Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Kidney J ; 13(2): 261-262, 2020 Apr.
Article in English | MEDLINE | ID: mdl-32296530

ABSTRACT

We report a case of anti-glomerular basement membrane (GBM) disease in association with human leucocyte antigen (HLA) DRB1 15:01. A 71-year-old woman presented with oligoanuric acute kidney injury accompanied by high titre anti-GBM antibodies. Renal biopsy revealed a severe crescentic glomerulonephritis. Her brother had presented 6 years earlier with oligoanuric acute kidney injury. He was dual positive for MPO ANCA and anti-GBM antibodies. Renal biopsy was not performed. Both had an absence of pulmonary involvement. Tissue typing confirmed both were heterozygous for HLA DRB1 15:01 and DRB1 04:03.

2.
Perit Dial Int ; 33(5): 544-51, 2013.
Article in English | MEDLINE | ID: mdl-23547279

ABSTRACT

BACKGROUND: The optimal approach to monitoring blood pressure (BP) in the peritoneal dialysis (PD) population is unclear. Ambulatory BP monitoring reliably predicts prognosis, but can be inconvenient. The accuracy of home BP monitoring in this population is unproven. The automated BpTRU device (BpTRU Medical Devices, Coquitlam, BC, Canada), which provides an average of up to 6 successive in-office BP measurements, has not been studied in this patient group. METHODS: We studied 17 patients (average age: 54 ± 12 years; 12 men, 5 women; 94% on automated PD) attending a single center. All patients underwent office, home, BpTRU, and ambulatory BP measurement. The reference standard for analysis was daytime ambulatory BP. Correlation between the referent method and each comparator method was determined (Pearson correlation coefficient), and Bland-Altman scatter plots depicting the differences in the BP measurements were constructed. RESULTS: Mean office BP (126.4 ± 16.9/78.8 ± 11.6 mmHg) and BpTRU BP (123.8 ± 13.7/80.7 ± 11.1 mmHg) closely approximated mean daytime ambulatory BP (129.3 ± 14.8/78.2 ± 7.9 mmHg). Mean home BP (143.8 ± 15.0/89.9 ± 28.1 mmHg) significantly overestimated mean daytime systolic BP by 14.2 mmHg (95% confidence interval: 4.3 mmHg to 24.1 mmHg; p = 0.008). Bland-Altman plots demonstrated poorest agreement between home BP and daytime ambulatory BP. No patient had "white-coat hypertension," and only 1 patient had false-resistant hypertension. Most patients showed abnormal nocturnal dipping patterns (non-dipping: n = 11; reverse-dipping: n = 5; normal dipping: n = 1). CONCLUSIONS: We report a novel finding that BP measurement using the BpTRU device is more accurate than home BP measurement in a PD population. Potential explanations for this observation include poor home BP measurement technique, use of poorly validated home BP measurement devices, or a reduced prevalence of white-coat effect among PD patients. Our study also confirms that, in the PD population, BP measurements vary considerably with patient location, time of day, and measurement technique.


Subject(s)
Blood Pressure Monitoring, Ambulatory/instrumentation , Blood Pressure , Hypertension/diagnosis , Peritoneal Dialysis/adverse effects , Cross-Sectional Studies , Equipment Design , Female , Follow-Up Studies , Humans , Hypertension/epidemiology , Hypertension/etiology , Ireland/epidemiology , Male , Middle Aged , Prevalence , Prognosis , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...