Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Publication year range
1.
Eur J Surg Oncol ; 39(5): 409-16, 2013 May.
Article in English | MEDLINE | ID: mdl-23465183

ABSTRACT

BACKGROUND: Currently, due to progress in detection and to extended screening, surgeons have to deal with increasing numbers of non-palpable lesions in breast cancer. These lesions can be treated by radio-guided surgery in the lumpectomy associated with sentinel lymph node (SLN) procedures. Thanks to advances in detector technology, mini gamma cameras are now available, that can perform real-time lymphoscintigraphy during surgery, or at bedside. AIM: In this article, we review the clinical literature on these dedicated cameras used in breast cancer surgery. The goal is to show how these cameras are used in breast cancer treatment and in SLN biopsy and what kind of benefits they offer. METHODS: We conducted our search on MEDLINE and EMBASE databases. We performed a comprehensive review to identify clinical studies or cases using mobile gamma cameras in breast cancer surgery. RESULTS: We collected 14 articles published between January 2000 and March 2012. We analysed the use of the mobile cameras and the obtained results. CONCLUSION: Mobile gamma cameras seem to be useful imaging tools either used pre-operatively or during surgery. They assist surgeons with accurate localization of SLNs and/or radio-labelled tumours, and in verification that all radioactive nodes have been excised.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Gamma Cameras , Point-of-Care Systems , Female , Humans , Lymph Node Excision/methods , Lymphatic Metastasis/diagnostic imaging , Lymphoscintigraphy , Miniaturization , Sentinel Lymph Node Biopsy/methods
2.
Gynecol Obstet Fertil ; 40(12): 772-5, 2012 Dec.
Article in French | MEDLINE | ID: mdl-23165225

ABSTRACT

Non-palpable breast cancers are more and more frequent. Their surgical management requires the excision of the tumor and sentinel lymph node (SLN) needing a technical preoperative organization combining preoperative identification of the tumor by wire guide and injection of a radioactive tracer for the identification of SLN. The implementation of this minimally invasive surgery is sometimes paradoxically complicated due to the presurgical organization requiring several medical teams. It is for this reason that hand-held gamma-cameras have been developed, used either preoperatively or during surgery to replace lymphoscintigraphy but also as a help to excision of the tumor after radioisotope injection. The objective of this study was to evaluate the interest of the main hand-held gamma-cameras used in breast cancer.


Subject(s)
Breast Neoplasms/surgery , Gamma Cameras , Radioisotopes , Breast Neoplasms/pathology , Female , Humans , Lymph Nodes/pathology , Palpation , Sentinel Lymph Node Biopsy/methods
3.
Phys Med Biol ; 54(14): 4439-53, 2009 Jul 21.
Article in English | MEDLINE | ID: mdl-19556688

ABSTRACT

The survival outcome of patients suffering from gliomas is directly linked to the complete surgical resection of the tumour. To help the surgeons to delineate precisely the boundaries of the tumour, we developed an intraoperative positron probe with background noise rejection capability. The probe was designed to be directly coupled to the excision tool such that detection and removal of the radiolabelled tumours could be simultaneous. The device consists of two exchangeable detection heads composed of clear and plastic scintillating fibres. Each head is coupled to an optic fibre bundle that exports the scintillating light to a photodetection and processing electronic module placed outside the operative wound. The background rejection method is based on a real-time subtraction technique. The measured probe sensitivity for (18)F was 1.1 cps kBq(-1) ml(-1) for the small head and 3.4 cps kBq(-1) ml(-1) for the large head. The mean spatial resolution was 1.6 mm FWHM on the detector surface. The gamma-ray rejection efficiency measured by realistic brain phantom modelling of the surgical cavity was 99.4%. This phantom also demonstrated the ability of the probe to detect tumour discs as small as 5 mm in diameter (20 mg) for tumour-to-background ratios higher than 3:1 and with an acquisition time around 4 s at each scanning step. These results indicate that our detector could be a useful complement to existing techniques for the accurate excision of brain tumour tissue and more generally to improve the efficiency of radio-guided cancer surgery.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Image Enhancement/instrumentation , Positron-Emission Tomography/instrumentation , Surgery, Computer-Assisted/instrumentation , Transducers , Equipment Design , Equipment Failure Analysis , Humans , Miniaturization , Reproducibility of Results , Sensitivity and Specificity , Systems Integration
5.
Electrophoresis ; 22(16): 3527-32, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11669537

ABSTRACT

We describe an original apparatus for the study of the dynamics of single stranded DNA migration. Four detectors based on laser-induced fluorescence (LIF) are equidistantly placed on one migration lane, allowing repeated measurements of the same DNA band at different positions along migration. This article presents the characteristics and performances of this system and focuses on the data analysis, showing how the multiple detection scheme enables the study of band broadening and band resolution during a migration run. Our results suggest the existence of anomalous (nonthermal) diffusion of DNA molecules during the electrophoretic process.


Subject(s)
Bacteriophage M13/genetics , DNA, Single-Stranded/chemistry , DNA, Viral/chemistry , Electrophoresis, Polyacrylamide Gel/instrumentation , Electrophoresis, Polyacrylamide Gel/methods , Nucleic Acid Denaturation , Time Factors
6.
J Chromatogr A ; 894(1-2): 231-9, 2000 Oct 13.
Article in English | MEDLINE | ID: mdl-11100865

ABSTRACT

An original apparatus based on laser-induced fluorescence detection is presented. One lane migration combined to four equidistant detection points allows the study of the dynamics of DNA bands during electrophoresis. We focus this article on the study of the mobility of DNA sequencing fragments as a function of temperature; mobility is determined in 4% T, 5% C and 4.3% T, 5% C cross-linked polyacrylamide gels at an electric field of 45 V/cm [T=(g acrylamide+g N,N'-methylenebisacrylamide)/100 ml solution; C=g N,N'-methylenebisacrylamide/% T]. Activation energy has been investigated under these experimental conditions with a temperature varying from 25 to 50 degrees C. The activation energy for migration through the cross-linked polyacrylamide gel decreases with fragment length under our experimental conditions and it varies along the migration.


Subject(s)
DNA, Single-Stranded/chemistry , Electrophoresis, Polyacrylamide Gel/methods
7.
J Chem Ecol ; 20(12): 3321-34, 1994 Dec.
Article in English | MEDLINE | ID: mdl-24241995

ABSTRACT

Behavioral responses of the gastropod molluscLittoraria (=Littorina)irrorata indicate that it can discriminate among environmental odors. Snails were assayed for responses to 11 odors from plants and animals potentially representing food, shelter, location in the environment, and predators. Crushed conspecifics were included as an alarm odor. Except for odor of crushed conspecifics, all odor sources were water-borne from living intact organisms. Behavioral responses were categorized as no response, positive response, or negative response. For some analyses, negative responses were subdivided into withdrawing and turning responses. Snails responded positively to several plant odors. They did not respond to odors of intact conspecifics, fiddler crabs, or grass shrimp. They responded negatively to odors of a plant found at the upper limit of their minimal habitat, predatory blue crabs, crushed conspecifics, predatory gastropods, and ribbed mussels. Odors of blue crabs on different diets affect the type of negative response the snails display.

SELECTION OF CITATIONS
SEARCH DETAIL
...