1.
World Neurosurg ; 103: 600-610, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28359922

ABSTRACT

BACKGROUND: Successful endoscopic endonasal surgery for the resection of skull base tumors is reliant on preoperative imaging to delineate pathology from the surrounding anatomy. The increased signal-to-noise ratio afforded by 7-T MRI can be used to increase spatial and contrast resolution, which may lend itself to improved imaging of the skull base. In this study, we apply a 7-T imaging protocol to patients with skull base tumors and compare the images with clinical standard of care. METHODS: Images were acquired at 7 T on 11 patients with skull base lesions. Two neuroradiologists evaluated clinical 1.5-, 3-, and 7-T scans for detection of intracavernous cranial nerves and internal carotid artery (ICA) branches. Detection rates were compared. Images were used for surgical planning and uploaded to a neuronavigation platform and used to guide surgery. RESULTS: Image analysis yielded improved detection rates of cranial nerves and ICA branches at 7 T. The 7-T images were successfully incorporated into preoperative planning and intraoperative neuronavigation. CONCLUSIONS: Our study represents the first application of 7-T MRI to the full neurosurgical workflow for endoscopic endonasal surgery. We detected higher rates of cranial nerves and ICA branches at 7-T MRI compared with 3- and 1.5-T MRI, and found that integration of 7 T into surgical planning and guidance was feasible. These results suggest a potential for 7-T MRI to reduce surgical complications. Future studies comparing standardized 7-, 3-, and 1.5-T MRI protocols in a larger number of patients are warranted to determine the relative benefit of 7-T MRI for endonasal endoscopic surgical efficacy.


Subject(s)
Adenoma/diagnostic imaging , Craniopharyngioma/diagnostic imaging , Magnetic Resonance Imaging/methods , Meningeal Neoplasms/diagnostic imaging , Meningioma/diagnostic imaging , Neuroendoscopy/methods , Pituitary Neoplasms/diagnostic imaging , Skull Base Neoplasms/diagnostic imaging , Surgery, Computer-Assisted/methods , Adenoma/surgery , Adult , Craniopharyngioma/surgery , Female , Humans , Male , Meningeal Neoplasms/surgery , Meningioma/surgery , Middle Aged , Natural Orifice Endoscopic Surgery , Neuronavigation/methods , Pituitary Neoplasms/surgery , Skull Base Neoplasms/surgery
2.
Eur J Radiol Open ; 3: 1-7, 2016.
Article in English | MEDLINE | ID: mdl-27069971

ABSTRACT

PURPOSE: To correlate intra voxel incoherent motion (IVIM) diffusion parameters of liver parenchyma and hepatocellular carcinoma (HCC) with degree of liver/tumor enhancement and necrosis; and to assess the diagnostic performance of diffusion parameters vs. enhancement ratios (ER) for prediction of complete tumor necrosis. PATIENTS AND METHODS: In this IRB approved HIPAA compliant study, we included 46 patients with HCC who underwent IVIM diffusion-weighted (DW) MRI in addition to routine sequences at 3.0 T. True diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (PF) and apparent diffusion coefficient (ADC) were quantified in tumors and liver parenchyma. Tumor ER were calculated using contrast-enhanced imaging, and degree of tumor necrosis was assessed using post-contrast image subtraction. IVIM parameters and ER were compared between HCC and background liver and between necrotic and viable tumor components. ROC analysis for prediction of complete tumor necrosis was performed. RESULTS: 79 HCCs were assessed (mean size 2.5 cm). D, PF and ADC were significantly higher in HCC vs. liver (p < 0.0001). There were weak significant negative/positive correlations between D/PF and ER, and significant correlations between D/PF/ADC and tumor necrosis (for D, r 0.452, p < 0.001). Among diffusion parameters, D had the highest area under the curve (AUC 0.811) for predicting complete tumor necrosis. ER outperformed diffusion parameters for prediction of complete tumor necrosis (AUC > 0.95, p < 0.002). CONCLUSION: D has a reasonable diagnostic performance for predicting complete tumor necrosis, however lower than that of contrast-enhanced imaging.

