Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 43
Filter
2.
J Endovasc Ther ; : 15266028231180350, 2023 Jun 13.
Article in English | MEDLINE | ID: mdl-37309126

ABSTRACT

PURPOSE: The covered endovascular reconstruction of the aortic bifurcation (CERAB) technique offers an alternative for Trans-Atlantic Inter-Society Consensus (TASC) C/D lesions involving the aortic bifurcation. The study aims to evaluate the outcomes of the CERAB technique for extensive aortoiliac occlusive disease (AIOD) using the BeGraft balloon-expandable covered stent (BECS). MATERIALS AND METHODS: This is a physician-initiated, multicenter, retrospective, observational study. Between June 2017 and June 2021, all consecutive patients who underwent the CERAB procedure using the BeGraft stent (Bentley InnoMed, Hechingen, Germany) in 3 clinics were enrolled. Patients' demographics, lesion characteristics, and procedural results were collected and retrospectively analyzed. Follow-up was done at 1, 6, and 12 months and then annually with clinical examination, ankle-brachial index (ABI), and duplex ultrasound. The primary endpoint was the patency at 12 months. Secondary endpoints included procedural-related complications, secondary patency, freedom from target lesion revascularization (TLR), and clinical improvement. RESULTS: In all, 120 patients (64 men) with a median age of 65 years (range: 34-84 years) were analyzed. Most patients had extensive AIOD classified as TASC II C (n=32; 26.7%) or TASC II D (n=81; 67.5%). The median duration of the procedure was 120 minutes (interquartile range [IQR]: 80-180 minutes). All 454 BeGraft stents (137 aortic and 317 peripheral) were successfully delivered and deployed. The overall procedural complication rate was 14 (11.7%). The median hospital length of stay was 5 days (IQR: 3-6 days). All patients improved clinically, and the ABI increased significantly (p<0.05). The median follow-up was 19 months (range: 6-56 months). The primary patency rate, secondary patency rate, and freedom from TLR at 12 months were 94.5%, 97.3%, and 93.5%, respectively. CONCLUSIONS: The CERAB procedure with BeGraft BECSs has a high technical success rate, favorable patency outcomes, and low morbidity, even in relatively ill patients with extensive AIOD. Prospective randomized studies on the CERAB technique are definitely recommended. CLINICAL IMPACT: This study evaluates the outcomes of BeGraft stents used during the covered endovascular reconstruction of the aortic bifurcation (CERAB) procedure. To date, several balloon-expandable covered stents have been used for this technique with satisfactory results. This study showed the safety and excellent patency of the CERAB technique in extensive AIOD using BeGraft balloon-expandable covered stents.

3.
Pol Przegl Chir ; 95(4): 1-5, 2022 Apr 07.
Article in English | MEDLINE | ID: mdl-36807090

ABSTRACT

INTRODUCTION: To investigate the influence of iliac vein stenosis on clinical course and recurrence of primary varicose veins after surgeryMaterials and methods: Thirty-three patients with primary varicose veins qualified for great saphenous vein stripping were analysed. The stenosis of common (CIV) and external (EIV) iliac vein was measured by IVUS and defined in three categories as minimal lumen area <90 mm2 for CIV and <75 mm2 for EIV, minimal lumen diameter <10 mm for CIV and <7.5 mm for EIV and area reduction >50%. The patients were assessed clinically and by Duplex ultrasound 48 to 72 months after the procedure. Any recurrence, the recurrence in the saphenofemoral junction (SFJ), change in Venous Clinical Severity Score ( VCSS), were analyzed in relation to the stenosis in the CIV and EIV. RESULTS: The follow-up was completed in 27 patients. Any recurrence and the recurrence in the SFJ were observed in 70% and 18.5% of patients, respectively. There were no statistically significant differences in any recurrence, the recurrence in the SFJ and VCSS in relation to CIV and EIV stenosis in any category. CONCLUSIONS: Iliac vein stenosis does not influence the clinical course and recurrence of primary varicose veins after surgery.


