1.
J Struct Biol ; 161(3): 352-8, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18054249

ABSTRACT

A prototype direct detection device (DDD) camera system has shown great promise in improving both the spatial resolution and the signal to noise ratio for electron microscopy at 120-400 keV beam energies (Xuong et al., 2007. Methods in Cell Biology, 79, 721-739). Without the need for a resolution-limiting scintillation screen as in the charge coupled device (CCD), the DDD camera can outperform CCD based systems in terms of spatial resolution, due to its small pixel size (5 microm). In this paper, the modulation transfer function (MTF) of the DDD prototype is measured and compared with the specifications of commercial scientific CCD camera systems. Combining the fast speed of the DDD with image mosaic techniques, fast wide-area imaging is now possible. In this paper, the first large area mosaic image and the first tomography dataset from the DDD camera are presented, along with an image processing algorithm to correct the specimen drift utilizing the fast readout of the DDD system.


Subject(s)
Image Processing, Computer-Assisted/methods , Microscopy, Electron, Transmission/instrumentation , Microscopy, Electron, Transmission/methods
3.
Ultramicroscopy ; 104(2): 152-9, 2005 Sep.
Article in English | MEDLINE | ID: mdl-15890445

ABSTRACT

A new high-resolution recording device for transmission electron microscopy (TEM) is urgently needed. Neither film nor CCD cameras are systems that allow for efficient 3-D high-resolution particle reconstruction. We tested an active pixel sensor (APS) array as a replacement device at 200, 300, and 400 keV using a JEOL JEM-2000 FX II and a JEM-4000 EX electron microscope. For this experiment, we used an APS prototype with an area of 64 x 64 pixels of 20 microm x 20 microm pixel pitch. Single-electron events were measured by using very low beam intensity. The histogram of the incident electron energy deposited in the sensor shows a Landau distribution at low energies, as well as unexpected events at higher absorbed energies. After careful study, we concluded that backscattering in the silicon substrate and re-entering the sensitive epitaxial layer a second time with much lower speed caused the unexpected events. Exhaustive simulation experiments confirmed the existence of these back-scattered electrons. For the APS to be usable, the back-scattered electron events must be eliminated, perhaps by thinning the substrate to less than 30 microm. By using experimental data taken with an APS chip with a standard silicon substrate (300 microm) and adjusting the results to take into account the effect of a thinned silicon substrate (30 microm), we found an estimate of the signal-to-noise ratio for a back-thinned detector in the energy range of 200-400 keV was about 10:1 and an estimate for the spatial resolution was about 10 microm.


Subject(s)
Microscopy, Electron/instrumentation , Microscopy, Electron/methods , Silicon , Cryoelectron Microscopy/instrumentation , Cryoelectron Microscopy/methods , Electrons , Image Processing, Computer-Assisted/instrumentation , Image Processing, Computer-Assisted/methods , Microchip Analytical Procedures