3.
J Magn Reson Imaging ; 44(4): 856-64, 2016 10.
Article in English | MEDLINE | ID: mdl-26919327

ABSTRACT

PURPOSE: To assess the correlation between intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in hepatocellular carcinoma (HCC) and liver parenchyma. MATERIALS AND METHODS: Twenty-five patients with HCC (M/F 23/2, mean age 58 years) underwent abdominal MRI at 1.5 or 3.0T, including IVIM-DWI (with 16 b-values) and DCE-MRI (3D FLASH sequence, mean temporal resolution of 2.3 sec). IVIM-DWI parameters (pseudodiffusion coefficient, D*, diffusion coefficient, D, and perfusion fraction, PF) were quantified in HCC lesions and liver parenchyma using a Bayesian fitting algorithm. DCE-MRI parameters (arterial flow, Fa , portal flow, Fp , total flow, Ft , mean transit time, MTT, distribution volume, DV, and arterial fraction, ART) were quantified using a dual-input single-compartment model. Correlations between IVIM-DWI and DCE-MRI parameters were assessed using a Spearman correlation test. RESULTS: Thirty-three HCC lesions (average size 5.0 ± 3.6 cm) were analyzed. D, D*, and PF were all significantly lower in HCC vs. liver (P < 0.05). Significantly higher Fa and ART and lower Fp were observed in HCC vs. liver (P < 0.001). Significant moderate to strong negative correlations were observed between ART and D* (r = -0.443, P = 0.028), ART and PF (r = -0.536, P = 0.006), ART and PFxD* (r = -0.655, P < 0.001), Fa and PF (r = 0.455, P = 0.023), and Fa and PFxD* (r = -0.475, P = 0.018) in liver parenchyma. There was no significant correlation between IVIM-DWI and DCE-MRI metrics in HCC lesions. CONCLUSION: IVIM-DWI and DCE-MRI provide nonredundant information in HCC, while they correlate in liver parenchyma. These findings may be secondary to predominant portal inflow in the liver and tortuous vasculature and tissue heterogeneity in tumors. J. MAGN. RESON. IMAGING 2016;44:856-864.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Adult , Aged , Algorithms , Contrast Media , Female , Humans , Male , Middle Aged , Motion , Reproducibility of Results , Sensitivity and Specificity
4.
J Magn Reson Imaging ; 44(2): 317-26, 2016 08.
Article in English | MEDLINE | ID: mdl-26855407

ABSTRACT

PURPOSE: To assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. MATERIALS AND METHODS: Thirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI. RESULTS: ADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01). CONCLUSION: The weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Kidney Function Tests/methods , Kidney/diagnostic imaging , Kidney/physiopathology , Meglumine/analogs & derivatives , Organometallic Compounds , Adult , Aged , Algorithms , Computer Simulation , Contrast Media , Female , Humans , Image Enhancement/methods , Imaging, Three-Dimensional/methods , Male , Middle Aged , Models, Biological , Models, Statistical , Motion , Reproducibility of Results , Sensitivity and Specificity
5.
Liver Int ; 36(5): 659-66, 2016 05.
Article in English | MEDLINE | ID: mdl-26744140