Subject(s)
Iliac Vein , Varicose Veins , Humans , Constriction, Pathologic , Recurrence , Varicose Veins/surgery , Disease Progression , Treatment Outcome
4.
Pol Przegl Chir ; 93(5): 1-5, 2021 Jun 23.
Article in English | MEDLINE | ID: mdl-34552026

ABSTRACT

Objectives The diagnosis of deep venous thrombosis (DVT) is hampered in patients with primary varicose veins due to similarity of symptoms of DVT and PVV and elevated levels of D-dimers. The purpose of this study was to analyze factors that influence the D-dimer concentration in patients with PVV in order to redefine its diagnostic value. Methods Forty- one patients with non-complicated PVV were enrolled in the study, in whom D-dimer level was determined by immunoturbidimetric assay. The influence of selected clinical factors on the concentration of D-dimers was determined with univariate and bivariate analysis. Besides descriptive statistics the D-dimers levels were compared to the age -adjusted cutoff values. Results The median concentration of D-dimer was 630.0 ng/ml (440.0-1140.0 ng/ml) and was above the age-adjusted level in 21 (52%) of patients. There was a positive correlation between the patient's age and and D-dimer concentration (p = 0.035, Spearman correlation coefficient rs=0,33. The bivariate analysis showed a significant interaction between age and weight p=0,02. Conclusions In patients with PVV the diagnostic value of D-dimers is limited especially in older and overweight subjects.


Subject(s)
Varicose Veins , Venous Thrombosis , Aged , Fibrin Fibrinogen Degradation Products , Humans , Predictive Value of Tests , Varicose Veins/diagnosis , Venous Thrombosis/diagnosis
5.
Postepy Kardiol Interwencyjnej ; 17(1): 93-100, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33868423

ABSTRACT

INTRODUCTION: Currently, there is a wide range of commercially available devices for endovascular aneurysm repair (EVAR) that differ in terms of both anatomical requirements and the technology and technique of deployment. AIM: To assess the applicability of currently commercially available devices for EVAR in the treatment of an asymptomatic abdominal aneurysm (AAA). MATERIAL AND METHODS: The study group included 100 patients with infrarenal AAA with a maximum diameter ≥ 50 mm, qualified for invasive treatment at the University Hospital in 2013-2014. The aortoiliac morphological characteristics of the AAA were evaluated on preoperative computed tomography angiograms using the OsiriX DICOM viewer in the 3D-MPR mode. The morphological applicability of 14 types of CE-marked and FDA-approved stent grafts was determined based on their instructions for use (IFU). RESULTS: EVAR was feasible with at least one of the analysed devices in 68% of patients. The morphological applicability was as follows: Excluder Conformable (65%), Ovation iX (51%), Endurant II (47%), Treo (45%), Excluder C3 (45%), AFX 2 (45%), Incraft (44%), E-tegra (44%), Zenith Alfa (41%), Zenith Flex (40%), Anaconda (39%) Aorfix (37%), Altura (34%), and E-vita (20%). The differences in the stent graft applicability were statistically significant (p < 0.001). A wide diameter of the common iliac artery, angulated proximal neck, and diameter of proximal neck out of range constituted the most frequent causes of EVAR inapplicability. CONCLUSIONS: The IFU-based applicability of currently available AAA stent graft systems differs significantly. Despite the constant evolution of EVAR technology, at least 32% of AAA will require a different therapeutic approach.

6.
Vasc Endovascular Surg ; 55(1): 39-49, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33034263

ABSTRACT

PURPOSE: To report mid-term results of endovascular aneurysm sealing (EVAS) of abdominal aortic aneurysms (AAA) deemed unsuitable for a standard endovascular aneurysm repair (EVAR). METHODS: A prospectively maintained database of 42 patients with EVAR-unfavorable anatomy treated by EVAS combined with chimney grafts in case of the proximal AAA neck shorter than 5 mm was analyzed. Early outcomes included final angiographic result, intra- and early post-operative deaths, and complications. Mid-term outcomes included all-cause mortality (ACM), aneurysm-related mortality (ARM), patency of the stents, occurrence of endoleaks, serious complications and graft failures defined as the AAA growth of more than 5 mm, type I endoleak, occlusion of the stent-graft or chimney graft, aorto-duodenal fistula, or aneurysm rupture. RESULTS: The procedure was completed in all patients. Twenty-eight chimney grafts were implanted in 19 patients. Patients were followed for a median of 24 months (range 12-34 months). There were 2 intraoperative ruptures and 1 patient died in an early postoperative period. The cumulative ACM was 15, 21, and 36% at 12, 24, and 36 months, respectively, and the cumulative ARM was 8, 11, and 27% at 12, 24, and 36 months, respectively. Three out of 5 aneurysm-related deaths were due to a secondary aorto-duodenal fistula. The cumulative incidence of graft failure was 20, 27, and 42% at 12, 24, and 36 months, respectively. The cumulative incidence of an endoleak was 5, 9, and 23% at 12, 24, and 36 months, respectively. The graft failure increased significantly both ACM (p = .012) and ARM (p = .00003). The implantation of chimney grafts at the initial procedure increased ARM significantly (p = .008). The presence of an endoleak did not have any significant influence on ACM and ARM. CONCLUSION: Patients treated with EVAS for AAAs with EVAR-unfavorable anatomy, especially those with chimney grafts, exhibit a high risk of graft failure and subsequent death.


