Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Eur J Radiol ; 120: 108646, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31526892

ABSTRACT

PURPOSE: Appropriate lung nodule management is essential to minimizing unnecessary patient recall in lung cancer screening. Two European guidelines provide differing recommendations in that participants with nodules ≥100 mm3 or ≥80 mm3 respectively should be recalled, at baseline. Nodule size estimation is known to vary between volumetry software packages (VSPs). The aim of this study was to examine the impact of choice of VSP on participant recall rates, when applying different European nodule management guidelines. An additional aim was to compare recall rates between 7 VSPs and manual diameter measurements. METHODS: 156 small-sized lung nodules (50-150 mm3) from the UK Lung Screening trial were measured using 7 different VSPs (VSP1-7) and also using manual diameter. The type of VSP used in the NELSON study (VSP1), on which European nodule management guidelines are based, provided the reference standard. Nodule size was compared using Bland Altman, and recall rates by Mcnemar's test. RESULTS: Compared to the reference standard, a 100 mm3 threshold for recall, resulted in no difference in recall rates only for VSP 5 & 7. Using an 80mm3 threshold resulted in no difference in recall rates for VSP2 & 6. Recall rates were significantly higher for VSP 4 regardless of threshold and when using manual diameter measurements. CONCLUSIONS: Appropriate nodule size thresholds for recall in screening depend on the type of volumetry software used. The results highlight the importance of benchmarking of volumetry packages.


Subject(s)
Early Detection of Cancer/methods , Lung Neoplasms/pathology , Clinical Decision-Making , Humans , Lung/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/prevention & control , Software , Solitary Pulmonary Nodule/diagnostic imaging , Solitary Pulmonary Nodule/pathology , Tomography, X-Ray Computed/methods , Tumor Burden
2.
Clin Radiol ; 72(5): 343-355, 2017 May.
Article in English | MEDLINE | ID: mdl-28118995

ABSTRACT

Idiopathic pulmonary fibrosis (IPF) is the most common idiopathic interstitial pneumonia and is increasingly recognised. Prior to the advent of effective therapies, achieving an early diagnosis was arguably of little prognostic consequence given IPF was considered an untreatable and uniformly fatal disease. The advent of new drug treatments has given hope for the future and raised the profile of IPF. International management guidelines highlight the critical role of radiology as part of an interstitial lung disease multidisciplinary team approach in reaching an accurate and early diagnosis of IPF. The diagnostic criteria and levels of diagnostic confidence for the radio-pathological pattern associated with the clinical syndrome of IPF, usual interstitial pneumonia (UIP), appear seemingly straightforward; however, with increasing research and recognition of radiopathological interobserver variability, limitations of this classification model are becoming increasingly apparent. This review describes ancillary radiological features, comorbidities, and emerging new entities that potentially co-exist with IPF. Beyond diagnosis radiology is developing as a key prognostic tool to inform longitudinal patient evaluation. These diagnostic and prognostic clinical challenges and the future role of radiology in IPF are discussed.


Subject(s)
Idiopathic Pulmonary Fibrosis/diagnostic imaging , Idiopathic Pulmonary Fibrosis/drug therapy , Tomography, X-Ray Computed/methods , Humans , Lung/diagnostic imaging , Tomography, X-Ray Computed/trends
3.
J R Coll Physicians Edinb ; 45(3): 213-4, 2015.
Article in English | MEDLINE | ID: mdl-26517101

ABSTRACT

Organising pneumonia is one of the responses of the lung to injury and can mimic bacterial pneumonia but importantly it does not respond to antibiotic therapy. We present the case of a 67-year-old male who was diagnosed with organising pneumonia secondary to dronedarone. Drug reactions are a common cause and early identification of the culprit is mandatory to prevent further morbidity and ensure a favourable outcome. On chest radiography there may be fleeting peripheral consolidation, while computed tomography can show a range of stereotyped patterns including perilobular consolidation. Bronchoscopic biopsy may not always be possible but response to steroids is often rapid following removal of the culprit drug. Dronedarone should be included in the list of possible drugs and the Pneumotox database remains a useful resource for the clinician when acute drug-related pneumotoxicity is suspected.


