Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters











Publication year range
1.
Pract Lab Med ; 18: e00141, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31720353

ABSTRACT

BACKGROUND: Decreased galactocerebrosidase (GALC) enzyme activity is causative for Krabbe disease, a lysosomal storage disorder with devastating neurodegenerative consequences. Quantitative fluorimetric assays for GALC activity in isolated blood and skin cells have been described; however, no such assay has been described using dried blood spot (DBS) specimens. METHODS: GALC enzyme activity was measured quantitatively using fluorescence from a novel glycosidic substrate: carboxy derived from 6-hexadecanoylamino-4-methylumbelliferone. GALC activity was demonstrated on newborn DBS specimens, known Krabbe disease patient specimens, proficiency testing and quality control samples. RESULTS: We present data on characterization of the novel substrate and assay, including pH optimization and enzyme kinetics using a fluorimetric profile. Single and multi-day precision analyses revealed tight analytical measurements with %CV ranging from 5.2% to 14.1%. GALC enzyme activity was linear over the range of 0.31 - 12.04 µmol/l/h with a limit of detection of 0.066 µmol/l/h. Our results with this assay show a clear discrimination between GALC activities in samples from Krabbe disease patients versus presumed normal newborn samples. CONCLUSIONS: A fluorimetric assay for GALC enzyme activity measurement on dried blood spot specimens is feasible. Improvements to the assay including novel substrate design, increased substrate concentration and removal of sodium chloride maximize the specificity of the assay and minimize interference from ß-galactosidase.

2.
Mol Genet Metab ; 105(3): 519-21, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22227323

ABSTRACT

Mucopolysaccharidosis type II (MPS II) or Hunter syndrome is a lysosomal storage disease caused by deficiency of iduronate-2-sulfatase (IDS). A convenient single-step fluorometric microplate enzyme assay has been developed and validated for clinical diagnosis of MPS II using dried blood spots (DBS). The assay compared well with a recently reported digital microfluidic method, from which it was adapted. Results show that this DBS assay is robust and reproducible using both technologies.


Subject(s)
Dried Blood Spot Testing , Enzyme Assays/methods , Iduronate Sulfatase/blood , Mucopolysaccharidosis II/diagnosis , Fluorometry/methods , Humans , Iduronate Sulfatase/genetics , Microfluidic Analytical Techniques , Mucopolysaccharidosis II/blood , Mucopolysaccharidosis II/enzymology
3.
Anal Chem ; 83(22): 8439-47, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-21932784

ABSTRACT

The feasibility of implementing pyrosequencing chemistry within droplets using electrowetting-based digital microfluidics is reported. An array of electrodes patterned on a printed-circuit board was used to control the formation, transportation, merging, mixing, and splitting of submicroliter-sized droplets contained within an oil-filled chamber. A three-enzyme pyrosequencing protocol was implemented in which individual droplets contained enzymes, deoxyribonucleotide triphosphates (dNTPs), and DNA templates. The DNA templates were anchored to magnetic beads which enabled them to be thoroughly washed between nucleotide additions. Reagents and protocols were optimized to maximize signal over background, linearity of response, cycle efficiency, and wash efficiency. As an initial demonstration of feasibility, a portion of a 229 bp Candida parapsilosis template was sequenced using both a de novo protocol and a resequencing protocol. The resequencing protocol generated over 60 bp of sequence with 100% sequence accuracy based on raw pyrogram levels. Excellent linearity was observed for all of the homopolymers (two, three, or four nucleotides) contained in the C. parapsilosis sequence. With improvements in microfluidic design it is expected that longer reads, higher throughput, and improved process integration (i.e., "sample-to-sequence" capability) could eventually be achieved using this low-cost platform.


Subject(s)
DNA, Fungal/analysis , DNA, Fungal/genetics , Microfluidic Analytical Techniques/methods , Sequence Analysis, DNA/methods , Base Sequence , Candida/genetics , Deoxyribonucleotides/analysis , Deoxyribonucleotides/genetics , Deoxyribonucleotides/metabolism , Electrodes , Enzymes/chemistry , Enzymes/metabolism , Microfluidic Analytical Techniques/instrumentation , Sequence Analysis, DNA/instrumentation , Templates, Genetic
4.
Clin Chem ; 57(10): 1444-51, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21859904

ABSTRACT

BACKGROUND: Newborn screening for lysosomal storage diseases (LSDs) has been gaining considerable interest owing to the availability of enzyme replacement therapies. We present a digital microfluidic platform to perform rapid, multiplexed enzymatic analysis of acid α-glucosidase (GAA) and acid α-galactosidase to screen for Pompe and Fabry disorders. The results were compared with those obtained using standard fluorometric methods. METHODS: We performed bench-based, fluorometric enzymatic analysis on 60 deidentified newborn dried blood spots (DBSs), plus 10 Pompe-affected and 11 Fabry-affected samples, at Duke Biochemical Genetics Laboratory using a 3-mm punch for each assay and an incubation time of 20 h. We used a digital microfluidic platform to automate fluorometric enzymatic assays at Advanced Liquid Logic Inc. using extract from a single punch for both assays, with an incubation time of 6 h. Assays were also performed with an incubation time of 1 h. RESULTS: Assay results were generally comparable, although mean enzymatic activity for GAA using microfluidics was approximately 3 times higher than that obtained using bench-based methods, which could be attributed to higher substrate concentration. Clear separation was observed between the normal and affected samples at both 6- and 1-h incubation times using digital microfluidics. CONCLUSIONS: A digital microfluidic platform compared favorably with a clinical reference laboratory to perform enzymatic analysis in DBSs for Pompe and Fabry disorders. This platform presents a new technology for a newborn screening laboratory to screen LSDs by fully automating all the liquid-handling operations in an inexpensive system, providing rapid results.