Subject(s)
Aortic Aneurysm, Abdominal/therapy , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Databases, Factual , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Postoperative Complications/mortality , Postoperative Complications/therapy , Prosthesis Failure , Risk Assessment , Risk Factors , Stents , Time Factors , Treatment Outcome , Vascular Patency
8.
Ann Vasc Surg ; 69: 382-390, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32504793

ABSTRACT

BACKGROUND: The purpose of the study was to evaluate the feasibility and efficacy of the novel BeGraft covered stent for the treatment of abdominal penetrating aortic ulcer (PAU) or penetrating ulcers of the iliac arteries (PUIAs). METHODS: This was a single-center observational study, which included 24 consecutive patients who underwent endovascular surgery due to abdominal PAU or PUIA between June 2017 and September 2019. Demographics of patients, lesion characteristics, diameter and length of the BeGraft stents, and postoperative events were prospectively collected and retrospectively analyzed. Follow-up examinations were performed at 1, 6, 12, and 24 months with clinical and hemodynamic evaluation. Outcome measures included technical success, perioperative complications, and stent patency. RESULTS: A total of 24 patients (13 men and 11 women), with a median age of 67 years (range, 42-81 years), were analyzed. Among them, 20 patients were symptomatic, and 4 patients underwent elective surgery because of the size of PAU. A total of 54 BeGraft stents (26 aortic and 28 peripheral) were successfully delivered and deployed to cover 13 aortic and 13 common iliac artery ulcer lesions. The technical success rate was 100%. The average procedural time was 53.8 ± 12.8 min. Complications included one case of the access-site pseudoaneurysm, which was successfully treated by thrombin injection. During a median follow-up of 20.5 months (range, 6-33 months), all stents remained patent, without endoleak or ulcer recurrence. CONCLUSIONS: BeGraft stents used during endovascular treatment of abdominal PAU and PUIA lesions are associated with favorable outcomes regarding technical success and patency. The primary use of BeGraft covered stents provides a valid option for patients with abdominal PAU. Long-term follow-up is required to confirm these promising results.


Subject(s)
Angioplasty, Balloon/instrumentation , Aorta, Abdominal , Aortic Diseases/therapy , Iliac Artery , Stents , Ulcer/therapy , Adult , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Aorta, Abdominal/diagnostic imaging , Aortic Diseases/diagnostic imaging , Feasibility Studies , Female , Humans , Iliac Artery/diagnostic imaging , Male , Middle Aged , Poland , Retrospective Studies , Time Factors , Treatment Outcome , Ulcer/diagnostic imaging
9.
Ultrasound Med Biol ; 46(7): 1707-1714, 2020 07.
Article in English | MEDLINE | ID: mdl-32402670

ABSTRACT

The aim of the study was to evaluate the effectiveness of Angio PLanewave UltraSensitive imaging (Angio PL.U.S.) as an alternative to contrast-enhanced ultrasound (CEUS) and computed tomography angiography (CTA) for endoleak detection and classification in patients after endovascular aneurysm repair. A total of 28 patients underwent a post-endovascular aneurysm repair follow-up with color Doppler ultrasound, power Doppler ultrasound, CEUS, Angio PL.U.S and CTA examinations. CTA revealed 17 endoleaks in 14 patients (50%): 3 type Ia, 13 type II and 1 type III. There were no differences between Angio PL.U.S. and CEUS in terms of sensitivity, specificity or accuracy (93%, 100% and 97%). We did not observe any statistically significant differences between CTA, CEUS and Angio PL.U.S. in terms of the endoleak identification ability. Angio PL.U.S. may be considered as a potential tool to follow-up patients after endovascular aneurysm repair implantation, especially in patients who cannot be examined with CTA or CEUS.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Endoleak/diagnostic imaging , Endovascular Procedures/methods , Ultrasonography, Doppler/methods , Aged , Endoleak/diagnosis , Endovascular Procedures/adverse effects , Female , Humans , Male , Prospective Studies
10.
Phlebology ; 35(5): 354-360, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31645193

