J Am Coll Radiol ; 14(3): 324-330, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28259326

ABSTRACT

PURPOSE: The aim of this study was to measure the prevalence of clinically significant extrapulmonary findings on chest CT for lung cancer screening in the National Lung Screening Trial (NLST). METHODS: Prospectively acquired data on 17,309 participants who underwent low-dose screening chest CT from August 2002 through September 2007 during the NLST were retrospectively analyzed for extrapulmonary findings. NLST radiologist readers coded such findings as "minor" or "potentially significant." On the basis of review of recorded text descriptions, extrapulmonary findings were assigned to five organ groupings (cardiovascular, thyroid, adrenal, renal, and hepatobiliary). Extrapulmonary malignancies diagnosed during screening were also identified from medical and vital status records in the same population. The prevalence rates of organ-specific findings and newly diagnosed extrapulmonary malignancies were calculated. Exemption from human subjects research review was obtained. RESULTS: Extrapulmonary findings were noted in 58.7% of CT-screened participants, and 19.6% had findings coded as potentially significant. The prevalence of potentially significant abnormalities was highest for cardiovascular findings (8.5%), followed by renal (2.4%), hepatobiliary (2.1%), adrenal (1.2%), and thyroid (0.6%) findings. Sixty-seven of 17,309 participants (0.39%) had primary extrathoracic cancers diagnosed during screening. The prevalence of cancers among screened participants was 0.26% (n = 45) for kidney, 0.08% (n = 14) for thyroid, and 0.05% (n = 8) for liver cancers. CONCLUSIONS: One in five patients screened with CT for lung cancer will have extrapulmonary findings potentially requiring further evaluation. Indiscriminate workups of incidental extrapulmonary findings could place a significant burden on the health care system with little benefit because extrapulmonary malignancies diagnosed during screening are uncommon. Radiologists reporting screening CT should be familiar with existing recommendations for incidental findings from the ACR white papers.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Neoplasm Metastasis/diagnostic imaging , Neoplasm Metastasis/pathology , Tomography, X-Ray Computed/methods , Aged , Early Detection of Cancer , Female , Humans , Incidental Findings , Lung Neoplasms/epidemiology , Male , Middle Aged , Prevalence , Retrospective Studies , United States/epidemiology
2.
Otolaryngol Head Neck Surg ; 154(5): 847-53, 2016 05.
Article in English | MEDLINE | ID: mdl-26932954

ABSTRACT

OBJECTIVE: To determine the prevalence of missed lesions for parathyroid 4-dimensional computed tomography (4D CT) and scintigraphy and to describe the factors leading to missed lesions for both modalities. STUDY DESIGN: Case series with chart review. SETTING: Single center, hospital based. SUBJECTS AND METHODS: Forty patients undergoing 4D CT and scintigraphy before parathyroidectomy between July 2009 and October 2013 were included. Radiology reports and imaging were reviewed and correlated with operative notes to identify cases with missed lesions and the reasons for those misses. All lesions were then classified according to the following factors: multigland disease, lesion size, patient body weight, and multinodular goiter. RESULTS: Of the 40 patients, 6 had multigland disease, resulting in 51 lesions; 12 and 29 lesions were missed on 4D CT and scintigraphy, respectively. The sensitivity for detection of all lesions was 76% for 4D CT and 43% for scintigraphy. Sensitivities for single-gland disease were 88% for 4D CT and 50% for scintigraphy. Sensitivities for multigland disease were 53% for 4D CT and 24% for scintigraphy. Rates of multigland disease in patients with missed lesions were 75% on 4D CT and 48% on scintigraphy, as compared with patients with detected lesions, 23% and 18%, respectively (P ≤ .04). Mean weight of lesions missed on 4D CT was 0.3 and 0.6 g in detected lesions (P = .15). Mean weight of lesions missed on scintigraphy was 0.4 and 0.8 g in detected lesions (P = .03). CONCLUSION: 4D CT has higher sensitivity than scintigraphy. Missed lesions are more likely to occur with multigland disease for both modalities and in smaller lesions for scintigraphy.


