Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 9(1): 14077, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31575881

ABSTRACT

In this work we study the nature of the band gap in GeSn alloys for use in silicon-based lasers. Special attention is paid to Sn-induced band mixing effects. We demonstrate from both experiment and ab-initio theory that the (direct) Γ-character of the GeSn band gap changes continuously with alloy composition and has significant Γ-character even at low (6%) Sn concentrations. The evolution of the Γ-character is due to Sn-induced conduction band mixing effects, in contrast to the sharp indirect-to-direct band gap transition obtained in conventional alloys such as Al1-xGaxAs. Understanding the band mixing effects is critical not only from a fundamental and basic properties viewpoint but also for designing photonic devices with enhanced capabilities utilizing GeSn and related material systems.

2.
Phys Med ; 39: 137-146, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28647448

ABSTRACT

PURPOSE: To demonstrate a method of simulating mammography images of the CDMAM phantom and to investigate the coefficient of variation (CoV) in the threshold gold thickness (tT) measurements associated with use of the phantom. METHODS: The noise and sharpness of Hologic Dimensions and GE Essential mammography systems were characterized to provide data for the simulation. The simulation method was validated by comparing the tT results of real and simulated images of the CDMAM phantom for three different doses and the two systems. The detection matrices produced from each of 64 images using CDCOM software were randomly resampled to create 512 sets of 8, 16 and 32 images to estimate the CoV of tT. Sets of simulated images for a range of doses were used to estimate the CoVs for a range of diameters and threshold thicknesses. RESULTS: No significant differences were found for tT or the CoV between real and simulated CDMAM images. It was shown that resampling from 256 images was required for estimating the CoV. The CoV was around 4% using 16 images for most of the phantom but is over double that for details near the edge of the phantom. CONCLUSIONS: We have demonstrated a method to simulate images of the CDMAM phantom for different systems at a range of doses. We provide data for calculating uncertainties in tT. Any future review of the European guidelines should take into consideration the calculated uncertainties for the 0.1mm detail.


Subject(s)
Gold , Mammography , Phantoms, Imaging , Radiographic Image Enhancement , Humans , Software , Uncertainty
SELECTION OF CITATIONS
SEARCH DETAIL
...