ABSTRACT

OBJECTIVES: The purpose of this study is to report the intravascular ultrasound morphometry of iliac veins and its relation to demographic and anthropometric factors in subjects without chronic venous insufficiency. METHODS: Thirty-three patients, without chronic venous insufficiency - qualified to great saphenous vein stripping due to unilateral, primary varicose veins - participated in the study. During the surgery, left and right external iliac veins, common iliac veins and inferior vena cava were interrogated with intravascular ultrasound. The morphometric analysis included measurement of a cross-sectional area at normal, non-stenosed vein segments (ref-CSA) and at the point of the most prominent narrowing (minimal lumen area (MLA)). Based on these measurements, a percentage of stenosis (S%) and calculated lumen diameter of interrogated veins were determined according to the following formulas, S% = (ref-CSA-MLA)/ref-CSA × 100 and CLD = 2 × âˆš(ref-CSA/π), respectively. RESULTS: Median ref-CSA, S% and calculated lumen diameter were 265.3 mm2, 45.8% and 18.4 mm for inferior vena cava; 193.9 mm2, 62.4% and 15.7 mm for left common iliac veins; 166.9 mm2, 35.7% and 14.2 mm for right common iliac veins; 136.5 mm2, 48.0% and 12.8 mm for left external iliac veins and 140.9 mm2, 46.3% and 13.5 mm for right external iliac veins. There were statistically significant differences between left and right common iliac veins ref-CSA, common iliac veins S% and common iliac veins calculated lumen diameter (p = 0.03, p < 0 and p = 0.03, respectively). The S% of left external iliac veins was greater in women 52.2 versus 37.2% in men (p = 0.04). Neither age nor anthropometric factors had any influence on the calculated lumen diameter of the analysed veins. A negative correlation between the left common iliac veins S% and the age was observed (p = 0.03). CONCLUSIONS: In adult subjects, the calculated lumen diameter of the common iliac veins is greater on the left side and is not influenced by age and body size. Common iliac vein stenosis occurs more frequently on the left side, decreases with age and tends to be more frequent in women.


Subject(s)
Iliac Vein/diagnostic imaging , Peripheral Vascular Diseases/diagnostic imaging , Saphenous Vein/surgery , Ultrasonography, Interventional , Varicose Veins/surgery , Vascular Surgical Procedures , Vena Cava, Inferior/diagnostic imaging , Adult , Aged , Clinical Decision-Making , Constriction, Pathologic , Endovascular Procedures/instrumentation , Female , Humans , Ligation , Male , Middle Aged , Peripheral Vascular Diseases/therapy , Predictive Value of Tests , Saphenous Vein/diagnostic imaging , Stents , Varicose Veins/diagnostic imaging , Young Adult
11.
Abdom Radiol (NY) ; 43(12): 3479-3486, 2018 12.
Article in English | MEDLINE | ID: mdl-29876784

ABSTRACT

PURPOSE: The aim of the study was to assess the effectiveness of Superb Micro-vascular Imaging (SMI) as an alternative to Contrast-Enhanced Ultrasound (CEUS) and Computed Tomography Angiography (CTA) for endoleak detection and classification in patients followed up after endovascular abdominal aortic aneurysm repair (EVAR). MATERIALS AND METHODS: From May 2015 to January 2017, 30 patients underwent post-EVAR follow-up with Color Doppler Ultrasound (CDUS), CEUS, SMI, and CTA examinations. Aneurysmal sac diameter and graft patency were evaluated; endoleaks were identified and classified. Sensitivity, specificity, and accuracy values were calculated for each of the four diagnostic methods of endoleak detection. A percentage of agreement and Cohen's Kappa coefficient were calculated for comparison of methods in terms of endoleak identification. RESULTS: CTA revealed fifteen endoleaks (50%): three type Ia, nine type II, and three type III. The sensitivity of CDUS, CEUS, and SMI relative to CTA was 27%, 100%, and 100%, respectively. Specificity was 93%, 93%, and 93%, respectively. Accuracy was 60%, 97%, and 97%, respectively. There were no differences between SMI and CEUS in terms of sensitivity, specificity, or accuracy (100%, 93%, and 97%). We do not observe statistically significant differences between CTA, CEUS, and SMI concerning endoleak identification ability. The weakest method in endoleak identification was CDUS. CONCLUSIONS: The analysis showed that SMI is effective, repeatable, and comparable with the CEUS modality in identification endoleaks after EVAR; it may be considered as a potential tool to monitor patients after EVAR implantation, especially those with renal insufficiency or with an allergy to any contrast media.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/therapy , Endoleak/diagnostic imaging , Endovascular Procedures , Microvessels/diagnostic imaging , Ultrasonography, Doppler, Color/methods , Aged , Aorta, Abdominal/diagnostic imaging , Female , Follow-Up Studies , Humans , Male , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity , Treatment Outcome
12.
Ann Vasc Surg ; 52: 49-56, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29772324

