Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
J Bone Miner Res ; 35(11): 2179-2192, 2020 11.
Article in English | MEDLINE | ID: mdl-32568416

ABSTRACT

Treatment of medication-related osteonecrosis of the jaw (MRONJ) is challenging and no clear consensus has been achieved. This study investigated preventive measures recommended for tooth extractions under antiresorptive (AR) treatment and the role of discontinuation of AR therapy to avoid the onset of MRONJ in a minipig model. Thirty-six Göttingen minipigs were divided into four groups. Group 1 (negative control): tooth extractions but no zoledronate (ZOL). Group 2 (positive control): weekly ZOL infusions for 12 weeks followed by tooth extractions without wound management followed by 8 weeks of ZOL treatment. Group 3: weekly ZOL infusions for 12 weeks followed by tooth extractions; surgical wound management (resection of sharp bone edges, mucoperiosteal coverage); and continuation of ZOL infusions for 8 weeks plus antibiotic treatment. Group 4: 12 weeks of ZOL infusions followed by a drug holiday for 6 weeks. Tooth extractions with preventive wound management followed by antibiotic treatment for 8 weeks but no ZOL infusions. Jawbones were subjected to macroscopic, radiological (CT and micro-CT) and histopathological investigations. No clinical cases of MRONJ were observed in the negative group, in the positive control all animals developed MRONJ. Group 3 developed MRONJ in 83% of cases. With a drug holiday, 40% developed MRONJ in areas of tooth extraction. This is the first large animal model that reduces the occurrence of MRONJ following tooth extraction by the implementation of a drug holiday combined with antibiotic prophylaxis and smoothening of sharp bony edges. © 2020 The Authors. Journal of Bone and Mineral Research published by American Society for Bone and Mineral Research..


Subject(s)
Bisphosphonate-Associated Osteonecrosis of the Jaw , Bone Density Conservation Agents , Pharmaceutical Preparations , Animals , Bisphosphonate-Associated Osteonecrosis of the Jaw/diagnostic imaging , Bisphosphonate-Associated Osteonecrosis of the Jaw/drug therapy , Bisphosphonate-Associated Osteonecrosis of the Jaw/prevention & control , Diphosphonates/adverse effects , Swine , Swine, Miniature , Zoledronic Acid
2.
JOR Spine ; 3(1): e1074, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32211587

ABSTRACT

Tissue engineering repair of annulus fibrosus (AF) defects has the potential to prevent disability and pain from intervertebral disc (IVD) herniation and its progression to degeneration. Clinical translation of AF repair methods requires assessment in long-term large animal models. An ovine AF injury model was developed using cervical spinal levels and a biopsy-type AF defect to assess composite tissue engineering repair in 1-month and 12-month studies. The repair used a fibrin hydrogel crosslinked with genipin (FibGen) to seal defects, poly(trimethylene carbonate) (PTMC) scaffolds to replace lost AF tissue, and polyurethane membranes to prevent herniation. In the 1-month study, PTMC scaffolds sealed with FibGen herniated with polyurethane membranes. When applied alone, FibGen integrated with the surrounding AF tissue without herniation, showing promise for long-term studies. The 12-month long-term study used only FibGen which showed fibrous healing, biomaterial resorption and no obvious hydrogel-related complications. However, the 2 mm biopsy punch injury condition also exhibited fibrotic healing at 12 months. Both untreated and FibGen treated groups showed equivalency with no detectable differences in histological grades of proteoglycans, cellular morphology, IVD structure and blood vessel formation, biomechanical properties including torque range and axial range of motion, Pfirrmann grade, IVD height, and quantitative scores of vertebral body changes from clinical computed tomography. The biopsy-type injury caused endplate defects with a high prevalence of osteophytes in all groups and no nucleus herniation, indicating that the biopsy-type injury requires further refinement, such as reduction to a slit-type defect that could penetrate the full depth of the AF without damaging the endplate. Results demonstrate translational feasibility of FibGen for AF repair to seal AF defects, although future study with a more refined injury model is required to validate the efficacy of FibGen before translation.