ABSTRACT

BACKGROUND & AIMS: Establishing accurate non-invasive methods of liver fibrosis quantification remains a major unmet need. Here, we assessed the diagnostic value of a multiparametric magnetic resonance imaging (MRI) protocol including diffusion-weighted imaging (DWI), dynamic contrast-enhanced (DCE)-MRI and magnetic resonance elastography (MRE) in comparison with transient elastography (TE) and blood tests [including ELF (Enhanced Liver Fibrosis) and APRI] for liver fibrosis detection. METHODS: In this single centre cross-sectional study, we prospectively enrolled 60 subjects with liver disease who underwent multiparametric MRI (DWI, DCE-MRI and MRE), TE and blood tests. Correlation was assessed between non-invasive modalities and histopathologic findings including stage, grade and collagen content, while accounting for covariates such as age, sex, BMI, HCV status and MRI-derived fat and iron content. ROC curve analysis evaluated the performance of each technique for detection of moderate-to-advanced liver fibrosis (F2-F4) and advanced fibrosis (F3-F4). RESULTS: Magnetic resonance elastography provided the strongest correlation with fibrosis stage (r = 0.66, P < 0.001), inflammation grade (r = 0.52, P < 0.001) and collagen content (r = 0.53, P = 0.036). For detection of moderate-to-advanced fibrosis (F2-F4), AUCs were 0.78, 0.82, 0.72, 0.79, 0.71 for MRE, TE, DCE-MRI, DWI and APRI, respectively. For detection of advanced fibrosis (F3-F4), AUCs were 0.94, 0.77, 0.79, 0.79 and 0.70, respectively. CONCLUSIONS: Magnetic resonance elastography provides the highest correlation with histopathologic markers and yields high diagnostic performance for detection of advanced liver fibrosis and cirrhosis, compared to DWI, DCE-MRI, TE and serum markers.


Subject(s)
Biomarkers/blood , Diffusion Magnetic Resonance Imaging , Elasticity Imaging Techniques , Liver Cirrhosis/diagnostic imaging , Adult , Area Under Curve , Cross-Sectional Studies , Female , Humans , Liver/pathology , Liver Cirrhosis/blood , Logistic Models , Male , Middle Aged , New York , Prospective Studies , ROC Curve , Reproducibility of Results , Tertiary Care Centers
6.
World Neurosurg ; 86: 450-65, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26409071

ABSTRACT

BACKGROUND: Magnetic resonance imaging (MRI) is the imaging modality of choice for the clinical management of brain tumors, and the majority of scanners operate with static magnetic field strengths of 1.5 or 3.0 Tesla (T). During the past decade, ultrahigh field (UHF) MRI has been investigated for its clinical applicability. This meta-analysis evaluates studies pertaining to the application of UHF MRI to patients with brain tumors. METHODS: The authors performed a systematic review of the literature. Articles relating to application of UHF MRI to brain anatomy and brain tumors with living subjects were included. Studies were grouped into 1 of 3 categories based on area of focus: "Anatomical Structures Involved with Brain Tumors," "Tumor characterization," and "Treatment Monitoring." Comparison studies with extractable outcomes measure data were analyzed for performance of UHF MRI versus clinical field strengths (1.5 T and 3 T). RESULTS: Twenty-four studies (361 subjects) met inclusion criteria. The field of study was heterogeneous and rigorous statistical analysis was not possible. Overall, 279 patients with brain tumors scanned at UHF MRI have been reported. Of these, glioma and glioblastoma multiforme are the most commonly studied lesions (38.9% and 24.4%, respectively). In comparison studies between UHF MRI and clinical field strengths, 24 of 51 patients had outcome measures that were better with UHF MRI, 17 of 24 were equivalent at both field strengths, and 9 were worse at UHF MRI. The most common causes of a worse performance were susceptibility artifacts and magnetic field inhomogeneities (3 of 9). Imaging of the pituitary gland, pineal gland veins, cranial nerves, and tumor microvasculature were all shown to be feasible. CONCLUSIONS: UHF MRI shows promise to improve detection and characterization of brain tumors, preoperative planning for neurosurgical resection, and longitudinal monitoring of the effects of radiation and antibody-based therapies. Technical innovations are needed to overcome field inhomogeneity and susceptibility artifacts in certain regions of the skull. Finally, larger studies comparing 1.5 T, 3.0 T, and 7.0 T or greater will determine whether UHF MRI gains acceptance as a clinical standard.