Subject(s)
Amiodarone/analogs & derivatives , Lung/drug effects , Pneumonia/chemically induced , Aged , Amiodarone/adverse effects , Dronedarone , Humans , Male , Pneumonia/diagnostic imaging
6.
Clin Radiol ; 64(9): 872-84, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19664477

ABSTRACT

The widespread use of multidetector computed tomography for imaging of the chest has lead to a significant increase in the number of incidentally detected pulmonary nodules. The significance of these nodules is often uncertain and further investigations may be required. This article will review the spectrum of imaging appearances of small pulmonary nodules, and highlight the few features that allow confident characterization of a nodule as benign or malignant; current guidelines for the management of incidentally detected nodules will also be discussed.


Subject(s)
Adenocarcinoma, Bronchiolo-Alveolar/diagnostic imaging , Lung Neoplasms/diagnostic imaging , Multiple Pulmonary Nodules/diagnostic imaging , Tomography, X-Ray Computed/methods , Adenocarcinoma, Bronchiolo-Alveolar/pathology , Calcinosis/diagnostic imaging , Diagnosis, Differential , Hamartoma/diagnostic imaging , Humans , Incidental Findings , Lung , Lung Neoplasms/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Middle Aged , Multiple Pulmonary Nodules/epidemiology , Multiple Pulmonary Nodules/pathology , Practice Guidelines as Topic , Radiation Dosage , Reproducibility of Results , Risk Factors , Time Factors
7.
Br J Radiol ; 82(979): 529-31, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19541944

ABSTRACT

Lung cancer is the most common cause of cancer-related death in the UK. Despite aggressive primary prevention measures and improved medical care, the 5-year survival rate is less than 10% for patients in the UK who present with symptoms. The possibility of CT screening for lung cancer provides some hope of reducing mortality. However, the case for screening remains unproven. This article explores the issues surrounding lung cancer screening in the context of historical studies, trials in progress and tentative plans for a UK CT lung cancer screening trial.


Subject(s)
Lung Neoplasms/diagnostic imaging , Tomography, X-Ray Computed , Clinical Trials as Topic , Early Detection of Cancer , Humans , Lung Neoplasms/mortality , Lung Neoplasms/prevention & control , Mass Screening , Risk Factors , United Kingdom/epidemiology
8.
Clin Radiol ; 63(10): 1112-20, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18774358

ABSTRACT

AIM: To determine whether delayed-phase liver imaging using a destructive imaging mode is able to provide similar information to phase-inversion imaging regarding detection and conspicuity of liver metastases. MATERIAL AND METHODS: Patients with a known primary malignancy with suspected liver metastases were recruited. Ultrasound was performed at baseline, and up to 5 min after the administration of Sonazoid, using phase-inversion imaging at both low and high mechanical indices (MI) and at 10-15 min using destructive imaging. One of four doses of Sonazoid was used: 0.008, 0.08, 0.12, and 0.36 microl/kg of body weight. Two observers documented lesion number and conspicuity subjectively, and divided the patients into group A (no lesions), group B (one to seven lesions), and group C(I-III) (more than eight lesions, subdivided with increasing lesion number) depending on the number of lesions and categories I-IV based on lesion conspicuity. These parameters were compared with contrast-enhanced computed tomography (CECT) as the reference standard. RESULTS: Sixteen patients were examined (six women, 10 men), mean age 67.3 years (range 48-83 years). Based on CECT imaging, the division was as follows: group A n=1, group B n=8, group C(I)n=1, group C(II)n=4, group C(III)n=2. The accuracy of baseline ultrasound versus CECT was 75% (in 12 of the 16 patients the group concurred) and the accuracy for contrast-enhanced ultrasound (CEUS) versus CECT was 93.8% (15/16). There was a significant improvement in lesion conspicuity for both low (p=0.0029) and high MI phase-inversion (p=0.0004) and destructive (p=0.0015) CEUS imaging in comparison with baseline ultrasound. Artefact was noted at higher doses of Sonazoid; and no side effects were recorded. CONCLUSION: Following a single, intravenous injection of Sonazoid, the properties of this microbubble allow for a and robust examination of the liver using two different techniques with comparable results.


Subject(s)
Ferric Compounds , Iron , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Oxides , Aged , Aged, 80 and over , Artifacts , Contrast Media/administration & dosage , Dose-Response Relationship, Drug , Female , Ferric Compounds/administration & dosage , Humans , Image Interpretation, Computer-Assisted/methods , Iron/administration & dosage , Male , Microbubbles , Middle Aged , Oxides/administration & dosage , Tomography, X-Ray Computed , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...