Subject(s)
Diagnostic Errors/statistics & numerical data , Four-Dimensional Computed Tomography/methods , Parathyroid Diseases/diagnostic imaging , Tomography, Emission-Computed, Single-Photon/methods , Female , Humans , Male , Middle Aged , Parathyroid Diseases/surgery , Parathyroidectomy , Radiopharmaceuticals , Sensitivity and Specificity
3.
AJR Am J Roentgenol ; 205(6): 1281-7, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26587935

ABSTRACT

OBJECTIVE: The objective of this study was to determine the proportion of incidental thyroid nodules (ITNs) reported on CT or MRI that receive additional workup and the factors that influence workup. A secondary aim was to evaluate the effect of the American College of Radiology (ACR) white paper recommendations for reporting of ITNs. MATERIALS AND METHODS: We retrospectively reviewed patients with ITNs reported on CT or MRI studies over 12 months. We identified patients with ITNs that underwent workup and the factors associated with workup. The ACR white paper recommendations were retrospectively applied to estimate how their use would have changed the number of nodules reported in the impression section of radiology reports and the number of cancers diagnosed. The recommendations are based on suspicious imaging features, patient age, and nodule size. RESULTS: A total of 375 patients had ITNs reported. For 138 of these patients (37%), ITNs were reported by radiologists in the impression section of their reports; 26 patients (19%) received workup. Patients with ITNs reported in the impression section were 14 times more likely to undergo workup than were patients with ITNs reported only in the findings section of the radiology report. On multivariate analysis, the only factors associated with workup were younger patient age and larger nodule size (p ≤ 0.002). The ACR recommendations resulted in a 54% reduction in the number of ITNs reported in the impression section and one missed papillary cancer (TNM classification T1bN0M0). CONCLUSION: Only one in five patients with ITNs reported in the impression section of CT or MRI reports underwent additional workup, and this decision was influenced by younger patient age and larger nodule size. These factors are components of the ACR recommendations, which have the potential to reduce the number of reported ITNs and improve the standardization of radiology reporting.


Subject(s)
Magnetic Resonance Imaging , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Tomography, X-Ray Computed , Aged , Biopsy , Female , Humans , Incidental Findings , Male , Middle Aged , Retrospective Studies , Thyroid Neoplasms/diagnostic imaging , Thyroid Nodule/diagnostic imaging
4.
Thyroid ; 24(12): 1772-8, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25203387

ABSTRACT

BACKGROUND: A 3-tiered system has been proposed by radiologists for the reporting and workup of incidental thyroid nodules (ITN) detected on computed tomography (CT), magnetic resonance imaging (MRI), or positron emission tomography/computed tomography (PET/CT). It has been shown to reduce the workup rate, but there remains concern about missed malignancies. This study aims at estimating the proportion of incidental cancers that would be missed relative to all thyroid cancers if the 3-tiered system were applied to ITN seen on CT, MRI, or PET/CT. We also aim to characterize these missed incidental cancers by histology and tumor stage. METHODS: A retrospective review was performed of 680 consecutive patients with thyroid cancer who underwent surgery between January 2003 and December 2012. Medical records were reviewed to identify incidental thyroid cancers detected on imaging. Patients with incidental cancers detected on CT, MRI, or PET/CT were categorized according to the system as 3-tiered system-positive and 3-tiered system-negative. The system recommends that only 3-tiered system-positive ITN undergo further workup with ultrasound. Three-tiered system-negative cancers were the cancers that would have been missed if the system were used in practice. These tumors are described by tumor type, size, and stage to determine the potential impact if the 3-tiered system were adopted. RESULTS: One hundred and one patients had imaging-detected incidental cancers, of whom 64 met the inclusion criteria and were originally detected on CT, MRI, or PET/CT. Eight were 3-tiered system-negative, which represents 13% of the 64 incidental cancers that could be categorized and 1.2% of all thyroid cancers treated at our institution in the 10-year period. Three-tiered system-negative tumors were all papillary in histology and had a median size of 12 mm (interquartile range 10-12 mm). Six tumors (75%) were American Joint Committee on Cancer (AJCC) stage I, one was AJCC stage II, and one was AJCC stage III at diagnosis. CONCLUSIONS: Based on thyroid cancers diagnosed during a decade, incidental malignancies missed by the 3-tiered system represent 1.2% of all thyroid malignancies. Three-tiered system-negative incidental cancers were all small papillary cancers. Given that few cancers would be missed and most are less aggressive, we propose that the 3-tiered system could be adopted in clinical practice to guide the workup of ITN identified on CT, MRI, and PET/CT.


