Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
JSES Int ; 8(2): 282-286, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38464451

ABSTRACT

Background: To compare the complications and efficacy of pain relief of the interscalene anesthetic block using either a single-injection (SI) vs. a continuous, indwelling catheter (CIC) for arthroscopic rotator cuff repair surgery. Methods: Patients undergoing primary, arthroscopic rotator cuff repair without concomitant open procedure or biceps tenodesis were prospectively enrolled by 4 fellowship-trained sports medicine and shoulder surgeons. Patients received either a SI or CIC preoperatively based on surgeon preference. Patients were contacted by phone to complete a standard questionnaire on postoperative days (PODs) 1, 3, 7, 14, and 28. Patients were asked to rate the efficacy of their subjective pain relief (scale of 0-10), document issues with the catheter, describe analgesic usage, and report pharmacological and medical complications. The primary outcome was measured as complication rate. Postoperative narcotic use, patient satisfaction, and visual analog scale pain scores were measured as secondary outcomes. Results: Seventy patients were enrolled, 33 CIC patients (13 male, 20 female, mean age 61 ± 8 years) and 37 SI patients (20 male, 17 female, mean age 59 ± 10 years). There were significantly more injection/insertion site complications in the CIC group (48%) vs. the SI group (11%, P = .001). The incidence of motor weakness was higher in the CIC group on POD 1 (P = .034), but not at any subsequent time points. On POD 1, CIC patients had a clinically significantly lower pain score compared to SI (3.2 vs. 5.4; P = .020). Similar scores were observed at subsequent time points until POD 28, when CIC again had a lower pain score (0.8 vs. 2.7; P = .005). However, this did not reach clinical significance. All patients in both groups rated a satisfaction of 9 or 10 (scale 0-10) with the anesthesia provided by their nerve block. Conclusion: CIC interscalene nerve blocks had an increased risk for injection site complications and minor complications in the immediate postoperative period when using the CIC for arthroscopic rotator cuff repair without any concomitant open procedures. CIC blocks demonstrated clinically significant superior pain relief on POD 1 but were equal to SI blocks at every time point thereafter. Superior pain relief of CIC at POD 28 was not clinically significant. CIC catheters do not appear to markedly decrease the use of postoperative narcotics. Despite this trend in complication rates and pain scores, all patients in both groups were satisfied with their nerve block.

2.
JBJS Case Connect ; 5(2): e49, 2015.
Article in English | MEDLINE | ID: mdl-29252703

ABSTRACT

CASE: An extensive iliofemoral-popliteal deep venous thrombosis following arthroscopic anterior cruciate ligament reconstruction presented on the ninth postoperative day as the result of underlying May-Thurner syndrome. The patient was managed with therapeutic anticoagulation and mechanical disruption of the thrombus. The focal stenosis of the left common iliac vein was addressed with angioplasty and stent placement. Repeat venography demonstrated no residual stenosis of the vein. CONCLUSION: A multidisciplinary approach remains necessary for treating and reducing the risk of post-thrombotic syndrome. The present case further emphasizes the need for aggressive workup and response when a patient presents with left-sided deep venous thrombosis associated with underlying May-Thurner syndrome.

3.
J Biomech Eng ; 134(8): 081007, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22938360

ABSTRACT

Radio frequency energy (RFE) thermal chondroplasty has been a widely-utilized method of cartilage debridement in the past. Little is known regarding its effect on tissue mechanics. This study investigated the acute biomechanical effects of bipolar RFE treatment on human chondromalacic cartilage. Articular cartilage specimens were extracted (n = 50) from femoral condyle samples of patients undergoing total knee arthroplasty. Chondromalacia was graded with the Outerbridge classification system. Tissue thicknesses were measured using a needle punch test. Specimens underwent pretreatment load-relaxation testing using a spherical indenter. Bipolar RFE treatment was applied for 45 s and the indentation protocol was repeated. Structural properties were derived from the force-time data. Mechanical properties were derived using a fibril-reinforced biphasic cartilage model. Statistics were performed using repeated measures ANOVA. Cartilage thickness decreased after RFE treatment from a mean of 2.61 mm to 2.20 mm in Grade II, II-III, and III specimens (P < 0.001 each). Peak force increased after RFE treatment from a mean of 3.91 N to 4.91 N in Grade II and III specimens (P = 0.002 and P = 0.003, respectively). Equilibrium force increased after RFE treatment from a mean of 0.236 N to 0.457 N (P < 0.001 each grade). Time constant decreased after RFE treatment from a mean of 0.392 to 0.234 (P < 0.001 for each grade). Matrix modulus increased in all specimens following RFE treatment from a mean 259.12 kPa to 523.36 kPa (P < 0.001 each grade). Collagen fibril modulus decreased in Grade II and II-III specimens from 60.50 MPa to 42.04 MPa (P < 0.001 and P = 0.005, respectively). Tissue permeability decreased in Grade II and III specimens from 2.04 ∗10(-15) m(4)/Ns to 0.91 ∗10(-15) m(4)/Ns (P < 0.001 and P = 0.009, respectively). RFE treatment decreased thickness, time constant, fibril modulus, permeability, but increased peak force, equilibrium force, and matrix modulus. While resistance to shear and tension could be compromised due to removal of the superficial layer and decreased fibril modulus, RFE treatment increases matrix modulus and decreases tissue permeability which may restore the load- bearing capacity of the cartilage.


Subject(s)
Arthroplasty, Replacement, Knee , Cartilage, Articular/radiation effects , Cartilage, Articular/surgery , Mechanical Phenomena , Radio Waves , Temperature , Aged , Aged, 80 and over , Biomechanical Phenomena , Cartilage, Articular/metabolism , Collagen/metabolism , Female , Hardness Tests , Humans , Male , Middle Aged , Permeability/radiation effects
SELECTION OF CITATIONS
SEARCH DETAIL
...