Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Kyobu Geka ; 77(4): 311-314, 2024 Apr.
Article in Japanese | MEDLINE | ID: mdl-38644180

ABSTRACT

The patient is a 76-year-old man. His chief complaint of chest pain led to a diagnosis of pericardial effusion of unknown cause, and pericardial drainage was performed. On the 30th day, chest pain appeared again. Echocardiography revealed a pericardial fluid reaccumulation and a substantial mass in the pericardial space. Surgical drainage was performed to find the cause. A hematoma/mass was present on the epicardium. The pericardial sac was filled with hematoma. The hematoma was removed, but part of the mass infiltrated close to the anterior descending branch of the left coronary artery, and removal of that part was abandoned. The intrapericardial hematoma and epicardium were submitted to pathology leading to the diagnosis of synovial sarcoma. The patient was discharged home 14 days after surgery.


Subject(s)
Heart Neoplasms , Pericardial Effusion , Sarcoma, Synovial , Humans , Male , Sarcoma, Synovial/complications , Sarcoma, Synovial/surgery , Sarcoma, Synovial/diagnostic imaging , Pericardial Effusion/etiology , Pericardial Effusion/diagnostic imaging , Pericardial Effusion/surgery , Aged , Heart Neoplasms/complications , Heart Neoplasms/surgery , Heart Neoplasms/diagnostic imaging , Recurrence
2.
Heart Vessels ; 39(6): 549-555, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38393378

ABSTRACT

The long-term safety, efficacy, and outcomes of low-intensity anticoagulation for mechanical heart valves remain unclear. This study aimed to evaluate the long-term outcomes of low-intensity anticoagulation therapy after aortic valve replacement (AVR) with a mechanical prosthesis. This retrospective cohort study consulted medical records and conducted a questionnaire to investigate 519 patients who underwent single AVR with the St. Jude Medical bileaflet valve and were in sinus rhythm. All patients were followed up with an international normalized ratio (INR) target of 1.6-2.5, and their INR values were checked throughout the follow-up period. The survival rate, incidence of major adverse cardiac and cerebrovascular events (MACCE), and risk factors for cardiac death and MACCE were investigated. The total follow-up was 9793 patient-years, and the follow-up periods were 19.9 (standard deviation [SD]: 7.9) years. The mean INR was 2.03 (SD: 0.54). Survival rates from cardiac death were 93.6% in 20 years and 85.2% in 30 years. Advanced age ≥ 70 years was the only significant risk factor for cardiac death and MACCE, and the INR < 2.0 was not significant risk factor for MACCE including thromboembolism or bleeding events. Low-intensity anticoagulation with an INR of 1.6-2.5 for patients with sinus rhythm after AVR with a bileaflet mechanical valve is safe and effective, even over 30 years.


Subject(s)
Anticoagulants , Aortic Valve , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Humans , Male , Female , Retrospective Studies , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Anticoagulants/administration & dosage , Aged , Aortic Valve/surgery , Risk Factors , Middle Aged , Treatment Outcome , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Time Factors , International Normalized Ratio , Follow-Up Studies , Prosthesis Design , Survival Rate/trends , Thromboembolism/prevention & control , Thromboembolism/etiology , Thromboembolism/epidemiology , Incidence , Postoperative Complications/epidemiology
3.
Kyobu Geka ; 76(8): 633-637, 2023 Aug.
Article in Japanese | MEDLINE | ID: mdl-37500552

ABSTRACT

An 89-year-old man who had undergone aortic valve replacement with a 21 mm Mosaic bioprosthetic valve at another hospital 14 years ago was admitted to the emergency room for a sudden respiratory distress two days prior and was diagnosed with severe aortic regurgitation( AR) caused by valve insufficiency and acute heart failure secondary to low cardiac function. Upon admission, he was found to have severe hypoxia with PaO2 of 40 mmHg range, and transcatheter aortic valve replacement (TAVI, TAV in SAV) with a 20 mm SAPIEN3 was performed under local anesthesia for fear of hypotension while under general anesthesia. After confirming that AR had completely disappeared, the patient was intubated and discharged from the operating room on a mechanical ventilator. The patient was weaned from the ventilator on the second postoperative day and was transferred to the other hospital for rehabilitation, 48 days postoperatively. Although there is no report on the comparative study of anesthesia methods for emergency transcatheter aortic valve implantation( TAVI), TAVI under regional anesthesia is minimally invasive with a lower risk for hypotension than general anesthesia. Therefore, we believe it is useful for patients with acute heart failure and hypotension. In addition, it is important to use a balloon expandable valve with excellent implantability to complete the procedure in a short time.


Subject(s)
Aortic Valve Stenosis , Heart Failure , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Hypotension , Transcatheter Aortic Valve Replacement , Male , Humans , Aged, 80 and over , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Anesthesia, Local , Aortic Valve Stenosis/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Hypotension/etiology , Hypotension/surgery , Heart Failure/etiology , Heart Failure/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...