Subject(s)
Brain Neoplasms/pathology , Brain Neoplasms/therapy , Magnetic Resonance Imaging , Humans
7.
MAGMA ; 29(1): 49-58, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26646522

ABSTRACT

OBJECTIVE: To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). MATERIALS AND METHODS: In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. RESULTS: ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). CONCLUSION: Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.


Subject(s)
Carcinoma, Hepatocellular/diagnostic imaging , Liver Neoplasms/diagnostic imaging , Liver/pathology , Magnetic Resonance Imaging/methods , Aged , Algorithms , Arteries/diagnostic imaging , Arteries/pathology , Humans , Image Processing, Computer-Assisted , Liver/diagnostic imaging , Male , Perfusion , Prospective Studies , Reproducibility of Results , Water/chemistry
8.
AJR Am J Roentgenol ; 204(3): 510-8, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25714279

ABSTRACT

OBJECTIVE. The objective of our study was to evaluate the performance of a high-spatial-resolution 2D phase-contrast (PC) MRI technique accelerated with compressed sensing for portal vein (PV) and hepatic artery (HA) flow quantification in comparison with a standard PC MRI sequence. SUBJECTS AND METHODS. In this prospective study, two PC MRI sequences were compared, one with parallel imaging acceleration and low spatial resolution (generalized autocalibrating partial parallel acquisition [GRAPPA]) and one with compressed sensing acceleration and high spatial resolution (sparse). Seventy-six patients were assessed, including 37 patients with cirrhosis. Two observers evaluated PC image quality. Quantitative analyses yielded a mean velocity, flow, and vessel area for the PV and HA and an arterial fraction. The PC techniques were compared using the paired Wilcoxon test and Bland-Altman statistics. The sensitivity of the flow parameters to the severity of cirrhosis was also assessed. RESULTS. Vessel delineation was significantly improved using the PC sparse sequence (p < 0.034). For both in vitro and in vivo measurements, PC sparse yielded lower estimates for vessel area and flow, and larger differences between PC GRAPPA and PC sparse were observed in the HA. PV velocity and flow were significantly lower in patients with cirrhosis on both PC sparse (p < 0.001 and p = 0.042, respectively) and PC GRAPPA (p < 0.001 and p = 0.005, respectively). PV velocity correlated negatively with Child-Pugh class (r = -0.50, p < 0.001), whereas the arterial fraction measured with PC sparse was higher in patients with Child-Pugh class B or C disease than in those with Child-Pugh class A disease, with a trend toward significance (p = 0.055). CONCLUSION. A high-spatial-resolution highly accelerated compressed sensing technique (PC sparse) allows total hepatic blood flow measurements obtained in 1 breath-hold, provides improved delineation of the hepatic vessels compared with a standard PC MRI sequence (GRAPPA), and can potentially be used for the noninvasive assessment of liver cirrhosis.


Subject(s)
Hepatic Artery/physiology , Liver Cirrhosis/physiopathology , Magnetic Resonance Imaging/methods , Portal Vein/physiology , Regional Blood Flow , Female , Humans , Male , Middle Aged , Prospective Studies
9.
AJR Am J Roentgenol ; 204(1): 59-68, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25539238

