Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
J Allergy Clin Immunol Pract ; 8(2): 635-644, 2020 02.
Article in English | MEDLINE | ID: mdl-31568927

ABSTRACT

BACKGROUND: Guidelines recommend that patients treated with inhalers receive adherence counseling and device training. Digital technologies that assess both inhaler adherence and technique have been developed. Using these technologies community pharmacists, who have regular contact with patients, are well placed to deliver personalized inhaler education. OBJECTIVE: To determine the impact of a pharmacist intervention, informed by digital technology, on inhaler technique and adherence of patients with asthma in the community. METHODS: A cluster randomized, parallel-group, multisite pharmacy study was conducted over 6 months. All study groups had an electronic device (inhaler compliance assessment device) attached to their maintenance inhaler. A biofeedback group received personalized inhaler training informed by data recorded by the device. The demonstration group received inhaler training, by physical demonstration with a placebo inhaler. The control group received usual care. The primary outcome was inhaler adherence, which was classified as "actual adherence" and expressed as the proportion of expected drug accumulation if adherence and technique had been perfect. Secondary outcomes were quality-of-life scores as measured by the St George's Respiratory Questionnaire, symptoms, and exacerbations. RESULTS: A total of 152 participants (n = 74 biofeedback, n = 56 demonstration, and n = 22 control) were recruited. Asthma was the predominant condition among participants (n = 83), with chronic obstructive pulmonary disease (n = 55) and asthma/chronic obstructive pulmonary disease overlap also reported (n = 8). In intention-to-treat analysis, adherence in the biofeedback group during month 2 was 62%, 18% higher (95% CI, 6 to 30) than that in the demonstration group (P = .004) and 24% higher (95% CI, 9 to 40) than that in the control group (P = .003). During month 6, adherence was 14% higher (95% CI, -1 to 30; P = .07) in the biofeedback group than in the demonstration group and 31% higher (95% CI, 13 to 48; P = .001) than in the control group. At the end of the study, the biofeedback group had a sustained fall in St George's Respiratory Questionnaire from baseline, -6.1 (95% CI, -9 to -0.4; P = .04) and had significantly improved daily respiratory symptoms. CONCLUSIONS: Community pharmacist-delivered inhaler training informed by a digital technology improved adherence and health status.


Subject(s)
Pharmacists , Pulmonary Disease, Chronic Obstructive , Administration, Inhalation , Biofeedback, Psychology , Humans , Medication Adherence , Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive/drug therapy , Quality of Life
2.
BMC Public Health ; 19(1): 1698, 2019 Dec 18.
Article in English | MEDLINE | ID: mdl-31852470

ABSTRACT

BACKGROUND: Despite the existence of efficacious vaccines, the burden of vaccine-preventable diseases remains high and the potential health benefits of paediatric, adolescent and adult vaccination are not being achieved due to suboptimal vaccine coverage rates. Based on emerging evidence that pharmacy-based vaccine interventions are feasible and effective, the European Interdisciplinary Council for Ageing (EICA) brought together stakeholders from the medical and pharmacy professions, the pharmaceutical industry, patient/ageing organisations and health authorities to consider the potential for pharmacy-based interventions to increase vaccine uptake. We report here the proceedings of this 3-day meeting held in March 2018 in San Servolo island, Venice, Italy, focussing firstly on examples from countries that have introduced pharmacy-based vaccination programmes, and secondly, listing the barriers and solutions proposed by the discussion groups. CONCLUSIONS: A range of barriers to vaccine uptake have been identified, affecting all target groups, and in various countries and healthcare settings. Ease of accessibility is a potentially modifiable determinant in vaccine uptake, and thus, improving the diversity of settings where vaccines can be provided to adults, for example by enabling community pharmacists to vaccinate, may increase the number of available opportunities for vaccination.


