Health Phys ; 115(4): 474-489, 2018 10.
Article in English | MEDLINE | ID: mdl-30148813

ABSTRACT

A regulatory authority for radiation safety should continuously evaluate and improve the national safety framework, in line with current requirements and standards. In this context, the Greek Atomic Energy Commission initiated a series of concerted actions. The radiation dose to the population due to public and medical exposures was assessed. The assessment of dose due to public exposure was based on measurements of radon concentrations in dwellings, radionuclide concentrations in environmental samples, and air dose rates; the assessment of dose due to medical exposure was based on dose measurements for typical examinations or procedures and data on their frequency. The mean effective dose to a member of the population was found to be 4.5 mSv (1.8 mSv and 2.7 mSv from medical and public exposures, respectively). Regarding occupational exposure, aircrew dose assessment, eye lens monitoring, and the national dose registry were significantly improved. With respect to artificial tanning (sun beds), the ultraviolet radiation produced was assessed and the practices followed were observed. Results demonstrated exceedance of the 0.3 W m erythema effective irradiance limit set in European Union standards by 63.5% of the sun beds measured, along with general noncompliance with standards. An overarching activity was the upgrade of the Greek Atomic Energy Commission information system in order to collect and disseminate radiation data electronically, launch a networking strategy for interaction with stakeholders, and facilitate the process of regulatory control. In response to the above findings, regulatory actions have been initiated.


Subject(s)
Occupational Exposure/analysis , Radiation Monitoring/methods , Radiation Protection/methods , Radiation Protection/standards , Sunbathing , Construction Materials , Drinking Water , Greece , Humans , Lens, Crystalline/radiation effects , Radiation Dosage , Radioisotopes , Radon/analysis , Surveys and Questionnaires , Ultraviolet Rays , Water Pollutants, Radioactive
2.
Radiat Prot Dosimetry ; 163(3): 319-24, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24891405

ABSTRACT

The purpose of this study is to present a national survey that was performed in Greece for the establishment of national Dose Reference Levels (DRLs) for seven common adult Computed Tomography (CT) examinations. Volumetric computed tomography dose index and dose-length product values were collected from the post-data page of 65 'modern' systems that incorporate tube current modulation. Moreover, phantom dose measurements on 26 'older' systems were performed. Finally, the effective dose to the patient from a typical acquisition during these examinations was estimated. The suggested national DRLs are generally comparable with respective published values from similar European studies, with the exception of sinuses CT, which presents significantly higher values. This fact, along with the large variation of the systems' dose values that were observed even for scanners of the same type, indicates a need for further patient protection optimisation without compromising the clinical outcome.


Subject(s)
Cone-Beam Computed Tomography/statistics & numerical data , Cone-Beam Computed Tomography/standards , Environmental Exposure/analysis , Environmental Exposure/standards , Whole-Body Counting/statistics & numerical data , Whole-Body Counting/standards , Adult , Body Burden , Cone-Beam Computed Tomography/instrumentation , Equipment Design , Equipment Failure Analysis/standards , Greece , Guidelines as Topic , Humans , Male , Phantoms, Imaging/standards , Radiation Dosage , Radiation Protection/standards , Radiation Protection/statistics & numerical data , Reference Values
3.
Radiat Prot Dosimetry ; 147(1-2): 202-5, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21821614

ABSTRACT

The purpose of this study is to evaluate and compare the performance of 52 full field digital (FFD) and computed radiography (CR) mammography systems checked by the Greek Atomic Energy Commission with respect to dose and image quality. Entrance surface air kerma (ESAK) was measured and average glandular dose (AGD) was calculated according to the European protocol on dosimetry in mammography. The exposures were performed using the clinical protocol of each laboratory. The image quality was assessed by the total score of resolved phantom structures incorporated in an American College of Radiology accreditation phantom. The mean ESAK values for FFD and CR systems were 4.59 ± 1.93 and 5.0 ± 1.78 mGy, respectively, whereas the AGD yielded a mean value of 1.06 ± 0.36 mGy for the FFD and 1.04 ± 0.35 mGy for the CR systems. Considering image quality, FFD systems indicated a mean total score of 13.04 ± 0.89, whereas CR systems a mean total score of 11.54 ± 1.06.


