Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Qual Saf Health Care ; 19(5): e35, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20511243

ABSTRACT

OBJECTIVE: To improve the clinic follow-up rate of paediatric inpatients in a tertiary care hospital. PATIENTS AND METHODS: Inpatients who received pulmonary consultations from July 2007 to June 2008 at Cincinnati Children's Hospital Medical Center were eligible for this quality-improvement project. Multiple interventions were introduced to improve follow-up in our subspecialty clinic. A χ(2) test for association was used to assess the dependence between the clinic follow-up rate and the type of care coordination intervention. We hypothesised that generalisable care coordination interventions would result in improvements. RESULTS: Two hundred and eleven patients were included. Two interventions were independently associated with improvements in the hospital follow-up rate. When a reminder to follow-up in the pulmonary clinic was inserted into the hospital discharge summary (partial intervention), the clinic follow-up rate improved from 27% to 55%. When the follow-up appointments were made for the families, with the appointments' noted in the discharge summaries, and automated appointment reminder phone calls were provided (full intervention), the follow-up rate improved further from 55% to 80%. The full intervention, when compared with no intervention, improved the clinic follow-up rate from 27% to 80%. CONCLUSION: Establishing clinic appointments for patients and providing appointment reminders increases the hospital follow-up rate for hospitalised children in outpatient clinics.


Subject(s)
Continuity of Patient Care/standards , Hospitalization , Quality Assurance, Health Care/methods , Child , Humans , Ohio , Pediatric Nursing/standards , Reminder Systems
2.
J Surg Res ; 138(1): 10-4, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17084413

ABSTRACT

BACKGROUND: Monitoring of intrapleural pressure (IPP) is used for evaluation of lung function in a number of pathophysiological conditions. We describe a telemetric method of non-invasive monitoring of the IPP in conscious animals intermittently or continuously for a prolonged period of time. MATERIALS AND METHODS: After IACUC approval, six mongrel dogs were used for the study. After sedation, each dog was intubated and anesthetized using 0.5% Isoflurane. A telemetric implant model TL11M2-D70-PCT from Data Science International was secured subcutaneously. The pressure sensor tip of the catheter from the implant was inserted into the pleural space, and the catheter was secured with sutures. The IPP signals were recorded at a sampling rate of 100 points/second for 30 to 60 min daily for 4 days. From these recordings, the total mean negative IPP (mmHg), and the total mean negative IPP for a standard time of 30 min were calculated. In addition, the actual inspiratory and expiratory pressures were also measured from stable recording of the IPP waveforms. RESULTS: In six dogs, the total mean +/- SD negative IPP was -10.8 +/- 10.6 mmHg. After normalizing with respect to acquisition time it was -13.2 +/- 11.2 mmHg/min. The actual inspiratory pressure was -19.7 +/- 15.3, and the expiratory pressure was -11.0 +/- 12.9. CONCLUSIONS: Our study demonstrates that telemetric monitoring of IPP can be performed reliably and non-invasively in conscious experimental animals. The values for IPP in our study are compatible with the results of other investigators who used different methods of IPP measurement. Further work may show this method to be helpful in understanding the pathophysiology of various breathing disorders.


Subject(s)
Exhalation/physiology , Inhalation/physiology , Manometry/instrumentation , Pleural Cavity/physiology , Telemetry/instrumentation , Animals , Catheterization , Consciousness , Dogs , Manometry/methods , Models, Animal , Motor Activity , Pressure , Telemetry/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...