Subject(s)
Health Promotion/methods , Patient Acceptance of Health Care/psychology , Patient Acceptance of Health Care/statistics & numerical data , Pharmaceutical Services/organization & administration , Pharmacists , Vaccination/psychology , Vaccination/statistics & numerical data , Adult , Congresses as Topic , Europe , Female , Humans , Italy , Male , Middle Aged , Organizational Objectives , Professional Role
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 2606-2609, 2019 Jul.
Article in English | MEDLINE | ID: mdl-31946430

ABSTRACT

Chronic respiratory diseases may be controlled through the delivery of medication to the airways and lungs using an inhaler. However, adherence to correct inhaler technique is poor, which impedes patients from receiving maximum clinical benefit from their medication. In this study, the Inhaler Compliance Assessment device was employed to record audio of patients using a Diskus dry powder inhaler. An algorithm that classifies inhaler sounds (blister, inhalation, interference) was developed to automatically assess patient adherence from these inhaler audio recordings. The presented algorithm employed audio-based signal processing methods and statistical modeling in the form of quadratic discriminant analysis (QDA). A total of 350 audio recordings were obtained from 70 patients. The acquired audio dataset was split evenly for training and testing. A total accuracy of 85.35% was obtained (testing dataset) for this 3-class classification system. A sensitivity of 89.22% and 70% was obtained for inhalation and blister detection respectively. This approach may have significant clinical impact by providing healthcare professionals with an efficient, objective method of monitoring patient adherence to inhaler treatment.


Subject(s)
Asthma/drug therapy , Dry Powder Inhalers , Medication Adherence , Sound , Administration, Inhalation , Algorithms , Humans , Sensitivity and Specificity
4.
J Allergy Clin Immunol Pract ; 4(5): 900-909.e2, 2016.
Article in English | MEDLINE | ID: mdl-27587321

ABSTRACT

BACKGROUND: Cross-sectional observational studies suggest that between 50% and 60% of patients misuse a dry powder inhaler, whereas studies with electronic monitors indicate that patients sometimes overuse/underuse their inhalers. It is not known what impact errors and erratic use have on inhaler adherence. OBJECTIVES: The purpose of this study was to longitudinally quantify when and how patients adhered to a twice-daily preventer treatment by using a novel acoustic recording device attached to an inhaler (INhaler Compliance Assessment). METHODS: Patients with a history of asthma or chronic obstructive pulmonary disease (n = 123) from primary care and community pharmacies were given an INhaler Compliance Assessment-adapted inhaler for 1 month. Analysis of the audio files provided quantitative information on time and technique of inhaler use. RESULTS: Data were available for 103 patients. Twenty-one patients (20%) used their inhaler in the correct manner at the correct interval. There were 5045 audio files with attempted inhalations, of which 1204 had technique errors (24%). Errors included inadequate flow (27%), drug priming without inhalation (19%), exhalation into the inhaler (18%), and multiple inhalations (25%). On average, participants made errors 20% of the time. Of 60 doses expected to be taken in a month per person, on average 49 doses (82%) were attempted and when errors were accounted for, the average number of actual doses taken was 34 doses (57%; P < .01) comparing attempted to actual doses. DISCUSSION: These data highlight that ineffective and irregular inhaler use is common and when combined in a single calculation indicate that only 20% of participants used their inhaler correctly and on time.


Subject(s)
Dry Powder Inhalers/statistics & numerical data , Medication Adherence , Acoustics , Administration, Inhalation , Adult , Aged , Aged, 80 and over , Asthma/drug therapy , Female , Humans , Male , Middle Aged , Pilot Projects , Pulmonary Disease, Chronic Obstructive/drug therapy , Young Adult
5.
Ann Am Thorac Soc ; 13(11): 1894-1903, 2016 11.
Article in English | MEDLINE | ID: mdl-27467125

ABSTRACT

RATIONALE: Currently, studies on adherence to inhaled medications report average adherence over time. This measure does not account for variations in the interval between doses, nor for errors in inhaler use. OBJECTIVES: To investigate whether adherence calculated as a single area under the (concentration-time) curve (AUC) measure, incorporating the interval between doses and inhaler technique, was more reflective of patient outcomes than were current methods of assessing adherence. METHODS: We attached a digital audio device (INhaler Compliance Assessment) to a dry powder inhaler. This recorded when the inhaler was used, and analysis of the audio data indicated if the inhaler had been used correctly. These aspects of inhaler use were combined to calculate adherence over time, as an AUC measure. Over a 3-month period, a cohort of patients with asthma was studied. Adherence to a twice-daily inhaler preventer therapy using this device and clinical measures were assessed. MEASUREMENTS AND MAIN RESULTS: Recordings from 239 patients with severe asthma were analyzed. Average adherence that was based on the dose counter was 84.4%, whereas the ratio of expected to observed accumulated AUC, actual adherence, was 61.8% (P < 0.01). Of all the adherence measures, only adherence calculated as AUC reflected changes in asthma quality of life, ß-agonist reliever use, and peak expiratory flow over the 3 months (P < 0.05 compared with other measures of adherence). CONCLUSIONS: Adherence that incorporates the interval between doses and inhaler technique, and calculated as AUC, is more reflective of changes in quality of life and lung function than are the currently used measures of adherence. Clinical trial registered with www.clinicaltrials.gov (NCT 01529697).