Subject(s)
Clinical Enzyme Tests/instrumentation , Fabry Disease/diagnosis , Glycogen Storage Disease Type II/diagnosis , Lab-On-A-Chip Devices , Microfluidic Analytical Techniques/instrumentation , alpha-Galactosidase/blood , alpha-Glucosidases/blood , Fluorometry , Humans , Infant, Newborn , Neonatal Screening
6.
Expert Rev Mol Diagn ; 11(4): 393-407, 2011 May.
Article in English | MEDLINE | ID: mdl-21545257

ABSTRACT

Digital microfluidics based on electrowetting is a type of microfluidic platform in which liquids are processed as individual unit-sized droplets that are dispensed from a source, merged together, split apart or transported between locations on demand. These devices are implemented using arrays of surface electrodes to control the shape and position of droplets through the electrowetting effect. A major thrust of digital microfluidics research has been the development of integrated lab-on-a-chip devices to perform clinical in vitro diagnostic assays. A variety of preparatory and analytical processes have been implemented and feasibility has been demonstrated for test types ranging from clinical chemistries to immunoassays, nucleic acid tests and cell-based assays. In this article, the current state and future potential of digital microfluidics for clinical diagnostic testing is reviewed and evaluated.


Subject(s)
Clinical Laboratory Techniques , Electrowetting , Microfluidic Analytical Techniques , Humans , Specimen Handling/methods
7.
Diagn Microbiol Infect Dis ; 67(1): 22-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20227222

ABSTRACT

Rapid, accurate diagnosis of community-acquired pneumonia (CAP) due to Mycoplasma pneumoniae is compromised by low sensitivity of culture and serology. Polymerase chain reaction (PCR) has emerged as a sensitive method to detect M. pneumoniae DNA in clinical specimens. However, conventional real-time PCR is not cost-effective for routine or outpatient implementation. Here, we evaluate a novel microfluidic real-time PCR platform (Advanced Liquid Logic, Research Triangle Park, NC) that is rapid, portable, and fully automated. We enrolled patients with CAP and extracted DNA from nasopharyngeal wash (NPW) specimens using a biotinylated capture probe and streptavidin-coupled magnetic beads. Each extract was tested for M. pneumoniae-specific DNA by real-time PCR on both conventional and microfluidic platforms using Taqman probe and primers. Three of 59 (5.0%) NPWs were positive, and agreement between the methods was 98%. The microfluidic platform was equally sensitive but 3 times faster and offers an inexpensive and convenient diagnostic test for microbial DNA.


Subject(s)
Bacteriological Techniques/methods , Microfluidics/methods , Molecular Diagnostic Techniques/methods , Mycoplasma pneumoniae/isolation & purification , Pneumonia, Mycoplasma/diagnosis , Polymerase Chain Reaction/methods , Automation , Community-Acquired Infections/microbiology , Humans , Mycoplasma pneumoniae/genetics , Nasopharynx/microbiology , Pneumonia, Mycoplasma/microbiology , Point-of-Care Systems , Sensitivity and Specificity , Time Factors
8.
Anal Chem ; 82(6): 2310-6, 2010 Mar 15.
Article in English | MEDLINE | ID: mdl-20151681

ABSTRACT

This paper details the development of a digital microfluidic platform for multiplexed real-time polymerase chain reactions (PCR). Liquid samples in discrete droplet format are programmably manipulated upon an electrode array by the use of electrowetting. Rapid PCR thermocycling is performed in a closed-loop flow-through format where for each cycle the reaction droplets are cyclically transported between different temperature zones within an oil-filled cartridge. The cartridge is fabricated using low-cost printed-circuit-board technology and is intended to be a single-use disposable device. The PCR system exhibited remarkable amplification efficiency of 94.7%. To test its potential application in infectious diseases, this novel PCR system reliably detected diagnostic DNA levels of methicillin-resistant Staphylococcus aureus (MRSA), Mycoplasma pneumoniae , and Candida albicans . Amplification of genomic DNA samples was consistently repeatable across multiple PCR loops both within and between cartridges. In addition, simultaneous real-time PCR amplification of both multiple different samples and multiple different targets on a single cartridge was demonstrated. A novel method of PCR speed optimization using variable cycle times has also been proposed and proven feasible. The versatile system includes magnetic bead handling capability, which was applied to the analysis of simulated clinical samples that were prepared from whole blood using a magnetic bead capture protocol. Other salient features of this versatile digital microfluidic PCR system are also discussed, including the configurability and scalability of microfluidic operations, instrument portability, and substrate-level integration with other pre- and post-PCR processes.


