Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters











Database
Language
Publication year range
1.
Indian J Crit Care Med ; 18(7): 431-6, 2014 Jul.
Article in English | MEDLINE | ID: mdl-25097355

ABSTRACT

BACKGROUND AND OBJECTIVES: Patients on mechanical ventilation in intensive care unit (ICU) are often uncomfortable because of anxiety, pain, and endotracheal intubation; therefore, require sedation. Alpha-2 agonists are known to produce sedation. We compared clonidine and dexmedetomidine as sole agents for sedation. STUDY DESIGN: Prospective, randomized, controlled open-label study. MATERIALS AND METHODS: A total of 70 patients requiring a minimum of 12 h of mechanical ventilation with concomitant sedation, were randomly allocated into two groups. Group C (n = 35) received intravenous (IV) clonidine (1 µg/kg/h titrated up to 2 µg/kg/h to attain target sedation), and Group D (n = 35) received IV dexmedetomidine for sedation (loading 0.7 µg/kg and maintenance 0.2 µg/kg/h titrated up to 0.7 µg/kg/h to achieve target sedation). A Ramsay Sedation Score of 3-4 was considered as target sedation. Additional sedation with diazepam was given when required to achieve target sedation. The quality of sedation, hemodynamic changes and adverse effects were noted and compared between the two groups. RESULTS: Target sedation was achieved in 86% observations in Group D and 62% in Group C (P = 0.04). Additional sedation was needed by more patients in Group C compared with Group D (14 and 8 in Groups C and D, respectively, P = 0.034), mainly due to concomitant hypotension on increasing the dose of clonidine. Hypotension was the most common side-effect in Group C, occurring in 11/35 patients of Group C and 3/35 patients of Group D (P = 0.02). Rebound hypertension was seen in four patients receiving clonidine, but none in receiving dexmedetomidine. CONCLUSION: Both clonidine and dexmedetomidine produced effective sedation; however, the hemodynamic stability provided by dexmedetomidine gives it an edge over clonidine for short-term sedation of ICU patients.

3.
Indian J Anaesth ; 57(3): 276-81, 2013 May.
Article in English | MEDLINE | ID: mdl-23983287

ABSTRACT

BACKGROUND: The Truview EVO2(C) laryngoscope (TL) is a recently introduced optical device designed to provide an unmagnified anterior image of the glottic opening and allow indirect laryngoscopy. AIM: This study is designed to determine whether the TL is a better alternative to the Macintosh laryngoscope (ML) for routine endotracheal intubations in patients with usual airway characteristics. METHODS: We compared the Truview EVO2(C) and MLs in 140 elective surgical patients requiring general anaesthesia and intubation in a prospective crossover fashion. The two blades were compared in terms of Cormack and Lehane grades, time required for intubation, anaesthetists' assessment of ease of intubation, intubation difficulty score, attempts at intubation, success rate, soft tissue damage and arterial oxygen saturation during laryngoscopy. The Student t test and Chi-square test were used to determine the statistical significance of parametric data and categorical data, respectively. RESULTS: The Truview EVO2(C) blade provided a better laryngoscopic view than the Macintosh blade as suggested by improved Cormack and Lehane grades (in 48 patients), but required a longer time for intubation than the Macintosh blade (34.1 vs. 22.4 s), i.e., an improved view at the cost of longer mean intubation time. In spite of lower intubation difficulty scores, Truview EVO2(C) was considered as difficult to use on subjective assessment by the anaesthesiologist when compared with Macintosh. There was no difference observed between the two groups in attempts at intubation, success rate, soft tissue damage and arterial oxygen saturation during laryngoscopy. CONCLUSION: We opine that although Truview provides a better laryngoscopic view than Macintosh in difficult cases, it does not have an extra benefit over Macintosh otherwise, further indicating the need for more experience with the use of a Truview laryngoscope.

4.
J Nat Sci Biol Med ; 4(1): 262-4, 2013 Jan.
Article in English | MEDLINE | ID: mdl-23633880

ABSTRACT

Symmetric peripheral gangrene is rare and relatively uncommon complication of malaria. We report a case of a 50-year-old male who survived Plasmodium falciparum infection with disseminated intravascular coagulation. Symmetric peripheral gangrene in our case, which ultimately required amputation of the toes, was most likely due to interaction between parasitic factors and host factors.

5.
Case Rep Anesthesiol ; 2013: 716756, 2013.
Article in English | MEDLINE | ID: mdl-23573425

ABSTRACT

Pycnodysostosis (the Toulouse-Lautrec syndrome) is a rare autosomal-recessive disorder of osteoclast dysfunction. This disorder was first described by Maroteaux and Lamy in 1962. We describe anaesthetic management of a 35-year-old female having pyknodysostosis with fracture shaft left femur with anticipated difficult intubation. Therefore, spinal anesthesia was planned for her fracture fixation. The intra- and postoperative period remains uneventful.

SELECTION OF CITATIONS
SEARCH DETAIL