3.
J Orthop Res ; 37(5): 1183-1191, 2019 05.
Article in English | MEDLINE | ID: mdl-30835898

ABSTRACT

Standardized and reproducible animal models are required for the assessment of bone healing mediated by biomaterials, cells, and drugs. Among the available bone-fractured models, calvarial defect is a simple and adequate option when researchers investigate intra-membranous bone formation and the influence of their regenerative solutions. However, the conventional surgical tools required to perform calvaria osteotomies (i.e., trephine bur mounted on a dental handpiece, DS) can affect the subjacent tissues of the skull, which are the dura mater and the brain. We hypothesized that the quality of the calvaria defect and the preservation of underlying tissues can be improved using a novel Anspach high-speed drill with a Codman Neuro Disposable Perforator handheld (ACP). Using a rabbit cadaveric models, we performed calvarial defects with either conventional DS or the ACP system, and showed that both techniques allowed to create standardized defects with circular geometry. We demonstrated that the ACP had clear benefices in terms of DM preservation and absence of exothermic reaction upon drilling. Even though this comparative work was conducted on cadaver, it is of substantial importance as it introduces a novel technique, easily applicable to investigate calvaria bone healing, which brings clear advantages compared to the conventional dental station. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:1-9, 2019.


Subject(s)
Craniotomy/instrumentation , Animals , Female , Osteotomy/instrumentation , Rabbits
4.
J Orthop Res ; 37(3): 541-552, 2019 03.
Article in English | MEDLINE | ID: mdl-30575124

ABSTRACT

The effect of age on implant fixation in bone is not always considered during the design of preclinical models. The decision on animal's age is often related to practical or historical reasons, which ultimately may affect the reproducibility of results. This study aimed to quantify the effect of age by monitoring the fixation of contrast-enhanced PEEK screws in rats, hypothesizing that the kinetics of fixation is impaired in older animals but that age effects are less severe than osteoporotic effects. The time course of implant fixation was investigated in healthy rats at 24, 40, and 60 weeks of age; and in ovariectomized rats. Implant fixation was monitored using in-vivo microCT and dynamic histomorphometry during 1 month. The rats were euthanized 28 days post screw insertion. The data was analyzed both in absolute value and after normalization to baseline bone mass. In absolute terms, greater age had a detrimental effect on bone implant contact, bone fraction, implant stiffness, and bone remodeling but less than ovariectomy. Interestingly, once data was normalized to baseline bone mass this effect disappeared, suggesting that the physiologic response to implant placement was not affected by age. In conclusion, implant fixation kinetics is less affected by age than by baseline bone mass in this rat model. Animals of different ages can therefore be compared but data must be construed relatively to baseline bone mass and not in absolute terms. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 9999:1-12, 2018.


Subject(s)
Aging/physiology , Osseointegration , Animals , Benzophenones , Bone Screws , Female , Longitudinal Studies , Ovariectomy , Polymers , Random Allocation , Rats, Wistar , Tibia/diagnostic imaging , Tibia/physiology , X-Ray Microtomography
5.
Article in English | MEDLINE | ID: mdl-29484293

ABSTRACT

Bone is an organ with high natural regenerative capacity and most fractures heal spontaneously when appropriate fracture fixation is provided. However, additional treatment is required for patients with large segmental defects exceeding the endogenous healing potential and for patients suffering from fracture non-unions. These cases are often associated with insufficient vascularization. Transplantation of CD34+ endothelial progenitor cells (EPCs) has been successfully applied to promote neovascularization of bone defects, however including extensive ex vivo manipulation of cells. Here, we hypothesized, that treatment with granulocyte colony-stimulating factor (G-CSF) may improve bone healing by mobilization of CD34+ progenitor cells into the circulation, which in turn may facilitate vascularization at the defect site. In this pilot study, we aimed to characterize the different cell populations mobilized by G-CSF and investigate the influence of cell mobilization on the healing of a critical size femoral defect in rats. Cell mobilization was investigated by flow cytometry at different time points after five consecutive daily G-CSF injections. In a pilot study, bone healing of a 4.5-mm critical femoral defect in F344 rats was compared between a saline-treated control group and a G-CSF treatment group. In vivo microcomputed tomography and histology were applied to compare bone formation in both treatment groups. Our data revealed that leukocyte counts show a peak increase at the first day after the last G-CSF injection. In addition, we found that CD34+ progenitor cells, including EPCs, were significantly enriched at day 1, and further increased at day 5 and day 11. Upregulation of monocytes, granulocytes and macrophages peaked at day 1. G-CSF treatment significantly increased bone volume and bone density in the defect, which was confirmed by histology. Our data show that different cell populations are mobilized by G-CSF treatment in cell specific patterns. Although in this pilot study no bridging of the critical defect was observed, significantly improved bone formation by G-CSF treatment was clearly shown.

