Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Endovasc Ther ; 28(1): 107-116, 2021 02.
Article in English | MEDLINE | ID: mdl-32885736

ABSTRACT

PURPOSE: To report the results of a study evaluating JetStream atherectomy for the treatment of in-stent restenosis (ISR). MATERIALS AND METHODS: The JetStream XC atherectomy device, a rotational cutter with aspiration capacity, was evaluated in a prospective, multicenter study (JET-ISR) of 60 patients (mean age 70.2±10.8 years; 40 men) with femoropopliteal ISR (ClinicalTrials.gov identifier NCT02730234). Lesion length was 19.9±13.5 cm; 33 (55%) were chronic total occlusions and 26 (45%) were TransAtlantic Inter-Society Consensus class D. No drug-bearing device was allowed, and stenting was performed only for bailout. Lesion characteristics and stent integrity were evaluated by an independent core laboratory. The primary endpoint was target lesion revascularization (TLR) at 6 months with bailout stenting considered as TLR. Secondary endpoints included TLR (without bailout stenting) and clinical patency (no restenosis or TLR) at 1 year. The Kaplan-Meier method was employed to evaluate time-to-event endpoints; estimates are given with 95% confidence interval (CI). RESULTS: Bailout stenting was required in 6 of 60 limbs (10%). There were no stent fractures or deformities after atherectomy + adjunctive angioplasty reported by the core laboratory. Kaplan-Meier estimates of freedom from TLR at 6 months and 1 year were 79.3% (95% CI 68.9% to 89.8%) and 60.7% (95% CI 47.8% to 73.6%), respectively. When bailout stenting at the index procedure was not considered a TLR event, freedom from TLR estimates at 6 months and 1 year were 89.3% (95% CI 81.2% to 97.4%) and 66.8% (95% CI 54.3% to 74.2%), respectively. Clinical patency rates at 6 months and 1 year were 77.5% (31/40) and 51.7% (15/29), respectively. CONCLUSION: JetStream atherectomy using the XC device and no drug-eluting devices is feasible, with good clinical patency and 1-year freedom from TLR.


Subject(s)
Peripheral Arterial Disease , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Atherectomy/adverse effects , Coronary Restenosis , Female , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Humans , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/therapy , Popliteal Artery/diagnostic imaging , Popliteal Artery/surgery , Prospective Studies , Retrospective Studies , Treatment Outcome , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...