Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
2.
Am J Cardiol ; 162: 24-30, 2022 01 01.
Article in English | MEDLINE | ID: mdl-34736721

ABSTRACT

Saphenous vein grafts (SVGs) have high rates of in-stent restenosis (ISR). We compared the baseline clinical and angiographic characteristics of patients and lesions that did develop ISR with those who did not develop ISR during a median follow-up of 2.7 years in the DIVA study (NCT01121224). We also examined the ISR types using the Mehran classification. ISR developed in 119 out of the 575 DIVA patients (21%), with similar incidence among patients with drug-eluting stents and bare-metal stents (BMS) (21% vs 21%, p = 0.957). Patients in the ISR group were younger (67 ± 7 vs 69 ± 8 years, p = 0.04) and less likely to have heart failure (27% vs 38%, p = 0.03) and SVG lesions with Thrombolysis In Myocardial Infarction 3 flow before the intervention (77% vs 83%, p <0.01), but had a higher number of target SVG lesions (1.33 ± 0.64 vs 1.16 ± 0.42, p <0.01), more stents implanted in the target SVG lesions (1.52 ± 0.80 vs 1.31 ± 0.66, p <0.01), and longer total stent length (31.37 ± 22.11 vs 25.64 ± 17.42 mm, p = 0.01). The incidence of diffuse ISR was similar in patients who received drug-eluting-stents and BMS (57% vs 54%, p = 0.94), but BMS patients were more likely to develop occlusive restenosis (17% vs 33%, p = 0.05).


Subject(s)
Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Coronary Restenosis/epidemiology , Drug-Eluting Stents/adverse effects , Graft Occlusion, Vascular/epidemiology , Saphenous Vein/transplantation , Age Factors , Aged , Coronary Angiography , Coronary Artery Disease/complications , Coronary Artery Disease/mortality , Coronary Restenosis/diagnosis , Female , Graft Occlusion, Vascular/diagnosis , Humans , Male , Middle Aged , Prosthesis Design , Risk Factors
4.
Circ Cardiovasc Interv ; 13(2): e008494, 2020 02.
Article in English | MEDLINE | ID: mdl-32019343

ABSTRACT

BACKGROUND: Direct stenting without pre-dilation or post-dilation has been advocated for saphenous vein graft percutaneous coronary intervention to decrease the incidence of distal embolization, periprocedural myocardial infarction, and target lesion revascularization. METHODS: We performed a post hoc analysis of patients enrolled in the DIVA (Drug-Eluting Stents Versus Bare Metal Stents in Saphenous Vein Graft Angioplasty; NCT01121224) prospective, double-blind, randomized controlled trial. Patients were stratified into stent-only and balloon-stent groups. Primary end point was 12-month incidence of target vessel failure (defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization). Secondary end points included all-cause death, stent thrombosis, myocardial infarction, and target lesion revascularization during follow-up. RESULTS: Of the 575 patients included in this substudy, 185 (32%) patients underwent stent-only percutaneous coronary intervention. Patients in the stent-only versus balloon-stent group had similar baseline characteristics and similar incidence of target vessel failure at 12-months (15% versus 19%; hazard ratio, 1.34 [95% CI, 0.86-2.08]; P=0.19). During long-term follow-up (median of 2.7 years), the incidence of definite stent thrombosis (1% versus 5%; hazard ratio, 9.20 [95% CI, 1.23-68.92]; P=0.0085), the composite of definite or probable stent thrombosis (5% versus 11%; hazard ratio, 2.52 [95% CI, 1.23-5.18]; P=0.009), and target vessel myocardial infarction (8% versus 14%; hazard ratio, 1.92 [95% CI, 1.08-3.40]; P=0.023) was lower in the stent-only group. Multivariable analysis showed that a higher number of years since coronary artery bypass grafting and >1 target saphenous vein graft lesions were associated with increased target vessel failure during entire follow-up, while preintervention Thrombolysis in Myocardial Infarction-3 flow was protective. CONCLUSIONS: In patients undergoing percutaneous coronary intervention of de novo saphenous vein graft lesions, there was no difference in target vessel failure at 12 months and long-term follow-up in the stent-only versus the balloon-stent group; however, the incidence of stent thrombosis was lower in the stent-only group, as was target vessel myocardial infarction. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01121224.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Angioplasty/instrumentation , Coronary Artery Bypass/adverse effects , Graft Occlusion, Vascular/therapy , Saphenous Vein/transplantation , Stents , Aged , Angioplasty/adverse effects , Angioplasty/mortality , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/mortality , Coronary Artery Bypass/mortality , Coronary Thrombosis/etiology , Double-Blind Method , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/mortality , Graft Occlusion, Vascular/physiopathology , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Prospective Studies , Risk Factors , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Time Factors , Treatment Outcome , United States , Vascular Patency
5.
Lancet ; 391(10134): 1997-2007, 2018 05 19.
Article in English | MEDLINE | ID: mdl-29759512