6.
Calcif Tissue Int ; 101(3): 271-279, 2017 09.
Article in English | MEDLINE | ID: mdl-28432379

ABSTRACT

Fractures of the proximal humerus are highly related to age and osteoporotic bone remodeling. Previous studies have highlighted the cortex as a major side of the bone loss, but the microstructural changes of the humerus have not been evaluated entirely. Sixty-four (n = 64) humeri of a representative collective (18-100 years) were scanned with high-resolution peripheral quantitative computed tomography (82 µm). Bone mineral density (BMD), trabecular bone volume fraction (Tb.BV/TV), cortical thickness (Ct.Th), and cortical porosity (Ct.Po) were determined with respect to four age groups. The BMD (r = -0.42), Ct.Th (r = 0.57), and Tb.BV/TV (r = 0.68) showed an age group-related decrease, while the Ct.Po increased (r = -0.55). The oldest group (80-100 years) revealed an extensively higher Ct.Po of +87% compared to the youngest group (18-44 years), while the Ct.Th and Tb.BV/TV were significantly lower by -35 and -49% (p < 0.05). The main cortical bone loss occurred after 65 years with the Ct.Th (-34%) and Tb.BV/TV (-40%) being clearly lower and the Ct.Po (+93%) clearly higher compared to the youngest group. In summary, osteoporosis leads to an age-related higher Ct.Po and reduced Ct.Th at the humeral cortex of the surgical neck. The bone loss of the cortex predominantly occurs around the age of 65 years and is very likely to reduce the mechanical strength and highly increases the fracture risk.


Subject(s)
Aging/pathology , Bone Density , Cortical Bone/pathology , Humerus/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Cadaver , Cortical Bone/diagnostic imaging , Cross-Sectional Studies , Female , Humans , Humerus/diagnostic imaging , Male , Middle Aged , Porosity , Tomography, X-Ray Computed , Young Adult
7.
Int Orthop ; 41(8): 1607-1615, 2017 08.
Article in English | MEDLINE | ID: mdl-28144723

ABSTRACT

PURPOSE: Subchondral screw abutment in osteosynthesis of joint fractures is an effective method to achieve sufficient screw grip. In this study we investigated if subchondral screw placement is possible without harming the overlying subchondral plate and joint cartilage iatrogenic. MATERIALS AND METHODS: A 3.5-mm conventional steel screw was placed in the tibia of ten sheep in distances between 1 and 7 mm beneath the joint cartilage. After a follow up of two and four months, evaluation of the subchondral bone and joint cartilage was performed by means of a histological osteoarthritis score, HRpQCT imaging and determination of the glycosaminoglycan content in the cartilage. The control group was the contralateral knee of the same animal. RESULTS: Histomorphometric evaluation of the Mankin osteoarthritis score revealed no significant difference compared to the control after two (p = 0.102) and four months (p = 0.429). No correlation between distance of the screw to the cartilage and histological scoring was found (p = 0.658, R2 = 0.04 after two months and p = 0.171, R2 = 0.18 after four months). HRpQCT measurements of the subchondral thickness between screw and cartilage after two (p = 0.05) and four months (p = 0.424) showed no significant difference. Mean glycosaminoglycan content in the treatment group compared to the control after two months (p = 0.25) and four months (p = 0.523) was not significant different. CONCLUSION: In conclusion subchondral screw abutment did not damage the joint cartilage after a two- and four-month follow up in this sheep model.