ABSTRACT

BACKGROUND: Morphology is one of the most important factors influencing the long-term durability of endovascular repair of an infrarenal abdominal aortic aneurysm (AAA). The knowledge of morphological characteristics of AAA that may differ in various populations seems to be important for further development of a technology of endovascular repair as well as for planning of treatment strategies. To analyze the current applicability of endovascular aneurysm repair (EVAR) in patients with an infrarenal AAA with an indication for elective treatment in west-central Poland. METHODS: Computed tomography angiograms of 100 consecutive patients with infrarenal AAA deemed to require treatment were analyzed with an OsiriX DICOM viewer in 3D-multiplanar reconstruction mode. Proximal neck diameter, length, angulation, shape, the presence of thrombus and calcification, distal neck diameter, and morphology of the iliac arteries were determined. Three sets of morphological criteria were established. The optimal criteria consisted of a nonconical proximal neck without moderate or severe calcification or thrombus, with a diameter of 18-28 mm, length of ≥15 mm, and ß angulation of <60%; a distal neck with a diameter of ≥20 mm; a landing zone in the common iliac arteries (CIAs) with a length of ≥10 mm and diameter of ≤20 mm; and external iliac arteries with diameters of ≥7 mm. The suboptimal criteria included proximal neck diameters of 18-32 mm, neck lengths ≥10 mm, infrarenal neck angulations of up to 75°, and CIA diameters of up to 25 mm. Finally, the extended suboptimal criteria included proximal neck diameters of 16-34 mm and infrarenal neck angulations ≤90°, without limits in the maximal diameter of the CIAs. RESULTS: The median maximum aneurysm diameter was 61 mm. The optimal, suboptimal, and extended suboptimal criteria were met by 23%, 32%, and 53% of patients, respectively. The most common deviations were wide, conical, and angulated proximal necks and aneurysmal iliac arteries. CONCLUSIONS: The majority of patients with AAA deemed to be candidates for elective repair do not meet the most favorable criteria for EVAR. Availability of better endovascular solutions for conical, angulated, and wide necks and aneurysmal iliac arteries would likely expand EVAR applicability. Open repair remains a valid option.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Iliac Aneurysm/surgery , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/epidemiology , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Clinical Decision-Making , Computed Tomography Angiography , Elective Surgical Procedures , Endovascular Procedures/adverse effects , Feasibility Studies , Female , Humans , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/epidemiology , Male , Middle Aged , Patient Selection , Poland/epidemiology , Predictive Value of Tests , Retrospective Studies , Risk Factors , Treatment Outcome
13.
J Vasc Surg ; 67(4): 1102-1109, 2018 04.
Article in English | MEDLINE | ID: mdl-29074113