ABSTRACT

OBJECTIVE: The objective of our study was to compare diffusion-weighted imaging (DWI) sequences using a bipolar versus a monopolar single-shot echo-planar imaging (EPI) gradient design for image quality and for lesion detection and characterization in patients with liver disease. MATERIALS AND METHODS: In this retrospective study, 77 patients with chronic liver disease who underwent MRI including bipolar and monopolar DWI at 1.5 T were assessed. Two independent observers reviewed the DWI studies for image quality and the detection and characterization of liver lesions. The reference standard for diagnosis was established by consensus review of two different observers using imaging characteristics on conventional MRI sequences, lesion stability over time, pathologic correlation, or a combination of these findings. The estimated signal-to-noise ratio (SNR) of liver parenchyma and apparent diffusion coefficients (ADCs) of the liver and lesions were calculated for both sequences. ROC analysis was conducted to evaluate the performance of ADC for the diagnosis of hepatocellular carcinoma (HCC). RESULTS: Eighty-five lesions, 50 HCCs and 35 benign lesions, were detected with the reference standard in 38 patients. There was equivalent image quality for the bipolar and monopolar sequences (p = 0.24-0.42). The HCC detection rate for observers 1 and 2 was slightly better with bipolar DWI (50.0% and 52.0%, respectively) compared with monopolar DWI (44.0% and 46.0%); however, this difference did not reach statistical significance. The estimated SNR was higher with the monopolar sequence than with the bipolar sequence (p ≤ 0.001). The AUC for the ROC curve was 0.691 for bipolar DWI and 0.649 for monopolar DWI when ADC was used for the characterization of HCC, which is not a statistically significant difference (p = 0.59). CONCLUSION: The higher estimated SNR yielded by the monopolar DWI sequence did not translate into better HCC detection compared with the bipolar DWI sequence. ADC has a limited role for HCC characterization in patients with liver disease.


Subject(s)
Algorithms , Carcinoma, Hepatocellular/pathology , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Liver Cirrhosis/pathology , Liver Neoplasms/pathology , Adult , Carcinoma, Hepatocellular/etiology , Chronic Disease , Diagnosis, Differential , Female , Humans , Liver Cirrhosis/complications , Liver Neoplasms/etiology , Male , Middle Aged , Observer Variation , Reproducibility of Results , Sensitivity and Specificity
10.
Abdom Imaging ; 40(4): 803-9, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25294006

ABSTRACT

PURPOSE: To compare MR elastography (MRE) using a single and a dual driver excitation for the quantification of hepatic and splenic stiffness (HS and SS), and to investigate the performance of HS and SS measured with single or dual driver excitation for the detection of liver cirrhosis in subjects with liver disease. PATIENTS AND METHODS: This prospective HIPAA compliant and IRB approved study involved 49 subjects who underwent MRE at 3.0T, comparing three different acquisition methods (single driver on the liver, single driver on the spleen and dual driver acoustic excitation). A Mann-Whitney test was used to assess changes in stiffness values. Bland-Altman analysis was used to compare single and dual driver configurations for each organ. Performance for detection of liver cirrhosis was assessed using ROC analysis. Pearson correlation was used to estimate the dependence of HS and SS on spleen size. RESULTS: There were 40 noncirrhotic and 9 cirrhotic patients. There was good agreement between stiffness values measured with a single or a dual driver (Bland-Altman limits of agreement -14.3 % to 18.9 % and -18.1 % to 29.7 %, CV 6.4 % and 9.4 %, for HS and SS. respectively). HS and SS were higher in subjects with liver cirrhosis (p < 0.001), with excellent detection performance (AUROC range 0.87-0.93). SS correlated strongly with spleen size (r = 0.69, p < 0.001), while HS showed weak correlation (r = 0.38, p = 0.006). CONCLUSION: Using a dual acoustic driver configuration, hepatic and splenic stiffness can be simultaneously estimated with good concordance with single driver measurement.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Cirrhosis/pathology , Liver/pathology , Magnetic Resonance Imaging/methods , Spleen/pathology , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results , Young Adult
11.
PLoS One ; 9(12): e115667, 2014.
Article in English | MEDLINE | ID: mdl-25546176