Subject(s)
Bone Screws/adverse effects , Cartilage Diseases/pathology , Cartilage, Articular/pathology , Osteoarthritis/pathology , Tibia/pathology , Animals , Cartilage Diseases/etiology , Cartilage, Articular/chemistry , Cartilage, Articular/surgery , Glycosaminoglycans/analysis , Iatrogenic Disease , Models, Animal , Osteoarthritis/etiology , Sheep , Tibia/chemistry
8.
J Orthop Trauma ; 31(3): 131-137, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27755333

ABSTRACT

OBJECTIVES: To evaluate the biomechanical performance of femoral neck system (FNS) in comparison with established methods for fixation of femoral neck fractures in a cadaveric model. METHODS: Twenty pairs of fresh-frozen human cadaveric femora were instrumented either with dynamic hip screw and antirotation screw (DHS-screw), DHS-blade, 3 cannulated screws (3CS) or with FNS in a partially paired design. The specimens were randomized to 2 paired treatment groups based on the bone mineral density (BMD), namely DHS-screw/DHS-blade and FNS/3CS. A reduced unstable femoral neck fracture with postero-caudal comminution, OTA/AO 31-B2.3, 70 degrees Pauwels III, was simulated by cutting 30 degrees distal and 15 degrees posterior wedges. Cyclic axial loading was applied in 16 degrees adduction, starting at 500 N and with progressive peak force increase of 0.1 N/cycle until construct failure. Axial stiffness was measured in the third loading cycle. Femoral neck and leg shortening, and varus tilting and implant migration were calculated by means of optical motion tracking. RESULTS: Mean axial stiffness was 688.8 ± 132.6 N/mm for DHS-screw, 629.1 ± 94.1 N/mm for DHS-blade, 748.9 ± 211.4 N/mm for FNS, and 584.1 ± 156.6 N/mm for 3CS, with no statistical significances. Cycles until 15-mm leg shortening were comparable for DHS-Screw (20,542 ± 7465), DHS-blade (19,161 ± 3793) and FNS (17,372 ± 2996), however significantly higher than for 3CS (7293 ± 2819), P < 0.001. Similarly, cycles until 15 mm femoral neck shortening were comparable between DHS-screw (20,846 ± 7339), DHS-blade (18,974 ± 4032) and FNS (18,171 ± 2585), and significantly higher than 3CS (8039 ± 2778), P < 0.001. CONCLUSIONS: From a biomechanical point of view, the femoral neck system is a valid alternative to treat unstable femoral neck fractures, representing the advantages of a minimally invasive implant with comparable stability to the 2 DHS systems and superior to cannulated screws.


Subject(s)
Bone Screws/statistics & numerical data , Femoral Neck Fractures/physiopathology , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/instrumentation , Fractures, Malunited/physiopathology , Fractures, Malunited/surgery , Aged , Bone Screws/classification , Cadaver , Elastic Modulus , Equipment Failure Analysis , Female , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Prosthesis Design , Statistics as Topic , Tensile Strength
9.
Med Eng Phys ; 38(2): 97-107, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26686028

ABSTRACT

Vertebroplasty has been shown to reinforce weak vertebral bodies and reduce fracture risks, yet cement leakage is a major problem that can cause severe complications. Since cement flow is nearly impossible to control during surgery, small volumes of cement are injected, but then mechanical benefits might be limited. A better understanding of cement flows within bone structure is required to further optimize vertebroplasty and bone augmentation in general. We developed a novel imaging method, composite time-lapse CT, to characterize cement flow during injection. In brief, composite-resolution time-lapse CT exploits the qualities of microCT and clinical CT. The method consists in overlaying low-resolution time-lapse CT scans acquired during injection onto pre-operative high-resolution microCT scans, generating composite-resolution time-lapse CT series of cement flow within bone. In this in vitro study, composite-resolution time-lapse CT was applied to eight intact and five artificially fractured cadaveric vertebrae during vertebroplasty. The time-lapse scans were acquired at one-milliliter cement injection steps until a total of 10 ml cement was injected. The composite-resolution series were then converted into micro finite element models to compute strains distribution under virtual axial loading. Relocation of strain energy density within bone structure was observed throughout the progression of the procedure. Interestingly, the normalized effect of cement injection on the overall stiffness of the vertebrae was similar between intact and fractured specimens, although at different orders of magnitude. In conclusion, composite time-lapse CT can picture cement flows during bone augmentation. The composite images can also be easily converted into finite element models to compute virtual strain distributions under loading at every step of an injection, providing deeper understanding on the biomechanics of vertebroplasty.