Subject(s)
Asthma/drug therapy , Bronchodilator Agents/therapeutic use , Medication Adherence/statistics & numerical data , Administration, Inhalation , Adult , Aged , Area Under Curve , Female , Humans , Ireland , Male , Middle Aged , Nebulizers and Vaporizers/statistics & numerical data , Prospective Studies , Quality of Life , Single-Blind Method , Treatment Outcome
6.
Trials ; 17(1): 226, 2016 May 04.
Article in English | MEDLINE | ID: mdl-27142873

ABSTRACT

BACKGROUND: Poor adherence to inhaled medication may lead to inadequate symptom control in patients with respiratory disease. In practice it can be difficult to identify poor adherence. We designed an acoustic recording device, the INCA® (INhaler Compliance Assessment) device, which, when attached to an inhaler, identifies and records the time and technique of inhaler use, thereby providing objective longitudinal data on an individual's adherence to inhaled medication. This study will test the hypothesis that providing objective, personalised, visual feedback on adherence to patients in combination with a tailored educational intervention in a community pharmacy setting, improves adherence more effectively than education alone. METHODS/DESIGN: The study is a prospective, cluster randomised, parallel-group, multi-site study conducted over 6 months. The study is designed to compare current best practice in care (i.e. routine inhaler technique training) with the use of the INCA® device for respiratory patients in a community pharmacy setting. Pharmacies are the unit of randomisation and on enrolment to the study they will be allocated by the lead researcher to one of the three study groups (intervention, comparator or control groups) using a computer-generated list of random numbers. Given the nature of the intervention neither pharmacists nor participants can be blinded. The intervention group will receive feedback from the acoustic recording device on inhaler technique and adherence three times over a 6-month period along with inhaler technique training at each of these times. The comparator group will also receive training in inhaler use three times over the 6-month study period but no feedback on their habitual performance. The control group will receive usual care (i.e. the safe supply of medicines and advice on their use). The primary outcome is the rate of participant adherence to their inhaled medication, defined as the proportion of correctly taken doses of medication at the correct time relative to the prescribed interval. Secondary outcomes include exacerbation rates and quality of life measures. Differences in the timing and technique of inhaler use as altered by the interventions will also be assessed. Data will be analysed on an intention-to-treat and a per-protocol basis. Sample size has been calculated with reference to comparisons to be made between the intervention and comparator clusters and indicates 75 participants per cluster. With an estimated 10 % loss to follow-up we will be able to show a 20 % difference between the population means of the intervention and comparator groups with a power of 0.8. The Type I error probability associated with the test of the null hypothesis is 0.05. DISCUSSION: This clinical trial will establish whether providing personalised feedback to individuals on their inhaler use improves adherence. It may also be possible to enhance the role of pharmacists in clinical care by identifying patients in whom alteration of either therapy or inhaler device is appropriate. REGISTRATION: ClinicalTrials.gov NCT02203266 .


Subject(s)
Acoustics/instrumentation , Bronchodilator Agents/administration & dosage , Community Pharmacy Services , Feedback, Psychological , Fluticasone-Salmeterol Drug Combination/administration & dosage , Glucocorticoids/administration & dosage , Lung Diseases, Obstructive/drug therapy , Medication Adherence , Nebulizers and Vaporizers , Patient Education as Topic , Administration, Inhalation , Disease Progression , Drug Administration Schedule , Equipment Design , Health Knowledge, Attitudes, Practice , Humans , Ireland , Lung Diseases, Obstructive/diagnosis , Lung Diseases, Obstructive/psychology , Prospective Studies , Quality of Life , Research Design , Time Factors , Treatment Outcome
7.
J Travel Med ; 17(6): 374-81, 2010.
Article in English | MEDLINE | ID: mdl-21050316

