Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Epilepsia ; 62(2): 416-425, 2021 02.
Article in English | MEDLINE | ID: mdl-33507573

ABSTRACT

OBJECTIVE: Video-electroencephalography (vEEG) is an important component of epilepsy diagnosis and management. Nevertheless, inpatient vEEG monitoring fails to capture seizures in up to one third of patients. We hypothesized that personalized seizure forecasts could be used to optimize the timing of vEEG. METHODS: We used a database of ambulatory vEEG studies to select a cohort with linked electronic seizure diaries of more than 20 reported seizures over at least 8 weeks. The total cohort included 48 participants. Diary seizure times were used to detect individuals' multiday seizure cycles and estimate times of high seizure risk. We compared whether estimated seizure risk was significantly different between conclusive and inconclusive vEEGs, and between vEEG with and without recorded epileptic activity. vEEGs were conducted prior to self-reported seizures; hence, the study aimed to provide a retrospective proof of concept that cycles of seizure risk were correlated with vEEG outcomes. RESULTS: Estimated seizure risk was significantly higher for conclusive vEEGs and vEEGs with epileptic activity. Across all cycle strengths, the average time in high risk during vEEG was 29.1% compared with 14% for the conclusive/inconclusive groups and 32% compared to 18% for the epileptic activity/no epileptic activity groups. On average, 62.5% of the cohort showed increased time in high risk during their previous vEEG when epileptic activity was recorded (compared to 28% of the cohort where epileptic activity was not recorded). For conclusive vEEGs, 50% of the cohort had increased time in high risk, compared to 21.5% for inconclusive vEEGs. SIGNIFICANCE: Although retrospective, this study provides a proof of principle that scheduling monitoring times based on personalized seizure risk forecasts can improve the yield of vEEG. Forecasts can be developed at low cost from mobile seizure diaries. A simple scheduling tool to improve diagnostic outcomes may reduce cost and risks associated with delayed or missed diagnosis in epilepsy.


Subject(s)
Electroencephalography , Epilepsy/physiopathology , Seizures/physiopathology , Self Report , Adolescent , Adult , Aged , Child , Epilepsy/diagnosis , Female , Forecasting , Humans , Male , Middle Aged , Proof of Concept Study , Retrospective Studies , Seizures/diagnosis , Video Recording , Young Adult
4.
Brain ; 142(3): 633-646, 2019 03 01.
Article in English | MEDLINE | ID: mdl-30715195

ABSTRACT

Spinal cord lesions detected on MRI hold important diagnostic and prognostic value for multiple sclerosis. Previous attempts to correlate lesion burden with clinical status have had limited success, however, suggesting that lesion location may be a contributor. Our aim was to explore the spatial distribution of multiple sclerosis lesions in the cervical spinal cord, with respect to clinical status. We included 642 suspected or confirmed multiple sclerosis patients (31 clinically isolated syndrome, and 416 relapsing-remitting, 84 secondary progressive, and 73 primary progressive multiple sclerosis) from 13 clinical sites. Cervical spine lesions were manually delineated on T2- and T2*-weighted axial and sagittal MRI scans acquired at 3 or 7 T. With an automatic publicly-available analysis pipeline we produced voxelwise lesion frequency maps to identify predilection sites in various patient groups characterized by clinical subtype, Expanded Disability Status Scale score and disease duration. We also measured absolute and normalized lesion volumes in several regions of interest using an atlas-based approach, and evaluated differences within and between groups. The lateral funiculi were more frequently affected by lesions in progressive subtypes than in relapsing in voxelwise analysis (P < 0.001), which was further confirmed by absolute and normalized lesion volumes (P < 0.01). The central cord area was more often affected by lesions in primary progressive than relapse-remitting patients (P < 0.001). Between white and grey matter, the absolute lesion volume in the white matter was greater than in the grey matter in all phenotypes (P < 0.001); however when normalizing by each region, normalized lesion volumes were comparable between white and grey matter in primary progressive patients. Lesions appearing in the lateral funiculi and central cord area were significantly correlated with Expanded Disability Status Scale score (P < 0.001). High lesion frequencies were observed in patients with a more aggressive disease course, rather than long disease duration. Lesions located in the lateral funiculi and central cord area of the cervical spine may influence clinical status in multiple sclerosis. This work shows the added value of cervical spine lesions, and provides an avenue for evaluating the distribution of spinal cord lesions in various patient groups.


Subject(s)
Cervical Cord/pathology , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology , Adult , Brain/pathology , Cervical Cord/diagnostic imaging , Cervical Cord/metabolism , Disability Evaluation , Disease Progression , Female , Gray Matter/pathology , Humans , Magnetic Resonance Imaging/methods , Male , Middle Aged , Multiple Sclerosis, Chronic Progressive/pathology , Multiple Sclerosis, Relapsing-Remitting/pathology , Spatial Analysis , Spinal Cord/pathology , Spinal Cord Diseases , White Matter/pathology
5.
Neuroimage ; 184: 901-915, 2019 01 01.
Article in English | MEDLINE | ID: mdl-30300751

ABSTRACT

The spinal cord is frequently affected by atrophy and/or lesions in multiple sclerosis (MS) patients. Segmentation of the spinal cord and lesions from MRI data provides measures of damage, which are key criteria for the diagnosis, prognosis, and longitudinal monitoring in MS. Automating this operation eliminates inter-rater variability and increases the efficiency of large-throughput analysis pipelines. Robust and reliable segmentation across multi-site spinal cord data is challenging because of the large variability related to acquisition parameters and image artifacts. In particular, a precise delineation of lesions is hindered by a broad heterogeneity of lesion contrast, size, location, and shape. The goal of this study was to develop a fully-automatic framework - robust to variability in both image parameters and clinical condition - for segmentation of the spinal cord and intramedullary MS lesions from conventional MRI data of MS and non-MS cases. Scans of 1042 subjects (459 healthy controls, 471 MS patients, and 112 with other spinal pathologies) were included in this multi-site study (n = 30). Data spanned three contrasts (T1-, T2-, and T2∗-weighted) for a total of 1943 vol and featured large heterogeneity in terms of resolution, orientation, coverage, and clinical conditions. The proposed cord and lesion automatic segmentation approach is based on a sequence of two Convolutional Neural Networks (CNNs). To deal with the very small proportion of spinal cord and/or lesion voxels compared to the rest of the volume, a first CNN with 2D dilated convolutions detects the spinal cord centerline, followed by a second CNN with 3D convolutions that segments the spinal cord and/or lesions. CNNs were trained independently with the Dice loss. When compared against manual segmentation, our CNN-based approach showed a median Dice of 95% vs. 88% for PropSeg (p ≤ 0.05), a state-of-the-art spinal cord segmentation method. Regarding lesion segmentation on MS data, our framework provided a Dice of 60%, a relative volume difference of -15%, and a lesion-wise detection sensitivity and precision of 83% and 77%, respectively. In this study, we introduce a robust method to segment the spinal cord and intramedullary MS lesions on a variety of MRI contrasts. The proposed framework is open-source and readily available in the Spinal Cord Toolbox.


Subject(s)
Image Processing, Computer-Assisted/methods , Multiple Sclerosis/diagnostic imaging , Multiple Sclerosis/pathology , Neural Networks, Computer , Spinal Cord/pathology , Humans , Magnetic Resonance Imaging/methods , Observer Variation , Pattern Recognition, Automated , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...