ABSTRACT

OBJECTIVE: To describe the factors associated with survival 20 years after endovascular treatment of an abdominal aortic aneurysm (AAA) in a single center. METHODS: Prospective cohort of asymptomatic patients with an infrarenal aortic aneurysm treated with a bifurcated endovascular graft (Talent) between June 1997 and August 2008. Cox proportional hazard multivariable regression was used for analysis of independent risk factors for survival. Kaplan-Meier curves were done with the long-rank test. P < .05 was considered significant. RESULTS: We followed 229 patients, 184 without an endoleak and 45 with an endoleak. Ages ranged between 52 and 89 years, and the mean diameter of the aneurysm was 59.51 ± 14.6 mm. Implantation of the endovascular graft was possible in 99% of the patients. The 30-day mortality rate was 3.4%. In the Cox regression, age <73 years (hazard ratio [HR], 0.42; 95% confidence interval [CI], 0.27-0.64), aneurysm size ≤55 mm (HR, 0.62; 95% CI, 0.40-0.95), male sex (HR, 0.17; 95% CI, 0.05-0.52), American Society of Anesthesiologists surgical risk category I and II vs III and IV (HR, 0.51; 95% CI, 0.34-0.75), and aneurysm size reduction ≤3 mm after treatment (HR, 2.23; 95% CI, 1.11-4.51) were significantly correlated with the survival of the patients followed in this long-term case series. CONCLUSIONS: This 20-year prospective cohort included patients with an AAA treated with a bifurcated endovascular graft (Talent) at a university hospital in Brazil. This study supports that sex, age, aneurysm size, aneurysm size reduction, and American Society of Anesthesiologists surgical risk category are significantly correlated with patient survival after endovascular treatment of the AAA.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Age Factors , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Brazil , Cause of Death , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Hospitals, University , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Multivariate Analysis , Proportional Hazards Models , Prosthesis Design , Retrospective Studies , Risk Factors , Sex Factors , Time Factors , Treatment Outcome
14.
J Vasc Surg Venous Lymphat Disord ; 5(5): 678-687, 2017 09.
Article in English | MEDLINE | ID: mdl-28818221

ABSTRACT

OBJECTIVE: The Venogram vs IVUS for Diagnosing Iliac vein Obstruction (VIDIO) trial was designed to compare the diagnostic efficacy of intravascular ultrasound (IVUS) with multiplanar venography for iliofemoral vein obstruction. METHODS: During a 14-month period beginning July 2014, 100 patients with chronic Clinical, Etiologic, Anatomic, and Pathophysiologic clinical class C4 to C6 venous disease and suspected iliofemoral vein obstruction were enrolled at 11 U.S. and 3 European sites. The inferior vena cava and common iliac, external iliac, and common femoral veins were imaged. Venograms were measured for vein diameter; IVUS provided diameter and area measurements. Multiplanar venograms included three views: anteroposterior and 30-degree right and left anterior oblique views. A core laboratory evaluated the deidentified images, determining stenosis severity as the ratio between minimum luminal diameter and reference vessel diameter, minimal luminal area, and reference vessel area. A 50% diameter stenosis by venography and a 50% cross-sectional area reduction by IVUS were considered significant. Analyses assessed change in procedures performed on the basis of imaging method and concordance of measurements between each imaging method. RESULTS: Venography identified stenotic lesions in 51 of 100 subjects, whereas IVUS identified lesions in 81 of 100 subjects. Compared with IVUS, the diameter reduction was on average 11% less for venography (P < .001). The intraclass correlation coefficient was 0.505 for vein diameter stenosis calculated with the two methods. IVUS identified significant lesions not detected with three-view venography in 26.3% of patients. Investigators revised the treatment plan in 57 of 100 cases after IVUS, most often because of failure of venography to detect a significant lesion (41/57 [72%]). IVUS led to an increased number of stents in 13 of 57 subjects (23%) and the avoidance of an endovascular procedure in 3 of 57 subjects (5%). Overall, IVUS imaging changed the treatment plan in 57 patients; 54 patients had stents placed on the basis of IVUS detection of significant iliofemoral vein obstructive lesions not appreciated with venography, whereas 3 patients with significant lesions on venography had no stent placed on the basis of IVUS. CONCLUSIONS: IVUS is more sensitive for assessing treatable iliofemoral vein stenosis compared with multiplanar venography and frequently leads to revised treatment plans and the potential for improved clinical outcome.