ABSTRACT

BACKGROUND: International travel is a potential risk factor for the spread of influenza. In the United States, approximately 5%-20% of the population develops an influenza-like illness annually. The purpose of this study was to describe the knowledge, attitude, and practices of US travelers to Asia regarding seasonal influenza and H5N1 avian influenza (AI) prevention measures. METHODS: We surveyed travelers to Asia waiting at the departure lounges of 38 selected flights at four international airports in New York, Chicago, Los Angeles, and San Francisco. Of the 1,301 travelers who completed the pre-travel survey, 337 also completed a post-travel survey. Univariate and multivariate logistic regression were used to calculate prevalence odds ratios (with 95% CI) to compare foreign-born (FB) to US-born travelers for various levels of knowledge and behaviors. RESULTS: Although the majority of participants were aware of influenza prevention measures, only 41% reported receiving the influenza vaccine during the previous season. Forty-three percent of participants reported seeking at least one type of pre-travel health advice, which was significantly higher among US-born, Caucasians, traveling for purposes other than visiting friends and relatives, travelers who received the influenza vaccine during the previous season, and those traveling with a companion. Our study also showed that Asians, FB travelers, and those working in occupations other than health care/animal care were less likely to recognize H5N1 AI transmission risk factors. CONCLUSION: The basic public health messages for preventing influenza appear to be well understood, but the uptake of influenza vaccine was low. Clinicians should ensure that all patients receive influenza vaccine prior to travel. Tailored communication messages should be developed to motivate Asians, FB travelers, those visiting friends and relatives, and those traveling alone to seek pre-travel health advice as well as to orient them with H5N1 AI risk factors.


Subject(s)
Health Behavior , Health Knowledge, Attitudes, Practice , Influenza, Human/prevention & control , Travel , Adolescent , Adult , Aged , Asia , Female , Health Surveys , Humans , Influenza A Virus, H1N1 Subtype , Influenza Vaccines/therapeutic use , Influenza, Human/etiology , Logistic Models , Male , Middle Aged , Patient Acceptance of Health Care/statistics & numerical data , Risk Factors , United States , Vaccination/statistics & numerical data , Young Adult
8.
Top Cogn Sci ; 2(3): 486-510, 2010 Jul.
Article in English | MEDLINE | ID: mdl-25163873

ABSTRACT

Inspired by the success of generative linguistics and transformational grammar, proponents of the linguistic analogy (LA) in moral psychology hypothesize that careful attention to folk-moral judgments is likely to reveal a small set of implicit rules and structures responsible for the ubiquitous and apparently unbounded capacity for making moral judgments. As a theoretical hypothesis, LA thus requires a rich description of the computational structures that underlie mature moral judgments, an account of the acquisition and development of these structures, and an analysis of those components of the moral system that are uniquely human and uniquely moral. In this paper we present the theoretical motivations for adopting LA in the study of moral cognition: (a) the distinction between competence and performance, (b) poverty of stimulus considerations, and (c) adopting the computational level as the proper level of analysis for the empirical study of moral judgment. With these motivations in hand, we review recent empirical findings that have been inspired by LA and which provide evidence for at least two predictions of LA: (a) the computational processes responsible for folk-moral judgment operate over structured representations of actions and events, as well as coding for features of agency and outcomes; and (b) folk-moral judgments are the output of a dedicated moral faculty and are largely immune to the effects of context. In addition, we highlight the complexity of the interfaces between the moral faculty and other cognitive systems external to it (e.g., number systems). We conclude by reviewing the potential utility of the theoretical and empirical tools of LA for future research in moral psychology.


Subject(s)
Cognition/ethics , Culture , Judgment/ethics , Linguistics , Morals , Humans
9.
Trends Cogn Sci ; 13(1): 1-6, 2009 Jan.
Article in English | MEDLINE | ID: mdl-19058993

ABSTRACT

Recent work in the cognitive and neurobiological sciences indicates an important relationship between emotion and moral judgment. Based on this evidence, several researchers have argued that emotions are the source of our intuitive moral judgments. However, despite the richness of the correlational data between emotion and morality, we argue that the current neurological, behavioral, developmental and evolutionary evidence is insufficient to demonstrate that emotion is necessary for making moral judgments. We suggest instead, that the source of moral judgments lies in our causal-intentional psychology; emotion often follows from these judgments, serving a primary role in motivating morally relevant action.


Subject(s)
Emotions/physiology , Morale , Socialization , Humans , Judgment , Models, Psychological
SELECTION OF CITATIONS
SEARCH DETAIL
...