Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Nephrol ; 36(9): 2457-2465, 2023 12.
Article in English | MEDLINE | ID: mdl-37093492

ABSTRACT

BACKGROUND: In late 2018, the production of 51Chromium-labelled ethylenediamine tetra-acetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for measuring glomerular filtration rate, was halted. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) has been validated for GFR measurement with a single bolus injection, a procedure not suitable in patients with extracellular compartment hyperhydration. In such cases, a bolus followed by continuous infusion of the tracer is required. The aim of this study was to evaluate whether 99mTc-DTPA with the infusion protocol can replace 51Cr-EDTA for GFR measurement. METHODS: We conducted a prospective single centre study during February and March 2019. All patients referred for GFR measurement received both radiotracers simultaneously: 51Cr-EDTA and 99mTc-DTPA bolus and continuous infusion were administered concomitantly through the same intravenous route. Over four and a half hours, plasma and urine samples were collected to calculate urinary and plasma clearance. RESULTS: Twenty-two patients were included (mean age 63.4 ± 17.5 years; 68% men). Mean urinary clearance of 51Cr-EDTA and 99mTc-DTPA was 52.4 ± 22.5 mL/min and 52.8 ± 22.6 mL/min, respectively (p = 0.47), with a mean bias of 0.39 ± 2.50 mL/min, an accuracy within 10% of 100% (95% CI 100; 100) and a Pearson correlation coefficient of 0.994. Mean plasma clearance of 51Cr-EDTA and 99mTc-DTPA was 54.8 ± 20.9 mL/min and 54.4 ± 20.9 mL/min, respectively (p = 0.61), with a mean bias of - 0.43 ± 3.89 mL/min, an accuracy within 10% of 77% (95% CI 59; 91) and a Pearson correlation coefficient of 0.983. CONCLUSIONS: Urinary and plasma clearance of 99mTc-DTPA can be used with the infusion protocol to measure GFR.


Subject(s)
Kidney Diseases , Technetium Tc 99m Pentetate , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Chromium Radioisotopes , Edetic Acid , Glomerular Filtration Rate , Pentetic Acid , Prospective Studies , Technetium
2.
J Nephrol ; 34(3): 729-737, 2021 06.
Article in English | MEDLINE | ID: mdl-33661505

ABSTRACT

PURPOSE: The production of 51Cr-labelled ethylenediaminetetraacetic acid (51Cr-EDTA), a validated and widely used radio-isotopic tracer for glomerular filtration rate (GFR) measurement in Europe, was recently halted by the manufacturer. Technetium-99m-diethylenetriaminepentaacetic acid (99mTc-DTPA) clearance has so far mostly been restricted to assessment of separate renal function by scintigraphy, but scarcely used and validated for GFR measurement. We compared the performances of 51Cr-EDTA and 99mTc-DTPA for GFR and extracellular fluid measurement. METHODS: In a multi-centre prospective study, 51Cr-EDTA and 99mTc-DTPA were simultaneously injected into 88 patients, and their urinary and plasma clearances, as well as their volumes of distribution, were measured during seven 30-min periods after a 90-min equilibrium time. RESULTS: Mean age was 52.2 ± 14.5 years, 59% were men. Urinary clearances of 51Cr-EDTA and 99mTc-DTPA were 64.1 ± 27.6 and 66.1 ± 28.0 mL/min, respectively, with a mean bias of 2.00 ± 2.25 mL/min, an accuracy within 10% of 95% [95% CI 91-99], and a coefficient of determination (R2) of 0.994. Plasma clearances of 51Cr-EDTA and 99mTc-DTPA were 66.1 ± 25.8 and 68.1 ± 26.6 mL/min, respectively, with a mean bias of 1.96 ± 3.32 mL/min, an accuracy within 10% of 91% [95% CI 85-97] and a R2 of 0.985. Distribution volumes were 17.3 ± 4.6 L for 51Cr-EDTA and 16.6 ± 4.6 L for 99mTc-DTPA (R2 0.930). CONCLUSION: The accuracy and precision of 99mTc-DTPA clearance, compared to 51Cr-EDTA clearance, was excellent for both urinary and plasma clearance methods, despite an approximate 2 mL/min overestimation, showing that the tracer is a reliable alternative to 51Cr-EDTA for GFR measurement.


Subject(s)
Technetium Tc 99m Pentetate , Technetium , Edetic Acid , Glomerular Filtration Rate , Humans , Male , Middle Aged , Prospective Studies
3.
Eur J Hosp Pharm ; 27(3): 162-167, 2020 05.
Article in English | MEDLINE | ID: mdl-32419937

ABSTRACT

Background: Given the importance of surgical debridement in healing of diabetic foot ulcers, effective local anaesthesia is required to manage the related extreme pain. The pharmaceutical proprietary products currently available have low concentrations and do not exceed 5% w/w local anaesthetic. Objective: Formulation design of a lidocaine cream of 25% and assessment of the intrinsic stability. Methods: A cream pharmaceutical form was chosen for its ability to cross the skin barrier and effectively anaesthetise the skin. The choice of cream formula is based on changes in the size of the emulsions and resistance to physical stress. Stability tests were assessed over a 6-month period in terms of physical (evaluation of oil droplets), microbiological (germ count and identification, and preservative antimicrobial efficacy) and chemical parameters (content and pH). Results: Under the study conditions, the drug product displayed good physicochemical and microbiological stability for 6 months at 20°C and 40°C, and no degradation product was detected. Due to the systemic adverse effects of lidocaine, the pH stability guarantee the drug product tolerance along with very weak systemic passage. Conclusions: Given the good physicochemical and microbiological stability of the drug product over 6-month period, it has been made available to the clinical unit. An average of 250 patients per year benefit from the treatment with an excellent efficacy/tolerability ratio.


Subject(s)
Anesthetics, Local/administration & dosage , Chemistry, Pharmaceutical/methods , Drug Compounding/methods , Lidocaine/administration & dosage , Administration, Cutaneous , Anesthetics, Local/chemistry , Diabetic Foot/drug therapy , Drug Stability , Drug Storage , Humans , Hydrogen-Ion Concentration , Lidocaine/chemistry , Pain/drug therapy , Skin Cream , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...