Subject(s)
Thyroid Gland/pathology , Thyroid Neoplasms/diagnosis , Thyroid Nodule/diagnosis , Adult , Aged , Female , Humans , Incidental Findings , Magnetic Resonance Imaging , Male , Middle Aged , Positron-Emission Tomography , Retrospective Studies , Thyroid Gland/diagnostic imaging , Thyroid Neoplasms/diagnostic imaging , Thyroid Neoplasms/pathology , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Tomography, X-Ray Computed
5.
AJR Am J Roentgenol ; 202(3): 602-7, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24555597

ABSTRACT

OBJECTIVE: The Society of Radiologists in Ultrasound (SRU) recommendations on thyroid nodules are intended to "diagnose thyroid cancers that have reached clinical significance, while avoiding unnecessary tests and surgery in patients with benign nodules." The aim of our study was to determine the proportion of thyroid nodules undergoing ultrasound-guided fine-needle aspiration (FNA) that do not meet SRU recommendations. MATERIALS AND METHODS: This study is a retrospective study of 400 consecutive ultrasound-guided thyroid FNA encounters from July 2010 through June 2011. An encounter was defined as presentation to the department of radiology on a given date for FNA of one or more thyroid nodules. The criteria for performing biopsy of a nodule were determined by the referring clinicians. Nodules were categorized on the basis of sonographic findings as meeting SRU recommendations for biopsy, which we refer to as "SRU-positive," or not, which we refer to as "SRU-negative." Patients without a definitive pathology diagnosis of Bethesda class benign or malignant nodules were excluded. The characteristics of malignancies were compared for SRU-positive and SRU-negative encounters. RESULTS: The final study group consisted of 360 biopsy encounters for 350 patients and 29 malignancies (8%). Of the 360 biopsy encounters, 86 (24%) were SRU-negative encounters. Malignancy rates in SRU-positive and SRU-negative encounters were 9% (24/274) and 6% (5/86), respectively, and were not significantly different (p=0.5). Eighteen malignancies (75%) in the SRU-positive group were localized, whereas the others had nodal metastases (4/24) or distant metastases (2/24). SRU-positive encounters included medullary carcinoma, anaplastic carcinoma, and melanoma metastasis in addition to papillary carcinoma. All SRU-negative malignancies were localized papillary carcinomas. CONCLUSION: One in four thyroid biopsy encounters at our institution did not meet SRU recommendations for biopsy. The application of SRU recommendations reduces the number of benign nodules that undergo workup. Potentially missed malignancies in SRU-negative nodules are less aggressive by histologic type and stage compared with SRU-positive malignancies.


Subject(s)
Endoscopic Ultrasound-Guided Fine Needle Aspiration/statistics & numerical data , Endoscopic Ultrasound-Guided Fine Needle Aspiration/standards , Medical Oncology/standards , Radiology/standards , Thyroid Nodule/epidemiology , Thyroid Nodule/pathology , Adolescent , Aged , Aged, 80 and over , Child , Female , Guideline Adherence/statistics & numerical data , Humans , Male , Middle Aged , North Carolina/epidemiology , Practice Guidelines as Topic , Prevalence , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Unnecessary Procedures/standards , Unnecessary Procedures/statistics & numerical data , Workload/statistics & numerical data , Young Adult
6.
J Neuroimaging ; 24(1): 95-8, 2014.
Article in English | MEDLINE | ID: mdl-22211876

ABSTRACT

BACKGROUND AND PURPOSE: This case involves a common disease, allergic fungal sinusitis (AFS), with the uncommon complication of intracranial abscess. Although AFS is known to result in bone erosion, invasive complications are rare. METHODS: The clinical and pathologic information were reviewed. A literature review was performed to clarify the clinical, radiologic, and pathologic features of AFS. RESULTS: The clinical and radiographic presentations were typical for AFS, including the relatively common complication of sinus wall erosion. Follow-up imaging demonstrated spread of fungal disease into the adjacent masticator space and intracranial spread by foramen ovale. CONCLUSION: This case illustrates the importance of identifying AFS and describing findings such as sinus erosion that may alter management. In this example, knowledge of the altered anatomy and potential for mucosal injury may facilitate surgical planning and decrease the likelihood of future complications.


Subject(s)
Brain Abscess/diagnostic imaging , Brain Abscess/etiology , Mycoses/diagnostic imaging , Rhinitis, Allergic/complications , Rhinitis, Allergic/diagnostic imaging , Sinusitis/complications , Sinusitis/diagnostic imaging , Adolescent , Female , Humans , Mycoses/complications , Radiography
7.
Radiology ; 269(3): 810-5, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24046441