Subject(s)
DNA, Bacterial/analysis , DNA, Fungal/analysis , Methicillin-Resistant Staphylococcus aureus/genetics , Microfluidics/instrumentation , Polymerase Chain Reaction/instrumentation , Candida albicans/genetics , DNA, Bacterial/genetics , DNA, Fungal/genetics , Equipment Design , Mycoplasma pneumoniae/genetics
9.
Lab Chip ; 8(12): 2188-96, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19023486

ABSTRACT

A digital microfluidic platform for performing heterogeneous sandwich immunoassays based on efficient handling of magnetic beads is presented in this paper. This approach is based on manipulation of discrete droplets of samples and reagents using electrowetting without the need for channels where the droplets are free to move laterally. Droplet-based manipulation of magnetic beads therefore does not suffer from clogging of channels. Immunoassays on a digital microfluidic platform require the following basic operations: bead attraction, bead washing, bead retention, and bead resuspension. Several parameters such as magnetic field strength, pull force, position, and buffer composition were studied for effective bead operations. Dilution-based washing of magnetic beads was demonstrated by immobilizing the magnetic beads using a permanent magnet and splitting the excess supernatant using electrowetting. Almost 100% bead retention was achieved after 7776-fold dilution-based washing of the supernatant. Efficient resuspension of magnetic beads was achieved by transporting a droplet with magnetic beads across five electrodes on the platform and exploiting the flow patterns within the droplet to resuspend the beads. All the magnetic-bead droplet operations were integrated together to generate standard curves for sandwich heterogeneous immunoassays on human insulin and interleukin-6 (IL-6) with a total time to result of 7 min for each assay.


Subject(s)
Immunoassay , Magnetics , Microfluidics/instrumentation , Microfluidics/methods , Humans , Immunoassay/methods , Insulin/chemistry , Interleukin-6/chemistry , Magnetics/instrumentation
10.
J Biol Chem ; 281(16): 10856-64, 2006 Apr 21.
Article in English | MEDLINE | ID: mdl-16492667

ABSTRACT

Parathyroid hormone (PTH) regulates calcium homeostasis via the type I PTH/PTH-related peptide (PTH/PTHrP) receptor (PTH1R). The purpose of the present study was to identify the contributions of distinct signaling mechanisms to PTH-stimulated activation of the mitogen-activated protein kinases (MAPK) ERK1/2. In Human embryonic kidney 293 (HEK293) cells transiently transfected with hPTH1R, PTH stimulated a robust increase in ERK activity. The time course of ERK1/2 activation was biphasic with an early peak at 10 min and a later sustained ERK1/2 activation persisting for greater than 60 min. Pretreatment of HEK293 cells with the PKA inhibitor H89 or the PKC inhibitor GF109203X, individually or in combination reduced the early component of PTH-stimulated ERK activity. However, these inhibitors of second messenger dependent kinases had little effect on the later phase of PTH-stimulated ERK1/2 phosphorylation. This later phase of ERK1/2 activation at 30-60 min was blocked by depletion of cellular beta-arrestin 2 and beta-arrestin 1 by small interfering RNA. Furthermore, stimulation of hPTH1R with PTH analogues, [Trp1]PTHrp-(1-36) and [d-Trp12,Tyr34]PTH-(7-34), selectively activated G(s)/PKA-mediated ERK1/2 activation or G protein-independent/beta-arrestin-dependent ERK1/2 activation, respectively. It is concluded that PTH stimulates ERK1/2 through several distinct signal transduction pathways: an early G protein-dependent pathway meditated by PKA and PKC and a late pathway independent of G proteins mediated through beta-arrestins. These findings imply the existence of distinct active conformations of the hPTH1R responsible for the two pathways, which can be stimulated by unique ligands. Such ligands may have distinct and valuable therapeutic properties.


Subject(s)
Arrestins/physiology , GTP-Binding Proteins/physiology , Mitogen-Activated Protein Kinase 1/metabolism , Mitogen-Activated Protein Kinase 3/metabolism , Receptor, Parathyroid Hormone, Type 1/metabolism , Arrestins/metabolism , Cell Line , Cells, Cultured , Culture Media, Serum-Free/pharmacology , Cyclic AMP/metabolism , Cyclic AMP-Dependent Protein Kinases/metabolism , DNA/metabolism , DNA, Complementary/metabolism , GTP-Binding Proteins/metabolism , Humans , Immunoblotting , Immunoprecipitation , Indoles/pharmacology , Isoquinolines/pharmacology , Ligands , MAP Kinase Signaling System , Maleimides/pharmacology , Mutation , Phosphorylation , Protein Kinases/metabolism , RNA, Small Interfering/metabolism , Receptor, Parathyroid Hormone, Type 1/genetics , Signal Transduction , Sulfonamides/pharmacology , Time Factors , Transfection , beta-Arrestin 1 , beta-Arrestin 2 , beta-Arrestins
SELECTION OF CITATIONS
SEARCH DETAIL