Subject(s)
Breast/radiation effects , Mammography , Radiographic Image Enhancement , Tomography, X-Ray Computed , Breast/pathology , Female , Greece , Humans , Phantoms, Imaging , Radiation Dosage
4.
Radiat Prot Dosimetry ; 147(1-2): 129-32, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21743078

ABSTRACT

The purpose of this study is to evaluate image quality of various computed tomography (CT) scanners installed in Greece, as well as to investigate patient doses from common CT examinations. An image quality survey was performed in 44 CT scanners countrywide. The imaging performance of the systems was evaluated by measurements of certain parameters, such as image noise, spatial uniformity, high- and low-contrast resolution and slice thickness accuracy. Moreover, preliminary results of patient dose survey are presented. Concerning image quality, 80 % of the scanners were found to be in compliance with the national legislation and relative international guidelines for all the examined parameters. Weighted CT dose index and dose-length product values for chest and abdomen routine examinations were generally below the dose reference levels (DRLs) suggested by the European Commission. However, some scanners were found to deliver significantly higher doses than the suggested DRL for head routine examinations. Finally, differences in the performance among scanners of the same type and similar age were observed, pointing out the importance of frequent calibration, routine quality control and proper maintenance.


Subject(s)
Image Processing, Computer-Assisted/instrumentation , Radiation Dosage , Radiation Protection/statistics & numerical data , Radiation Protection/standards , Tomography Scanners, X-Ray Computed/standards , Greece , Humans , Quality Control , Reference Values
5.
Radiat Prot Dosimetry ; 129(4): 419-25, 2008.
Article in English | MEDLINE | ID: mdl-17971345

ABSTRACT

This study presents the results from a survey conducted by the Greek Atomic Energy Commission (GAEC), during the period 1998-2003, in 530 public and private owned fluoroscopic X-ray systems in Greece. Certain operational parameters for conventional and remote control systems were assessed, according to a quality control protocol developed by GAEC on the basis of the current literature. Public (91.5%) and private (81.5%) owned fluoroscopic units exhibit high-contrast resolution values over 1 lp mm(-1). Moreover, 88.5 and 87.1% of the fluoroscopic units installed in the public and private sector, respectively, present Maximum Patient Entrance Kerma Rate values lower than 100 mGy min(-1). Additionally, 68.3% of the units assessed were found to perform within the acceptance limits. Finally, the third quartile of the Entrance Surface Dose Rate distribution was estimated according to the Dose Reference Level definition and found equal to 35 mGy min(-1).


Subject(s)
Fluoroscopy/methods , Fluoroscopy/standards , Radiation Dosage , Greece , Humans , Private Sector , Public Sector , Quality Control , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Radiographic Image Interpretation, Computer-Assisted/methods
6.
Phys Med ; 23(3-4): 107-14, 2007 Dec.
Article in English | MEDLINE | ID: mdl-18023226

ABSTRACT

This study presents the results of the on-site inspections performed by the Greek Atomic Energy Commission (GAEC) on conventional X-ray systems, both in public and private medical radiology departments. A part of the inspection concerns the assessment of important radiographic parameters obtained according to a specified quality control protocol and the comparison of the measured parameter values with the corresponding acceptance limits. A total number of 1011 radiographic systems were inspected by the GAEC during the period 1998-2004, with 63.4% of them being privately owned. Analysis of 8 different operational parameters is carried out providing information on the overall performance, as well as on each parameter of the inspected X-ray systems. Tube voltage reproducibility values show the highest percentage of acceptability (98.9%, 99.5% for private and public owned radiographic systems respectively), while linearity of radiation output for private systems (72.5%) and time accuracy for public ones (72.7%) show the worst results. The comparison of the results for the private sector to those of a similar study carried out during the period 1995-1997 indicates a substantial improvement in X-ray systems performance. Higher level of improvement shows exposure time accuracy (12.2% percentile increase) and linearity of radiation output (12.5% percentile increase). Nevertheless, the situation can be further optimized if maintenance and quality control of the radiographic systems are carried out on a more regular basis.


