CPAP level and inversely with mask tightness. When ranked for comfort, three subjects favoured the customised mask, while three favoured a commercial mask. The petite mask yielded the highest mask leaks and was ranked least comfortable by all subjects. Relative mask leaks and comfort rankings for the other commercial and customised masks varied between individuals. Mask leak was comparable when comparing the customised masks with the highest ranked commercial masks. CONCLUSION: Customised masks successfully delivered target CPAP settings in all six subjects, demonstrating the feasibility of this approach.

3.
Respir Res ; 20(1): 149, 2019 Jul 12.
Article in English | MEDLINE | ID: mdl-31299963

ABSTRACT

BACKGROUND: Supplemental oxygen therapy is widely used in hospitals and in the home for chronic care. However, there are several fundamental problems with the application of this therapy such that patients are often exposed to arterial oxygen concentrations outside of the intended target range. This paper reports volume-averaged tracheal oxygen concentration measurements (FtO2) from in vitro experiments conducted using a physiologically realistic upper airway model. The goal is to provide data to inform a detailed discussion of the delivered oxygen dose. METHODS: A baseline FtO2 dataset using a standard, straight adult nasal cannula was established by varying tidal volume (Vt), breathing frequency (f), and continuous oxygen flow rate (QO2) between the following levels to create a factorial design: Vt = 500, 640, or 800 ml; f = 12, 17, or 22 min- 1; QO2 = 2, 4, or 6 l/min. Further experiments were performed to investigate the influence on FtO2 of variation in inspiratory/expiratory ratio, inclusion of an inspiratory or expiratory pause, patient interface selection (e.g. nasal cannula versus a facemask), and rapid breathing patterns in comparison with the baseline measurements. RESULTS: Oxygen concentration measured at the trachea varied by as much as 60% (i.e. from 30.2 to 48.0% of absolute oxygen concentration) for the same oxygen supply flow rate due to variation in simulated breathing pattern. Among the baseline cases, the chief reasons for variation were 1) the influence of variation in tidal volume leading to variable FiO2 and 2) variation in breathing frequency affecting volume of supplemental oxygen delivered through the breath. CONCLUSION: For oxygen administration using open patient interfaces there was variability in the concentration and quantity of oxygen delivered to the trachea over the large range of scenarios studied. Of primary importance in evaluating the oxygen dose is knowledge of the breathing parameters that determine the average inhalation flow rate relative to the oxygen flow rate. Otherwise, the oxygen dose cannot be determined.


Subject(s)
Lung/physiology , Models, Biological , Oxygen Inhalation Therapy/instrumentation , Oxygen Inhalation Therapy/methods , Respiratory Mechanics/physiology , Humans , Tidal Volume/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...