Subject(s)
Femoral Vein , Iliac Vein , Phlebography , Stents , Ultrasonography, Interventional , Venous Thrombosis/diagnosis , Venous Thrombosis/therapy , Adult , Aged , Aged, 80 and over , Body Mass Index , European Union , Female , Femoral Vein/diagnostic imaging , Humans , Iliac Vein/diagnostic imaging , Male , Middle Aged , Phlebography/methods , Predictive Value of Tests , Prospective Studies , Risk Factors , Sensitivity and Specificity , Treatment Outcome , Ultrasonography, Interventional/methods , United States
15.
Pol Przegl Chir ; 89(1): 33-41, 2017 Feb 28.
Article in English | MEDLINE | ID: mdl-28522791

ABSTRACT

AIM: Under the supervision of the Department of General and Vascular Surgery of Poznan University of Medical Sciences, a questionnaire was distributed online or as a paper version to medical students (MSs) in order to better understand the attitudes towards surgery as a specialty and to determine the reasons why students do and do not choose vascular surgery as their career path. MATERIALS AND METHODS: The questionnaire was distributed online or as a paper version to MSs in the 3rd, 5th, and 6th year of the PUMS 6-year M.D. PROGRAM: It provided the data on the year of study, grade point average (GPA), sex, age, respondent's specialty choice, 33 questions with responses on a 1-5 Likert scale (1 was the least important reason and 5 was the most important reason), and 2 questions with socres between 0 and 4. A total of 136 Polish MSs of PUMS completed the survey. RESULTS: For MSs who choose vascular surgery as their career path, "endovascular capabilities of vascular surgery" and "higher income possibilities than a general surgeon" were the most important reasons. The "poor availability of work in other places than the vascular surgery department of your choice, few such clinics in the region" was the most important reason not to choose vascular surgery. A role of gender was also noted - 13% of male MSs classified gender as an "important factor", in contrast to 60% of female MSs. CONCLUSIONS: The findings of this study might help to develop better strategies to attract future trainees to surgical specialties, particularly vascular surgery, and improve work environment.


Subject(s)
Career Choice , Students, Medical/statistics & numerical data , Vascular Surgical Procedures/education , Adult , Clinical Competence , Education, Medical, Graduate/standards , Female , Humans , Male , Specialties, Surgical
16.
Postepy Dermatol Alergol ; 34(5): 478-484, 2017 Oct.
Article in English | MEDLINE | ID: mdl-29507564

ABSTRACT

INTRODUCTION: Peripheral microembolism is one of the most frequent causes of acute limb ischemia. In order to effectively prevent relapses it is essential to localize and eliminate the source of embolism. AIM: To evaluate the role of Duplex Doppler ultrasound examination in identifying the causes of blue toe syndrome (BTS). MATERIAL AND METHODS: The group of 165 patients with clinical symptoms of BTS on their upper limbs (n = 16) and lower limbs (n = 149) was investigated. They all underwent Duplex Doppler ultrasound of the major arteries of the extremities, where ischemic changes occurred. RESULTS: Morphological and functional changes which might be potential sources of microembolism were identified in 146 patients. These changes included significant short-length stenoses or unstable atherosclerotic plaque (n = 73), true aneurysms (n = 42) and pseudoaneurysms (n = 17). In 11 cases, pathology of vascular prostheses in the form of anastomotic aneurysms, infection and residual thrombi after fibrinolysis was detected. In all cases, Duplex diagnosis was confirmed by other imaging and intraoperative tests. CONCLUSIONS: Duplex Doppler ultrasound of the arteries in the affected limb with a full length view should be the first-line examination in diagnosing patients with BTS. In the absence of hemodynamic blood flow disturbances in the major arteries in patients with symptoms of BTS, it is advisable to start haematological tests to identify/exclude congenital or acquired thrombophilia.

17.
Article in English | MEDLINE | ID: mdl-27458492

ABSTRACT

Failure of a vascular closure device most commonly results in a hemorrhage or pseudoaneurysm formation. In this paper a rare case of severe acute limb ischemia following incorrect deployment of a clip-based closure device (Starclose SE, Abbott Vascular) in a 31-year-old woman is presented. Symptoms of acute limb ischemia occurred at the start of the ambulation, 6 h after completion of the procedure. Because of the severity of ischemia the patient was treated surgically, and limb perfusion was successfully restored. An attempt of closure of an inadvertently punctured narrow superficial femoral artery was identified as the cause of this complication.