ABSTRACT

PURPOSE: To determine whether ownership of magnetic resonance (MR) imaging equipment by ordering physicians affects the likelihood of positive findings at MR imaging of the knee and to evaluate rates of knee abnormalities seen at MR imaging as a metric for comparison of utilization. MATERIALS AND METHODS: The institutional review board approved this retrospective HIPAA-compliant study and waived the need for informed consent. A retrospective review was performed of consecutive diagnostic MR images of the knee interpreted by one radiology practice between January and April 2009 for patients who had been referred by two separate physician groups serving the same geographic community: one with financial interest (FI) in the MR imaging equipment used and one with no FI (NFI) in the MR imaging equipment used. The percentage of examinations with negative results was tabulated for both groups, and the relative frequency of each abnormality subtype was calculated among the studies with positive findings in each group. To examine frequency differences among groups, χ(2) tests were used, and to examine mean differences among groups, t tests were used. RESULTS: Of 700 examinations, 205 had negative results (117 of 350 in the FI group and 88 of 350 in the NFI group, P = .016). Among the examinations with positive results, the mean total number of positive abnormality subtypes per image did not significantly differ between groups: 1.52 for the FI group and 1.53 for the NFI group (P = .96). CONCLUSION: MR images of the knee among patients referred by the FI group were significantly more likely to be negative than those among patients referred by the NFI group. Frequency of abnormality subtype and distribution among examinations with positive results suggests a highly similar distribution and severity of abnormalities between the two patient groups.


Subject(s)
Knee/pathology , Magnetic Resonance Imaging/statistics & numerical data , Physician Self-Referral , Practice Patterns, Physicians'/statistics & numerical data , Adult , Female , Humans , Magnetic Resonance Imaging/instrumentation , Male , Ownership , Retrospective Studies , Utilization Review
8.
AJR Am J Roentgenol ; 201(3): 605-10, 2013 Sep.
Article in English | MEDLINE | ID: mdl-23971453

ABSTRACT

OBJECTIVE: The purpose of this article is to determine whether ownership of MRI equipment by ordering physicians influences the frequency of negative shoulder MRI scans. MATERIALS AND METHODS: A retrospective review was performed of 1140 consecutive shoulder MRI scans ordered by two separate referring physician groups serving the same geographic community. The first group (financially incentivized) owned the scanners used and received technical fees for their use. The second group (non-financially incentivized) did not own the scanners used and had no direct financial interest. All examinations were performed with identical protocols and were interpreted by a single radiologist group without financial interest in the imaging equipment used. The frequency of negative examinations and the number of abnormalities in each positive study was tabulated for each group. RESULTS: A total of 1140 shoulder MRI scans met inclusion criteria; 255 were negative (142 for the financially incentivized group and 113 for the non-financially incentivized group). There were 25.6% more negative scans in the financially incentivized group (p=0.047). There was no statistically significant difference in the average number of lesions per positive scan (1.67 for the financially incentivized group and 1.71 for the non-financially incentivized group; p=0.34). No statistically significant difference was found in the frequency of 19 of 20 examined lesions. CONCLUSION: Shoulder MRI examinations referred by physicians with a financial interest in the imaging equipment used were significantly more likely to be negative. Positive examinations exhibited no statistically significant difference in the number of lesions per scan or in the frequency of 19 of 20 lesion subtypes. This finding suggests a highly similar distribution and severity of disease among the two patient groups.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/statistics & numerical data , Ownership , Shoulder , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Magnetic Resonance Imaging/economics , Male , Middle Aged , Retrospective Studies
9.
AJR Am J Roentgenol ; 198(6): 1375-9, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22623551

ABSTRACT

OBJECTIVE: Financial interest in imaging equipment may affect the imaging referral patterns of ordering physicians. The purpose of this article is to determine whether ownership of MRI equipment by ordering physicians predicts the likelihood and prevalence of positive findings on lumbar spine MRI as a metric for comparison of utilization. MATERIALS AND METHODS: A retrospective review was performed of 500 consecutive diagnostic lumbar spine MRI examinations in one radiology practice ordered by two separate referring physician groups serving the same geographic community: one with financial interest in the MRI equipment used (financial-interest group) and one without financial interest in the MRI equipment used (no-financial-interest group). Negative examinations and total number of lesions per positive study were recorded for each group. RESULTS: Five hundred scans met inclusion criteria during the study period (250 in the financial-interest group and 250 in the no-financial-interest group). The negative scan frequency was 86% higher in the financial-interest group (p < 0.0001). Among positive scans, there was no significant difference in the average total number of positive lesions per scan (3.93 for the financial-interest group and 4.31 for the no-financial-interest group; p = 0.132). The average age of patients imaged by the financial-interest group was 49.8 years, versus 56.9 years for the no-financial-interest group (p < 0.0001). CONCLUSION: Lumbar spine MRI examinations referred by the financial-interest group were significantly more likely to be negative than those referred by the no-financial-interest group. Lesion frequency among positive scans suggests similar severity of disease between the two patient populations. Patients imaged by the financial-interest group were significantly younger than those imaged by the no-financial-interest group.