ABSTRACT

PURPOSE: To assess the quality of the arterial input function (AIF) reconstructed using a dedicated pre-bolus low-dose contrast material injection imaged with a high temporal resolution and the resulting estimated liver perfusion parameters. MATERIALS AND METHODS: In this IRB-approved prospective study, 24 DCE-MRI examinations were performed in 21 patients with liver disease (M/F 17/4, mean age 56 y). The examination consisted of 1.3 mL and 0.05 mmol/kg of gadobenate dimeglumine for pre-bolus and main bolus acquisitions, respectively. The concentration-curve of the abdominal aorta in the pre-bolus acquisition was used to reconstruct the AIF. AIF quality and shape parameters obtained with pre-bolus and main bolus acquisitions and the resulting estimated hepatic perfusion parameters obtained with a dual-input single compartment model were compared between the 2 methods. Test-retest reproducibility of perfusion parameters were assessed in three patients. RESULTS: The quality of the pre-bolus AIF curve was significantly better than that of main bolus AIF. Shape parameters peak concentration, area under the time activity curve of gadolinium contrast at 60 s and upslope of pre-bolus AIF were all significantly higher, while full width at half maximum was significantly lower than shape parameters of main bolus AIF. Improved liver perfusion parameter reproducibility was observed using pre-bolus acquisition [coefficient of variation (CV) of 4.2%-38.7% for pre-bolus vs. 12.1-71.4% for main bolus] with the exception of distribution volume (CV of 23.6% for pre-bolus vs. 15.8% for main bolus). The CVs between pre-bolus and main bolus for the perfusion parameters were lower than 14%. CONCLUSION: The AIF reconstructed with pre-bolus low dose contrast injection displays better quality and shape parameters and enables improved liver perfusion parameter reproducibility, although the resulting liver perfusion parameters demonstrated no clinically significant differences between pre-bolus and main bolus acquisitions.


Subject(s)
Contrast Media/administration & dosage , Hepatitis/diagnosis , Liver/physiology , Magnetic Resonance Imaging/methods , Meglumine/analogs & derivatives , Organometallic Compounds/administration & dosage , Adult , Aged , Female , Humans , Liver/blood supply , Male , Meglumine/administration & dosage , Middle Aged
12.
Transl Oncol ; 7(1): 153-66, 2014 Feb.
Article in English | MEDLINE | ID: mdl-24772219

ABSTRACT

Pharmacokinetic analysis of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) time-course data allows estimation of quantitative parameters such as K (trans) (rate constant for plasma/interstitium contrast agent transfer), v e (extravascular extracellular volume fraction), and v p (plasma volume fraction). A plethora of factors in DCE-MRI data acquisition and analysis can affect accuracy and precision of these parameters and, consequently, the utility of quantitative DCE-MRI for assessing therapy response. In this multicenter data analysis challenge, DCE-MRI data acquired at one center from 10 patients with breast cancer before and after the first cycle of neoadjuvant chemotherapy were shared and processed with 12 software tools based on the Tofts model (TM), extended TM, and Shutter-Speed model. Inputs of tumor region of interest definition, pre-contrast T1, and arterial input function were controlled to focus on the variations in parameter value and response prediction capability caused by differences in models and associated algorithms. Considerable parameter variations were observed with the within-subject coefficient of variation (wCV) values for K (trans) and v p being as high as 0.59 and 0.82, respectively. Parameter agreement improved when only algorithms based on the same model were compared, e.g., the K (trans) intraclass correlation coefficient increased to as high as 0.84. Agreement in parameter percentage change was much better than that in absolute parameter value, e.g., the pairwise concordance correlation coefficient improved from 0.047 (for K (trans)) to 0.92 (for K (trans) percentage change) in comparing two TM algorithms. Nearly all algorithms provided good to excellent (univariate logistic regression c-statistic value ranging from 0.8 to 1.0) early prediction of therapy response using the metrics of mean tumor K (trans) and k ep (=K (trans)/v e, intravasation rate constant) after the first therapy cycle and the corresponding percentage changes. The results suggest that the interalgorithm parameter variations are largely systematic, which are not likely to significantly affect the utility of DCE-MRI for assessment of therapy response.