18.
Pol Arch Med Wewn ; 126(6): 419-29, 2016 Jun 23.
Article in English | MEDLINE | ID: mdl-27362395

ABSTRACT

A close causal relationship between cancer and venous thrombosis gives rise to questions about the effect of treatment modalities, in particular of the administered drugs, in patients with cancer-related venous thrombosis. An increased risk of chemotherapy-associated venous thromboembolism (VTE) has been well documented, while the effect of heparins used in VTE treatment on the disease course and prognosis in cancer patients has not been fully elucidated. This paper discusses the outcomes of the studies conducted so far investigating the role of heparins, in particular, low-molecular-weight heparins (LMWHs), in the prevention of thrombosis in cancer patients. It also focuses on such aspects of the treatment for cancer-associated VTE as treatment duration and drugs used. The paper summarizes the often discrepant results of long-term therapies with various LMWH products, emphasising that in this specific case the class effect is rather unlikely. It also presents the possible effects of heparins administered as part of cancer treatment, and points to the effects of LMWHs on cancer that are not related to an antithrombotic effect. On the 100th anniversary of heparin discovery, it can be said that heparin is irreversibly connected with thrombosis in the course of cancer.


Subject(s)
Heparin/therapeutic use , Neoplasms/complications , Venous Thrombosis/complications , Anticoagulants/therapeutic use , Humans , Neoplasms/surgery , Surgical Procedures, Operative/adverse effects , Venous Thrombosis/diet therapy , Venous Thrombosis/etiology , Venous Thrombosis/prevention & control
19.
Kardiol Pol ; 74(8): 772-778, 2016.
Article in English | MEDLINE | ID: mdl-26965925

ABSTRACT

BACKGROUND: Although the beneficial effect of revascularisation on reduction of local clinical ischaemic symptoms has been well established, its effect on systemic vascular endothelial function has not been fully explained yet. AIM: To determine changes in endothelium-dependent flow-mediated dilatation in patients with unilateral femoropopliteal occlusion receiving medical and surgical treatment. METHODS: Seventy-nine patients with symptomatic atherosclerotic ischaemia of lower extremities, treated with endovascular procedures, with femoropopliteal graft, or receiving conservative treatment (21-day controlled treadmill training) were enrolled in the study. Ankle brachial pressure index (ABPI), skin blood flow on the feet, and flow-mediated dilatation (FMD) of brachial arteries were measured in each patient at baseline and after 90 days of follow-up. RESULTS: The ABPI, vasomotion in the myogenic frequency band, and FMD increased significantly in surgical patients. In patients after femoropopliteal bypass a significant increase of vasomotion in the endothelial frequency band was also observed. In patients receiving conservative treatment (treadmill training), vasomotion in the myogenic frequency band increased whereas the FMD remained unchanged. CONCLUSIONS: It seems that surgical treatment may contribute to reducing the risk of cardiovascular complications in patients with advanced peripheral artery disease, as a result of improving the systemic vascular endothelial function. Limiting treatment to just treadmill training increases pain-free walking distance but does not improve systemic vascular endothelial function.


Subject(s)
Atherosclerosis/surgery , Exercise Therapy , Ischemia/surgery , Lower Extremity , Aged , Ankle Brachial Index , Atherosclerosis/complications , Atherosclerosis/diagnosis , Atherosclerosis/rehabilitation , Female , Femoral Artery/surgery , Humans , Ischemia/etiology , Ischemia/rehabilitation , Male , Middle Aged , Popliteal Artery/surgery , Treatment Outcome
20.
Am J Case Rep ; 17: 43-6, 2016 Jan 25.
Article in English | MEDLINE | ID: mdl-26806053

ABSTRACT

BACKGROUND: High-resolution contrast-enhanced ultrasound is one of methods used in the detection and characterization of endoleaks, which is a frequent complication after EVAR. A new technology provided by Toshiba's AplioTM 500 ultrasound system, called Superb Micro-Vascular Imaging (SMI), is dedicated specifically to imaging very low flow states and appears to be a promising new method for detection of endoleaks. CASE REPORT: After endovascular treatment, a 68-year-old patient who had stent-graft implantation underwent clinical examinations, including contrast-enhanced ultrasound (CEUS), superb micro-vascular imaging (SMI), and computed tomographic angiography (CTA), revealing additional information about abnormal blood flow localized in the periphery of the sack of the left common iliac artery aneurysm. By using CEUS and SMI, the endoleak was clearly visible. CONCLUSIONS: This case report illustrates the potential clinical value of this advanced Doppler technology (SMI) and how it could influence clinical management.


Subject(s)
Endoleak/diagnostic imaging , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/surgery , Ultrasonography, Doppler, Color/methods , Aged , Contrast Media , Endovascular Procedures , Humans , Male , Phospholipids , Sulfur Hexafluoride
SELECTION OF CITATIONS
SEARCH DETAIL
...