Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Electr Bioimpedance ; 13(1): 143-149, 2022 Jan.
Article in English | MEDLINE | ID: mdl-36699664

ABSTRACT

Fast and reliable bioimpedimetric measurements are of growing importance in many practical applications. In this work we used a measurement method in time domain by processing the step response of the biological system under test. In order to decrease the data volume and computation time while retaining all relevant information the step response is sampled non-uniformly. Consequently, fast Fourier transform cannot be directly used for spectrum calculation and non-conventional data processing algorithms for transforming measured data into the frequency domain are required. In this paper we present corresponding computational methods. They are split into two groups. The first group is oriented on calculating the local approximation of the measured step response with a set of proper functions and calculating its spectrum via analytical Fourier transform, thus yielding a relatively versatile approach for estimating the impedance spectrum. In this case, the choice of approximating functions that suit known a priori properties of the measured signals are of great importance. A second group of methods relies on the evaluation of important signal parameters directly in the time domain. In this case we use a priori information about the measurement object in the form of an underlying model. After that the model is fitted to the measured data and thus, parameter values are extracted. Practical aspects, advantages and drawbacks of all considered data processing steps are revealed when applying them to the measurements made with real biological objects.

2.
J Electr Bioimpedance ; 11(1): 49-56, 2020 Jan.
Article in English | MEDLINE | ID: mdl-33584903

ABSTRACT

Designing proper frontend electronics is critical in the development of highly sophisticated electrode systems. Multielectrode arrays for measuring electrical signals or impedance require multichannel readout systems. Even more challenging is the differential or ratiometric configuration with simultaneous assessment of measurement and reference channels. In this work, an eight-channel frontend was developed for contacting a 2×8 electrode array (8 measurement and 8 reference electrodes) with a large common electrode to the impedance gain-phase analyzer Solartron 1260 (S-1260). Using the three independent and truly parallel monitor channels of the S-1260, impedance of trapped cells and reference material was measured at the same time, thereby considerably increasing the performance of the device. The frontend electronics buffers the generator output and applies a potentiostatic signal to the common electrode of the chip. The applied voltage is monitored using the current monitor of the S-1260 via voltage/current conversion. The frontend monitors the current through the electrodes and converts it to a voltage fed into the voltage monitors of the S-1260. For assessment of the 8 electrode pairs featured by the chip, a relay-based multiplexer was implemented. Extensive characterization and calibration of the frontend were carried out in a frequency range between 100 Hz and 1 MHz. Investigating the influence of the multiplexer and the frontend electronics, direct measurement with and without frontend was compared. Although differences were evident, they have been negligible below one per cent. The significance of measurement using the complex S-1260-frontend-electrode was tested using Kohlrausch's law. The impedance of an electrolytic dilution series was measured and compared to the theoretical values. The coincidence of measured values and theoretical prediction serves as an indicator for electrode sensitivity to cell behavior. Monitoring of cell behavior on the microelectrode surface will be shown as an example.

SELECTION OF CITATIONS
SEARCH DETAIL
...