13.
Radiology ; 266(3): 920-9, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23220895

ABSTRACT

PURPOSE: To optimize intravoxel incoherent motion (IVIM) diffusion-weighted (DW) imaging by estimating the effects of diffusion gradient polarity and breathing acquisition scheme on image quality, signal-to-noise ratio (SNR), IVIM parameters, and parameter reproducibility, as well as to investigate the potential of IVIM in the detection of hepatic fibrosis. MATERIALS AND METHODS: In this institutional review board-approved prospective study, 20 subjects (seven healthy volunteers, 13 patients with hepatitis C virus infection; 14 men, six women; mean age, 46 years) underwent IVIM DW imaging with four sequences: (a) respiratory-triggered (RT) bipolar (BP) sequence, (b) RT monopolar (MP) sequence, (c) free-breathing (FB) BP sequence, and (d) FB MP sequence. Image quality scores were assessed for all sequences. A biexponential analysis with the Bayesian method yielded true diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF) in liver parenchyma. Mixed-model analysis of variance was used to compare image quality, SNR, IVIM parameters, and interexamination variability between the four sequences, as well as the ability to differentiate areas of liver fibrosis from normal liver tissue. RESULTS: Image quality with RT sequences was superior to that with FB acquisitions (P = .02) and was not affected by gradient polarity. SNR did not vary significantly between sequences. IVIM parameter reproducibility was moderate to excellent for PF and D, while it was less reproducible for D*. PF and D were both significantly lower in patients with hepatitis C virus than in healthy volunteers with the RT BP sequence (PF = 13.5% ± 5.3 [standard deviation] vs 9.2% ± 2.5, P = .038; D = [1.16 ± 0.07] × 10(-3) mm(2)/sec vs [1.03 ± 0.1] × 10(-3) mm(2)/sec, P = .006). CONCLUSION: The RT BP DW imaging sequence had the best results in terms of image quality, reproducibility, and ability to discriminate between healthy and fibrotic liver with biexponential fitting.


Subject(s)
Artifacts , Diffusion Magnetic Resonance Imaging/methods , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Liver Cirrhosis/pathology , Respiratory Mechanics , Respiratory-Gated Imaging Techniques/methods , Adult , Aged , Algorithms , Female , Humans , Male , Middle Aged , Motion , Reproducibility of Results , Sensitivity and Specificity , Young Adult
14.
Magn Reson Med ; 67(4): 1054-64, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22083998

ABSTRACT

Phase-contrast (PC) cine MRI is a promising method for assessment of pathologic hemodynamics, including cardiovascular and hepatoportal vascular dynamics, but its low data acquisition efficiency limits the achievable spatial and temporal resolutions within clinically acceptable breath-hold durations. We propose to accelerate PC cine MRI using an approach which combines compressed sensing and parallel imaging (k-t SPARSE-SENSE). We validated the proposed 6-fold accelerated PC cine MRI against 3-fold accelerated PC cine MRI with parallel imaging (generalized autocalibrating partially parallel acquisitions). With the programmable flow pump, we simulated a time varying waveform emulating hepatic blood flow. Normalized root mean square error between two sets of velocity measurements was 2.59%. In multiple blood vessels of 12 control subjects, two sets of mean velocity measurements were in good agreement (mean difference = -0.29 cm/s; lower and upper 95% limits of agreement = -5.26 and 4.67 cm/s, respectively). The mean phase noise, defined as the standard deviation of the phase in a homogeneous stationary region, was significantly lower for k-t SPARSE-SENSE than for generalized autocalibrating partially parallel acquisitions (0.05 ± 0.01 vs. 0.19 ± 0.06 radians, respectively; P < 0.01). The proposed 6-fold accelerated PC cine MRI pulse sequence with k-t SPARSE-SENSE is a promising investigational method for rapid velocity measurement with relatively high spatial (1.7 mm × 1.7 mm) and temporal (∼35 ms) resolutions.


Subject(s)
Liver/blood supply , Magnetic Resonance Imaging, Cine/methods , Adult , Algorithms , Blood Flow Velocity , Cardiac-Gated Imaging Techniques , Computer Simulation , Female , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/instrumentation , Male , Phantoms, Imaging