Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Cardiol ; 129: 25-29, 2020 08 15.
Article in English | MEDLINE | ID: mdl-32600783

ABSTRACT

Occult atrial fibrillation (AF) can be the underlying cause for cryptogenic stroke (CS). Implantable loop recorders (ILRs) have become an important tool for long-term arrhythmia monitoring in CS patients. Office-based ILR implantation by nonelectrophysiologist physicians is increasingly common. To report the real world diagnostic yield and accuracy of remote ILR monitoring in high risk CS patients, we retrospectively analyzed 145 consecutive patients with CS who underwent ILR implantation between October 2014 and October 2018 at New York University Langone Health. A certified device technician and an electrophysiologist adjudicated all transmissions. The yield and accuracy of Reveal LINQ Intra Cardiac Monitor (ICM), a fourth generation device, was compared to that of TruRhythm Detection algorithm (fifth generation device). AF was diagnosed in 17 patients (12%) over a mean follow-up of 28 ± 12 months. The median time to diagnosis was 7.4 ± 21.3 months. A total of 1,637 remote transmissions (scheduled- and auto-triggered alerts: 756; patient-triggered: 881) were adjudicated. The positive predictive value for AF episodes in the scheduled interrogations increased from 4% in the Reveal LINQ ICM to 16% in the TruRhythm LINQ. Of 881 patient-triggered transmissions, none were found to be true positive. In the Reveal LINQ ICM, for scheduled transmissions, primary causes of false positive (FP) were atrial ventricular premature complexes (80%). In the TruRhythm LINQ, for scheduled transmissions, primary cause of FP were T-wave over-sensing (87%). In conclusion, the real world diagnostic yield of ILR for patients with CS remains suboptimal, with at least 84% of AF alerts being FP. Patient-riggered events did not correlate with arrhythmia and the necessity of patient triggering in this population should be questioned. Expert interpretation of recordings is critical to assure accurate diagnosis.


Subject(s)
Algorithms , Atrial Fibrillation/diagnosis , Electrocardiography, Ambulatory/methods , Prostheses and Implants , Stroke/etiology , Aged , Aged, 80 and over , Atrial Fibrillation/complications , Electrocardiography, Ambulatory/instrumentation , Female , Humans , Male , Middle Aged , Retrospective Studies
3.
JACC Case Rep ; 2(8): 1166-1169, 2020 Jul.
Article in English | MEDLINE | ID: mdl-34317440

ABSTRACT

Conducted energy weapon (commonly known as TASER) discharge in patients with implantable cardioverter-defibrillators is known to cause electromagnetic interference and inappropriate ventricular fibrillation sensing without delivery of implantable cardioverter-defibrillators therapy during conducted energy weapon application. We report the first known case of conducted energy weapon discharge resulting in inappropriate implantable cardioverter-defibrillators therapy. (Level of Difficulty: Beginner.).

SELECTION OF CITATIONS
SEARCH DETAIL
...