Subject(s)
Lumbar Vertebrae , Magnetic Resonance Imaging/economics , Magnetic Resonance Imaging/statistics & numerical data , Physician Self-Referral/statistics & numerical data , Spinal Diseases/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Chi-Square Distribution , Female , Humans , Male , Middle Aged , Ownership , Retrospective Studies , Statistics, Nonparametric
10.
AJR Am J Roentgenol ; 198(5): 1132-8, 2012 May.
Article in English | MEDLINE | ID: mdl-22528904

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the difference in absorbed organ dose and image quality for MDCT neck protocols using automatic tube current modulation alone compared with organ-based dose modulation and in-plane thyroid bismuth shielding. MATERIALS AND METHODS: An anthropomorphic female phantom with metal oxide semiconductor field effect transistor (MOSFET) detectors was scanned on a 64-MDCT scanner. The protocols included a reference neck CT protocol using automatic tube current modulation and three modified protocols: organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield. Image noise was evaluated quantitatively with the SD of the attenuation value, and subjectively by two neuroradiologists. RESULTS: Organ-based dose modulation, automatic tube current modulation with thyroid shield, and organ-based dose modulation with thyroid shield protocols reduced the thyroid dose by 28%, 33%, and 45%, respectively, compared with the use of automatic tube current modulation alone (p ≤ 0.005). Organ-based dose modulation also reduced the radiation dose to the ocular lens (33-47%) compared with the use of automatic tube current modulation (p ≤ 0.04). There was no significant difference in measured noise and subjective image quality between the protocols. CONCLUSION: Both organ-based dose modulation and thyroid shields significantly reduce the thyroid organ dose without degradation of subjective image quality compared with automatic tube current modulation. Organ-based dose modulation has the additional benefit of dose reduction to the ocular lens.


Subject(s)
Radiation Dosage , Radiation Protection/instrumentation , Thyroid Gland/radiation effects , Tomography, X-Ray Computed , Body Burden , Female , Humans , Neck , Phantoms, Imaging , Radiometry , Software
11.
Semin Ultrasound CT MR ; 33(2): 150-7, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22410363

ABSTRACT

The incidental thyroid nodule is a common finding on cross-sectional imaging of the neck and chest. Although the majority of nonpalpable incidental nodules are benign, the radiologist must assess the risk of malignancy, intelligently report the finding, and potentially direct the subsequent workup. To do so, the radiologist requires an understanding of issues around thyroid cancer, costs of thyroid nodule workup, and suspicious findings for malignancy. This article describes the problem of the incidental thyroid nodule, reviews the imaging findings of malignancy, and discusses an approach to reporting the incidental thyroid nodule.


Subject(s)
Diagnostic Imaging/methods , Thyroid Nodule/diagnosis , Humans , Incidental Findings
12.
AJR Am J Roentgenol ; 198(3): 621-7, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22358002

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the effect of peak kilovoltage on radiation dose and image quality in adult neck MDCT. MATERIALS AND METHODS: An anthropomorphic phantom with metal oxide semiconductor field effect transistor detectors was imaged with a 64-MDCT scanner. The reference CT protocol called for 120 kVp, and images obtained with that protocol were compared with CT images obtained with protocols entailing 80, 100, and 140 kVp. All imaging was performed with automatic tube current modulation. Organ dose and effective dose were determined for each protocol and compared with those obtained with the 120-kVp protocol. Image noise was evaluated objectively and subjectively for each protocol. RESULTS: The highest organ doses for all protocols were to the thyroid, ocular lens, skin, and mandible. The greatest reductions in organ dose were for the bone marrow of the cervical spine and mandible: 43% and 35% with the 100-kVp protocol and 63% and 53% with the 80-kVp protocol. Effective dose decreased as much as 9% with the 100-kVp protocol and 12% with the 80-kVp protocol. Use of the 140-kVp protocol was associated with an increase in organ dose as high as 64% for bone marrow in the cervical spine and a 19% increase in effective dose. Image noise increased with lower peak kilovoltage. The measured noise difference was greatest at 80 kVp, absolute increases were less than 2.5 HU. There was no difference in subjective image quality among protocols. CONCLUSION: Reducing the voltage from 120 to 80 kVp for neck CT can result in greater than 50% reduction in the absorbed organ dose to the bone marrow of the cervical spine and mandible without impairment in subjective image quality.


