Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurosci Methods ; 336: 108625, 2020 04 15.
Article in English | MEDLINE | ID: mdl-32061690

ABSTRACT

BACKGROUND: Functional magnetic resonance imaging (fMRI) enables non-invasive examination of both the structure and the function of the human brain. The prevalence of high spatial-resolution (sub-millimeter) fMRI has triggered new research on the intra-cortex, such as cortical columns and cortical layers. At present, echo-planar imaging (EPI) is used exclusively to acquire fMRI data; however, susceptibility artifacts are unavoidable. These distortions are especially severe in high spatial-resolution images and can lead to misrepresentation of brain function in fMRI experiments. NEW METHOD: This paper presents a new method for correcting susceptibility artifacts by combining a T1-weighted (T1w) image and inverse phase-encoding (PE) based registration. The latter uses two EPI images acquired using identical sequences but with inverse-PE directions. In the proposed method, the T1w image is used to regularize the registration, and to select the regularization parameters automatically. The motivation is that the T1w image is considered to reflect the anatomical structure of the brain. RESULTS: Our proposed method is evaluated on two sub-millimeter EPI-fMRI datasets, acquired using 3T and 7T scanners. Experiments show that the proposed method provides improved corrections that are well-aligned to the T1w image. COMPARISON WITH EXISTING METHODS: The proposed method provides more robust and sharper corrections and runs faster compared with two other state-of-the-art inverse-PE based correction methods, i.e. HySCO and TOPUP. CONCLUSIONS: The proposed correction method used the T1w image as a reference in the inverse-PE registration. Results show its promising performance. Our proposed method is timely, as sub-millimeter fMRI has become increasingly popular.


Subject(s)
Artifacts , Magnetic Resonance Imaging , Brain/diagnostic imaging , Echo-Planar Imaging , Humans , Image Processing, Computer-Assisted
2.
J Pharm Sci ; 84(4): 502-7, 1995 Apr.
Article in English | MEDLINE | ID: mdl-7629745

ABSTRACT

HPLC analysis of an anti-infective ophthalmic solution (Albalon-A), containing the active drugs naphazoline and antazoline, revealed a degradation peak of unknown identity. To elucidate the identity of the degradant, the active drugs were each hydrolyzed by refluxing at high pH, and their respective hydrolysis products were isolated and spectrally characterized by NMR, FT-IR, and MS for conclusive structure elucidation. The degradant's identity was confirmed by HPLC-MS analysis of Albalon-A ophthalmic solution to be the antazoline hydrolysis product N-[(N-benzylanilino)acetyl]ethylenediamine (IV). A stability-indicating HPLC method was then developed which was able to resolve IV from the active drugs. This HPLC method was then validated for quantitating the active drugs and IV. Validation studies demonstrated linear UV response at 280 nm, recovery > 98%, good reproducibility, and a detection limit of 2 micrograms/mL IV. Overall, the data demonstrated that the HPLC method was quantitative and specific for antazoline, naphazoline, and IV. Analysis of an expired stabilitry lot of the ophthalmic solution indicated the concentration of IV was 0.002% (w/v).


Subject(s)
Antazoline/analysis , Naphazoline/analysis , Chromatography, High Pressure Liquid , Drug Stability , Hydrolysis , Magnetic Resonance Spectroscopy , Mass Spectrometry , Ophthalmic Solutions , Spectroscopy, Fourier Transform Infrared
SELECTION OF CITATIONS
SEARCH DETAIL
...