1.
Anal Bioanal Chem ; 403(1): 265-78, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22392371

ABSTRACT

Two multi-analyte flow-through immunoassay formats for rapid detection of mycotoxins in a variety of food matrices (peanut cake, maize, and cassava flour) were developed and evaluated. The selected food matrices are typical staple foods and export products for most low-income communities around the world. The assay formats included gel-based and membrane-based flow-through assays and were based on the principle of indirect enzyme-linked immunosorbent assay. Using the same immunoreagents, the performance characteristics of both assays were compared. To the best of our knowledge, this is the first report on such a comparison. The gel-based format was developed to screen for ochratoxin A, fumonisin B(1), deoxynivalenol, and zearalenone detection at cut-off values of 3, 1,250, 1,000, and 200 µg kg(-1), respectively, while the membrane-based format can be used to screen ochratoxin A, aflatoxin B(1,) deoxynivalenol, and zearalenone at the following cut-offs: 3, 5, 700, and 175 µg kg(-1), respectively. The applicability of these assay formats was demonstrated by evaluating the performance characteristics of both tests through performing multiple experiments on different days. Both assays were further evaluated by analyzing naturally contaminated samples in the laboratory and also in the field under tropical conditions (Cameroon, West Africa). The false-negative rate with both formats was less than 5%, which is in good agreement with Commission Decision 2002/657/EC regarding the performance of analytical methods intended for screening purposes.


Subject(s)
Food Contamination , Food Microbiology , Immunoassay/methods , Mycotoxins/analysis , Chromatography, Liquid , Enzyme-Linked Immunosorbent Assay , Limit of Detection , Tandem Mass Spectrometry
2.
J Chromatogr A ; 1218(28): 4395-405, 2011 Jul 15.
Article in English | MEDLINE | ID: mdl-21640355

ABSTRACT

The glucosinolate profile of black radish (Raphanus sativus L. niger) based dietary supplements has been investigated by HPLC-PDA, LC-ESI-MS/MS and LC-APCI-MS/MS systems. Optimization of the MS/MS parameters and LC conditions was performed using sinigrin reference standard and rapeseed certified reference material (BC190) respectively. An LC-ESI-MS/MS system was used to detect (screen) and identify the naturally occurring intact glucosinolates (GLs). The intact GLs identified were then desulfated and quantified on an HPLC-PDA system as desulfo-glucosinolates (DS-GLs). Prior to quantification, the DS-GLs were identified using an APCI-MS/MS. The HPLC-PDA method performance criteria were evaluated using glucotropaeolin potassium salt. The validated method was applied for the analysis of six dietary supplements. In total, six glucosinolates were identified and quantified in the dietary supplements; glucoraphasatin (0.2-0.48 mg/g), glucosisaustricin (0.37-0.91 mg/g), glucoraphenin (0.84-1.27 mg/g), glucoputrajivin (0.14-0.28 mg/g), glucosisymbrin (0.70-0.99 mg/g) and gluconasturtiin (0.06-0.12 mg/g). Glucoraphenin was the most abundant glucosinolate in all samples.


Subject(s)
Chromatography, High Pressure Liquid/methods , Dietary Supplements/analysis , Glucosinolates/analysis , Raphanus/chemistry , Tandem Mass Spectrometry/methods , Glucosinolates/chemistry , Hydrogen-Ion Concentration , Regression Analysis , Reproducibility of Results , Sensitivity and Specificity