Subject(s)
Neck/diagnostic imaging , Tomography, Spiral Computed/methods , Adult , Humans , Phantoms, Imaging , Radiation Dosage , Radiation Protection , Radiographic Image Interpretation, Computer-Assisted , Reference Values
13.
AJR Am J Roentgenol ; 197(5): W904-9, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22021540

ABSTRACT

OBJECTIVE: The purpose of this study was to identify an optimal cross-sectional neck diameter that correlates with image quality and radiation exposure in MDCT examinations of the neck performed with automatic tube current modulation. MATERIALS AND METHODS: Ninety-six adults underwent 64-MDCT of the neck with automatic tube current modulation at the same noise setting. On frontal and lateral scout images, maximal body diameters were measured in the transverse and anteroposterior planes at two levels: just below the mandible (upper neck) and at the lung apex (lower neck). Neck diameters were correlated with image quality on a subjective 4-point scale and with radiation exposure (volume CT dose index). RESULTS: As continuous variables, both anteroposterior and transverse diameters in the lower neck were associated with image quality (p ≤ 0.0012). Diameters in the upper neck were not associated with image quality. When diameters in the lower neck were categorized into small, medium, and large, image quality grades were higher for smaller patients (p < 0.001). Images of 81% of small patients (lower neck transverse diameter < 40 cm) had a high image quality grade, compared with images of 7-20% of large patients (diameter > 48 cm). Transverse diameter in the lower neck correlated best with radiation dose measured as volume CT dose index (r = 0.78). When transverse diameter in the lower neck was used to categorize patients' size, the mean volume CT dose index for small patients was 34.1 mSv and that for large patients was 63.5 mSv. CONCLUSION: Lower neck transverse diameter on the CT scout image best correlates with image quality and radiation exposure for neck MDCT examinations performed with automatic tube current modulation. Images of patients with a lower neck transverse diameter less than 40 cm are of higher quality than those of larger patients. Individualized dose reduction techniques therefore may be appropriate for smaller patients.


Subject(s)
Neck/diagnostic imaging , Radiation Dosage , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Humans , Male , Middle Aged , Radiographic Image Interpretation, Computer-Assisted , Retrospective Studies , Statistics, Nonparametric
14.
AJR Am J Roentgenol ; 197(4): 778-82, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21940563

ABSTRACT

OBJECTIVE: The purpose of this article is to compare the radiation dose of conventional fluoroscopy-guided lumbar epidural steroid injections (ESIs) and CT fluoroscopy (CTF)-guided lumbar ESI using both clinical data and anthropomorphic phantoms. MATERIALS AND METHODS: We performed a retrospective review of dose parameters for 14 conventional fluoroscopy ESI procedures performed by one proceduralist and 42 CTF-guided ESIs performed by three proceduralists (14 each). By use of imaging techniques similar to those for our clinical cohorts, a commercially available anthropomorphic male phantom with metal oxide semiconductor field effect transistor detectors was scanned to obtain absorbed organ doses for conventional fluoroscopy-guided and CTF-guided ESIs. Effective dose (ED) was calculated from measured organ doses. RESULTS: The mean conventional fluoroscopy time for ESI was 37 seconds, and the mean procedural CTF time was 4.7 seconds. Calculated ED for conventional fluoroscopy was 0.85 mSv compared with 0.45 mSv for CTF. The greatest contribution to the radiation dose from CTF-guided ESI came from the planning lumbar spine CT scan, which had an ED of 2.90 mSv when z-axis ranged from L2 to S1. This resulted in a total ED for CTF-guided ESI (lumbar spine CT scan plus CTF) of 3.35 mSv. CONCLUSION: The ED for the CTF-guided ESI was almost half that of conventional fluoroscopy because of the shorter fluoroscopy time. However, the overall radiation dose for CTF-guided ESIs can be up to four times higher when a full diagnostic lumbar CT scan is performed as part of the procedure. Radiation dose reduction for CTF-guided ESI is best achieved by minimizing the dose from the preliminary planning lumbar spine CT scan.


Subject(s)
Fluoroscopy/methods , Injections, Epidural , Injections, Spinal , Low Back Pain/drug therapy , Radiation Dosage , Radiography, Interventional/methods , Steroids/administration & dosage , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Lumbar Vertebrae , Male , Phantoms, Imaging , Retrospective Studies , Time Factors
15.
AJR Am J Roentgenol ; 196(4): W426-32, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21427307

ABSTRACT

OBJECTIVE: The purpose of this article is to describe a practical imaging approach to evaluating collections in the retropharyngeal space. CONCLUSION: The differential diagnoses for fluid in the retropharyngeal space include both noninfectious and infectious processes. The multiplanar capabilities of CT and MRI are ideal for characterizing and delineating collections. In this pictorial essay, we describe the anatomy of the retropharyngeal space and offer a four-step approach to evaluating retropharyngeal collections on multiplanar imaging.


