Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Anesth ; 19(6): 476-8, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17967682

ABSTRACT

Fetal oxygen saturation (FSpo(2)) is an emerging technology for intrapartum fetal monitoring. We monitored FSpo(2) before and after combined spinal-epidural analgesia in 8 laboring women requesting neuraxial analgesia. Fetal heart rate (FHR) and FSpo(2) (using the Nellcor N400/FS14 system [Nellcor, Pleasanton, CA]) were recorded at baseline and every minute for 45 minutes after analgesia. We observed no significant changes in FSpo(2) after analgesia (mean DeltaFSpo(2) 2 +/- 7 %, P = 0.46). Fetal oxygen saturation at baseline and after analgesia was 53% +/- 9% and 51% +/- 8%, respectively. We observed no significant FHR changes or any fetal bradycardia following combined spinal-epidural analgesia.


Subject(s)
Analgesia, Epidural , Analgesia, Obstetrical , Anesthesia, Spinal , Fetal Blood/chemistry , Fetal Monitoring , Oxygen/blood , Female , Heart Rate, Fetal , Humans , Pregnancy
2.
Anesthesiology ; 103(3): 606-12, 2005 Sep.
Article in English | MEDLINE | ID: mdl-16129987

ABSTRACT

BACKGROUND: The ideal intrathecal isobaric bupivacaine dose for cesarean delivery anesthesia is uncertain. While small doses (5-9 mg) of bupivacaine may reduce side effects such as hypotension, they potentially increase spinal anesthetic failures. This study determined the ED50 and ED95 of intrathecal isobaric bupivacaine (with adjuvant opioids) for cesarean delivery. METHODS: After institutional review board approval and written informed consent were obtained, 48 parturients undergoing elective cesarean delivery under combined spinal-epidural anesthesia were enrolled in this double-blind, randomized, dose-ranging study. Patients received a 5-, 6-, 7-, 8-, 9-, 10-, 11-, or 12-mg intrathecal isobaric bupivacaine dose with 10 microg fentanyl and 200 microg morphine. Overall anesthetic success was recorded when no intraoperative epidural supplement was required during the cesarean delivery. ED50 and ED95 values for overall anesthetic success were determined using a logistic regression model. RESULTS: ED50 and ED95 values for overall anesthetic success were 7.25 and 13.0 mg, respectively. No advantages for low doses could be demonstrated with regard to hypotension, nausea, vomiting, pruritus, or maternal satisfaction, although this study was underpowered to detect significant differences in secondary outcome variables. CONCLUSIONS: The ED50 and ED95 values (7.25 and 13.0 mg, respectively) for intrathecal isobaric bupivacaine in this circumstance are similar to values the authors determined recently for hyperbaric bupivacaine using similar methodology. These ED50 and ED95 values are significantly higher than those advocated in previous reports in which success was claimed using lower intrathecal bupivacaine doses. The current study used stricter criteria to define "successful" anesthesia and support the use of larger bupivacaine doses to ensure adequate patient comfort.


Subject(s)
Anesthesia, Obstetrical , Bupivacaine/administration & dosage , Cesarean Section , Fentanyl/administration & dosage , Morphine/administration & dosage , Adult , Bupivacaine/adverse effects , Double-Blind Method , Female , Humans , Injections, Spinal , Logistic Models , Pregnancy , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...