Subject(s)
Bone Cements , Finite Element Analysis , Mechanical Phenomena , Vertebroplasty , Aged , Female , Humans , Image Processing, Computer-Assisted , Male , Time Factors , Tomography, X-Ray Computed
10.
Biomed Res Int ; 2014: 250958, 2014.
Article in English | MEDLINE | ID: mdl-24696845

ABSTRACT

Critical sized bone defect (CSBD) animal models are used to evaluate and confirm efficacy and potency of new treatment modalities based on bone tissue engineering before the latter can be applied in clinical practice. In this study, a bilateral CSBD model in the iliac wings of sheep is described in detail. To demonstrate that this is a large animal CSBD model in sheep, bone healing within the defect left empty (negative control) or filled with autologous corticocancellous bone graft (clinical gold standard, positive control) was assessed using micro-CT, histology, histomorphometric, and fluorochrome analysis. After three months, new bone into the defect site was formed across the whole defect in the positive controls but limited to the edge of the defects in the negative controls. Bone volume in the positive controls was statistically higher than in the negative controls, with the latter having less than 10% new bone growth. There were no intraoperative or postoperative complications. The model described here represents a reliable and reproducible bilateral CSBD in sheep with low morbidity that can be used for in vivo evaluation of new treatment modalities based on bone tissue engineering.


Subject(s)
Ilium/pathology , Tissue Engineering/methods , Animals , Bone Density , Disease Models, Animal , Female , Fluorescent Dyes/metabolism , Ilium/diagnostic imaging , Ilium/physiopathology , Imaging, Three-Dimensional , Organ Size , Sheep , X-Ray Microtomography
11.
PLoS One ; 9(2): e88946, 2014.
Article in English | MEDLINE | ID: mdl-24551194

ABSTRACT

BACKGROUND: Areal bone mineral density is predictive for fracture risk. Microstructural bone parameters evaluated at the appendicular skeleton by high-resolution peripheral quantitative computed tomography (HR-pQCT) display differences between healthy patients and fracture patients. With the simple geometry of the cortex at the distal tibial diaphysis, a cortical index of the tibia combining material and mechanical properties correlated highly with bone strength ex vivo. The trabecular bone score derived from the scan of the lumbar spine by dual-energy X-ray absorptiometry (DXA) correlated ex vivo with the micro architectural parameters. It is unknown if these microstructural correlations could be made in healthy premenopausal women. METHODS: Randomly selected women between 20-40 years of age were examined by DXA and HR-pQCT at the standard regions of interest and at customized sub regions to focus on cortical and trabecular parameters of strength separately. For cortical strength, at the distal tibia the volumetric cortical index was calculated directly from HR-pQCT and the areal cortical index was derived from the DXA scan using a Canny threshold-based tool. For trabecular strength, the trabecular bone score was calculated based on the DXA scan of the lumbar spine and was compared with the corresponding parameters derived from the HR-pQCT measurements at radius and tibia. RESULTS: Seventy-two healthy women were included (average age 33.8 years, average BMI 23.2 kg/m(2)). The areal cortical index correlated highly with the volumetric cortical index at the distal tibia (R  =  0.798). The trabecular bone score correlated moderately with the microstructural parameters of the trabecular bone. CONCLUSION: This study in randomly selected premenopausal women demonstrated that microstructural parameters of the bone evaluated by HR-pQCT correlated with the DXA derived parameters of skeletal regions containing predominantly cortical or cancellous bone. Whether these indexes are suitable for better predictions of the fracture risk deserves further investigation.


Subject(s)
Bone Density/physiology , Lumbar Vertebrae/ultrastructure , Radius/ultrastructure , Tibia/ultrastructure , Absorptiometry, Photon , Adult , Body Mass Index , Female , Fractures, Bone , Humans , Lumbar Vertebrae/diagnostic imaging , Premenopause/physiology , Radius/diagnostic imaging , Research Design , Risk , Tibia/diagnostic imaging , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...