Subject(s)
Magnetic Resonance Imaging , Pharyngeal Diseases/diagnosis , Retropharyngeal Abscess/diagnosis , Tomography, X-Ray Computed , Cellulitis/diagnosis , Contrast Media , Diagnosis, Differential , Edema/diagnosis , Humans
16.
AJR Am J Roentgenol ; 195(4): 1002-6, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20858831

ABSTRACT

OBJECTIVE: The purpose of this study is to evaluate the CT densities of small head and neck mucosal cancers as a means of deriving a CT mucosal window display of narrower window width and higher window level to better detect and delineate head and neck carcinomas. MATERIALS AND METHODS: We retrospectively studied 19 subjects with T1-2 head and neck carcinomas. The density of tumor and adjacent normal mucosa on CT were measured. CT scans for the 19 patients with tumors and 35 subjects without mucosal tumors were anonymized and interpreted by two readers using standard soft-tissue windows and were reviewed again 1 week later with the addition of mucosal windows. RESULTS: The mean (± SD) attenuation of 17 visible tumors was 85.5 ± 18.3 Hounsfield units (HU) and that of the surrounding normal mucosa was 55.3 ± 15.2 HU (p < 0.0001). From our data, we derived guideline mucosal window settings-a window width of 120 HU and a window level of 60 HU. On blinded review, reader A detected 12 tumors with the addition of mucosal windows (sensitivity, 63%; specificity, 82%) and nine tumors on soft-tissue windows alone (sensitivity, 47%; specificity, 94%). Reader B detected nine tumors with use of mucosal windows (sensitivity, 47%; specificity, 71%) and eight tumors on soft-tissue windows alone (sensitivity, 42%; specificity, 74%). CONCLUSION: Early T-stage tumors have higher CT density than normal mucosa. Their conspicuity can be amplified using display windows with narrower window width and higher window level. The potential clinical applications are for the improved detection of unknown primary tumors and delineation of a known mucosal tumor.


Subject(s)
Carcinoma, Squamous Cell/diagnostic imaging , Carcinoma, Squamous Cell/pathology , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/pathology , Tomography, X-Ray Computed/methods , Aged , Case-Control Studies , Female , Humans , Male , Middle Aged , Mucous Membrane/diagnostic imaging , Mucous Membrane/pathology , Neoplasm Staging , Retrospective Studies
17.
AJR Am J Roentgenol ; 194(6): W527-36, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20489073

ABSTRACT

OBJECTIVE: The purpose of this essay is to present a systematic approach to the use of coronal, axial, and sagittal images for CT evaluation of the sinuses before functional endoscopic sinus surgery (FESS). CONCLUSION: We present a systematic approach to the use of coronal, axial, and sagittal images in CT evaluation before FESS. Each imaging plane is valuable for displaying anatomic variants, which can predispose a patient to recurrent disease and affect the surgical approach, and critical variants, which can make surgery hazardous.


Subject(s)
Endoscopy/methods , Paranasal Sinus Diseases/diagnostic imaging , Paranasal Sinus Diseases/surgery , Tomography, X-Ray Computed/methods , Humans
18.
AJNR Am J Neuroradiol ; 29(5): e23-30, 2008 May.
Article in English | MEDLINE | ID: mdl-18477656

ABSTRACT

The recent "Advanced Neuroimaging for Acute Stroke Treatment" meeting on September 7 and 8, 2007 in Washington DC, brought together stroke neurologists, neuroradiologists, emergency physicians, neuroimaging research scientists, members of the National Institute of Neurological Disorders and Stroke (NINDS), the National Institute of Biomedical Imaging and Bioengineering (NIBIB), industry representatives, and members of the US Food and Drug Administration (FDA) to discuss the role of advanced neuroimaging in acute stroke treatment. The goals of the meeting were to assess state-of-the-art practice in terms of acute stroke imaging research and to propose specific recommendations regarding: (1) the standardization of perfusion and penumbral imaging techniques, (2) the validation of the accuracy and clinical utility of imaging markers of the ischemic penumbra, (3) the validation of imaging biomarkers relevant to clinical outcomes, and (4) the creation of a central repository to achieve these goals. The present article summarizes these recommendations and examines practical steps to achieve them.