Subject(s)
Radiography/methods , Radiography/standards , Advisory Committees/legislation & jurisprudence , Greece , Humans , Private Sector , Public Sector , Reproducibility of Results , Sensitivity and Specificity , Time Factors
7.
Radiat Prot Dosimetry ; 118(3): 260-4, 2006.
Article in English | MEDLINE | ID: mdl-16143723

ABSTRACT

More than 40 industrial radiography laboratories are operating in Greece using X-ray or gamma-ray sources and more than 250 workers occupationally exposed to ionising radiation in these facilities are monitored on a regular basis. This study presents the evolution of individual doses received by radiographers during the past years. The mean annual dose (MAD) of all workers as well as of exposed workers is estimated, and correlated to the types of laboratories and practices applied. The MAD of the exposed workers in industrial radiography is compared with the doses of workers in other specialties and with the doses of radiographers in other countries. Furthermore, the study attempts to propose dose constraints for the practices in industrial radiography, according to the BSS European directive and the relevant Greek radiation protection legislation. The proposed value was defined as the dose below which the annual doses of 75% of the exposed radiographers are expected to be included.


Subject(s)
Industry/statistics & numerical data , Laboratories/statistics & numerical data , Occupational Exposure/analysis , Occupational Exposure/statistics & numerical data , Radiation Monitoring/methods , Radiography/statistics & numerical data , Risk Assessment/methods , Gamma Rays , Greece/epidemiology , Humans , Materials Testing/statistics & numerical data , Risk Factors , X-Rays
8.
Neuropsychologia ; 33(3): 385-90, 1995 Mar.
Article in English | MEDLINE | ID: mdl-7792006

ABSTRACT

The measurement of autonomic nervous system (ANS) activity was performed on 10 male and five female sharp shooters (rifle) during competitions. Electrodermal, thermovascular, cardiorespiratory variables and two indices of performance were recorded simultaneously. When the subjects fired shots that hit the target, they had a higher number of negative skin potential responses than when they missed. The responses had lower amplitude but lasted longer than when the shots missed the target. Good performance seemed to depend on high levels of motivation (increase in negative potential response), better mastery of the emotional reactivity (low amplitude response), and greater concentration time (increased duration of response).


Subject(s)
Autonomic Nervous System/physiology , Firearms , Sports , Competitive Behavior , Emotions , Female , Heart Rate , Humans , Male , Respiration , Skin/blood supply , Skin Tests , Task Performance and Analysis
9.
Article in English | MEDLINE | ID: mdl-8223539

ABSTRACT

Four autonomic nervous system (ANS) variables: skin potential and resistance, skin blood flow and temperature - plus instantaneous heart rate and respiratory frequency - were simultaneously recorded during sporting competitions. The performances of 15 marksmen and 7 archers were analysed by comparing the variations in the six parameters during a concentration phase prior to shooting and during the shooting (or active) phase proper. The results of the performances distinguished two groups of sportsmen: firstly, the best shots and secondly, the worst shots. Comparison of the autonomic responses between the groups showed statistically significant correlations among the ANS variables. This made possible a relationship between performance characteristics and a percepto-effector factor to be defined. More precisely, this factor was defined as the number of correlations of the measured variables in the two phases, concentration and shooting. A positive relationship was demonstrated--the higher the factor, the better the performance. In addition, the stability of the factor was greater within the best marksmen and archers group. A model of the temporal change of the percepto-effector factor in both groups was given in three dimensions. This modelling of performance characteristics gave a visual indication of the differences between best/worst performances.


Subject(s)
Autonomic Nervous System/physiology , Models, Neurological , Physical Exertion , Sports , Female , Galvanic Skin Response , Heart Rate , Humans , Male , Regional Blood Flow , Respiration , Skin/blood supply , Skin Temperature