Subject(s)
Biomedical Research/trends , Image Enhancement/methods , Neuroradiography/trends , Practice Patterns, Physicians'/trends , Research/trends , Stroke/diagnosis , Acute Disease , Humans , United States
19.
Stroke ; 39(5): 1621-8, 2008 May.
Article in English | MEDLINE | ID: mdl-18403743

ABSTRACT

The recent "Advanced Neuroimaging for Acute Stroke Treatment" meeting on September 7 and 8, 2007 in Washington DC, brought together stroke neurologists, neuroradiologists, emergency physicians, neuroimaging research scientists, members of the National Institute of Neurological Disorders and Stroke (NINDS), the National Institute of Biomedical Imaging and Bioengineering (NIBIB), industry representatives, and members of the US Food and Drug Administration (FDA) to discuss the role of advanced neuroimaging in acute stroke treatment. The goals of the meeting were to assess state-of-the-art practice in terms of acute stroke imaging research and to propose specific recommendations regarding: (1) the standardization of perfusion and penumbral imaging techniques, (2) the validation of the accuracy and clinical utility of imaging markers of the ischemic penumbra, (3) the validation of imaging biomarkers relevant to clinical outcomes, and (4) the creation of a central repository to achieve these goals. The present article summarizes these recommendations and examines practical steps to achieve them.


Subject(s)
Diagnostic Imaging/standards , Diagnostic Imaging/trends , Stroke/diagnosis , Aged , Benchmarking , Biomarkers , Brain Ischemia/diagnosis , Brain Ischemia/diagnostic imaging , Brain Ischemia/pathology , Cerebrovascular Circulation , Cluster Analysis , Databases as Topic , Diagnostic Imaging/methods , Female , Guideline Adherence , Hospital Mortality , Humans , Magnetic Resonance Angiography/methods , Magnetic Resonance Angiography/standards , Magnetic Resonance Angiography/trends , Male , Perfusion/methods , Perfusion/standards , Regression Analysis , Stroke/diagnostic imaging , Stroke/pathology , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/standards , Tomography, X-Ray Computed/trends , Validation Studies as Topic
20.
Arch Neurol ; 62(12): 1904-8, 2005 Dec.
Article in English | MEDLINE | ID: mdl-16344348

ABSTRACT

BACKGROUND: Larger gray matter (GM) volume in healthy children is correlated with higher IQ. Children with neurofibromatosis type 1 (NF1) have larger brains, their magnetic resonance images frequently show T2-weighted hyperintensities, and their IQs are lower. OBJECTIVES: To confirm the hypotheses that (1) children with NF1 have larger GM and white matter volumes, (2) the greatest volume differences are in the frontal and parietal regions and in children with NF1 with hyperintensities, and (3) GM volume is inversely related to IQ in children with NF1. DESIGN: Wechsler Intelligence Scale for Children-Third Edition IQ testing and measurement of cerebral volumes and hyperintensities in brain magnetic resonance images were performed on 36 children with NF1 and on 36 matched relatives who served as control subjects. RESULTS: Gray matter and white matter volumes were significantly larger in children with NF1. The greatest difference was observed in cerebral white matter volume, predominantly in the frontal lobes, whereas the greatest difference in GM volume was in the temporal, parietal, and occipital regions. In controls, IQ was significantly related to GM volume, but in children with NF1, IQ was not inversely associated with GM volume, although IQs of children with NF1 were significantly lower. CONCLUSIONS: Children with NF1 do not have the normal relationship between GM volume and IQ. Larger GM volume in the posterior brain regions and larger white matter volumes in the frontal brain regions contribute to the larger brain volume in children with NF1.


Subject(s)
Brain/pathology , Cognition Disorders/etiology , Cognition Disorders/pathology , Nerve Fibers, Myelinated/pathology , Neurofibromatosis 1/complications , Neurofibromatosis 1/pathology , Brain/abnormalities , Brain/physiopathology , Child , Cognition Disorders/psychology , Diffusion Magnetic Resonance Imaging , Female , Humans , Hypertrophy/genetics , Hypertrophy/pathology , Hypertrophy/physiopathology , Intelligence/physiology , Intelligence Tests , Male , Motor Skills Disorders/etiology , Motor Skills Disorders/pathology , Motor Skills Disorders/psychology , Neurofibromatosis 1/physiopathology , Perceptual Disorders/genetics , Perceptual Disorders/pathology , Perceptual Disorders/psychology
SELECTION OF CITATIONS