ABSTRACT

BACKGROUND: Few studies have examined the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure compared with bare-metal stents (BMS) in patients undergoing stenting of de-novo SVG lesions. We assessed the risks and benefits of the use of DES versus BMS in de-novo SVG lesions. METHODS: Patients were recruited to our double-blind, randomised controlled trial from 25 US Department of Veterans Affairs centres. Eligible participants were aged at least 18 years and had at least one significant de-novo SVG lesion (50-99% stenosis of a 2·25-4·5 mm diameter SVG) requiring percutaneous coronary intervention with intent to use embolic protection devices. Enrolled patients were randomly assigned, in a 1:1 ratio, by phone randomisation system to receive a DES or BMS. Randomisation was stratified by presence or absence of diabetes and number of target SVG lesions requiring percutaneous coronary intervention (one or two or more) within each participating site by use of an adaptive scheme intended to balance the two stent type groups on marginal totals for the stratification factors. Patients, referring physicians, study coordinators, and outcome assessors were masked to group allocation. The primary endpoint was the 12-month incidence of target vessel failure, defined as the composite of cardiac death, target vessel myocardial infarction, or target vessel revascularisation. The DIVA trial is registered with ClinicalTrials.gov, number NCT01121224. FINDINGS: Between Jan 1, 2012, and Dec 31, 2015, 599 patients were randomly assigned to the stent groups, and the data for 597 patients were used. The patients' mean age was 68·6 (SD 7·6) years, and 595 (>99%) patients were men. The two stent groups were similar for most baseline characteristics. At 12 months, the incidence of target vessel failure was 17% (51 of 292) in the DES group versus 19% (58 of 305) in the BMS group (adjusted hazard ratio 0·92, 95% CI 0·63-1·34, p=0·70). Between-group differences in the components of the primary endpoint, serious adverse events, or stent thrombosis were not significant. Enrolment was stopped before the revised target sample size of 762 patients was reached. INTERPRETATION: In patients undergoing stenting of de-novo SVG lesions, no significant differences in outcomes between those receiving DES and BMS during 12 months of follow-up were found. The study results have important economic implications in countries with high DES prices such as the USA, because they suggest that the lower-cost BMS can be used in SVG lesions without compromising either safety or efficacy. FUNDING: US Department of Veterans Affairs Cooperative Studies Program.


Subject(s)
Graft Rejection/drug therapy , Percutaneous Coronary Intervention/instrumentation , Saphenous Vein/surgery , Thrombosis/epidemiology , Aged , Double-Blind Method , Drug-Eluting Stents , Female , Humans , Male , Middle Aged , Self Expandable Metallic Stents , Thrombosis/etiology , Treatment Outcome
6.
Clin Cardiol ; 40(11): 946-954, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28841230

ABSTRACT

VA Cooperative Studies Program #571 (DIVA) was designed to evaluate the efficacy of drug-eluting stents (DES) for reducing aortocoronary saphenous vein bypass graft (SVG) failure when compared with bare-metal stents (BMS) in participants undergoing stenting of de novo SVG lesions. Participants undergoing clinically indicated stenting of de novo SVG lesions were randomized in a 1:1 ratio to DES or BMS. Randomization was stratified by presence/absence of diabetes mellitus and the number of target SVG lesions (1 vs ≥2) within each participating site. At sites that did not routinely administer 12-months of dual antiplatelet therapy after SVG stenting participants without acute coronary syndromes received 1 month of open-label clopidogrel, followed by 11 months of clopidogrel for those assigned to DES and 11 months of placebo for those assigned to BMS. The primary endpoint was the 12-month incidence of target-vessel failure (defined as the composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). Secondary endpoints included the incidence of other clinical endpoints and the incremental cost-effectiveness of DES relative to BMS. Due to lower-than-anticipated target-vessel failure rates, target enrollment was increased from 519 to 762. The study had randomized 599 participants when recruitment ended in December 2015. The DIVA trial will provide clarity on the appropriate stent type for de novo SVG lesions.


Subject(s)
Coronary Artery Bypass/adverse effects , Coronary Artery Disease/surgery , Drug-Eluting Stents , Graft Occlusion, Vascular/therapy , Metals , Percutaneous Coronary Intervention/instrumentation , Saphenous Vein/transplantation , Stents , Aged , Clinical Protocols , Coronary Artery Bypass/mortality , Coronary Artery Disease/mortality , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/mortality , Graft Occlusion, Vascular/physiopathology , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Platelet Aggregation Inhibitors/administration & dosage , Prospective Studies , Prosthesis Design , Research Design , Risk Factors , Saphenous Vein/diagnostic imaging , Saphenous Vein/physiopathology , Time Factors , Treatment Outcome , United States , United States Department of Veterans Affairs , Vascular Patency
7.
J Gen Intern Med ; 31(9): 1061-7, 2016 09.
Article in English | MEDLINE | ID: mdl-27234663

ABSTRACT

BACKGROUND: Effective management of patients using warfarin is resource-intensive, requiring frequent in-clinic testing of the international normalized ratio (INR). Patient self-testing (PST) using portable at-home INR monitoring devices has emerged as a convenient alternative. As revealed by The Home INR Study (THINRS), event rates for PST were not significantly different from those for in-clinic high-quality anticoagulation management (HQACM), and a cumulative gain in quality of life was observed for patients undergoing PST. OBJECTIVE: To perform a cost-utility analysis of weekly PST versus monthly HQACM and to examine the sensitivity of these results to testing frequency. PATIENTS/INTERVENTIONS: In this study, 2922 patients taking warfarin for atrial fibrillation or mechanical heart valve, and who demonstrated PST competence, were randomized to either weekly PST (n = 1465) or monthly in-clinic testing (n = 1457). In a sub-study, 234 additional patients were randomized to PST once every 4 weeks (n = 116) or PST twice weekly (n = 118). The endpoints were quality of life (measured by the Health Utilities Index), health care utilization, and costs over 2 years of follow-up. RESULTS: PST and HQACM participants were similar with regard to gender, age, and CHADS2 score. The total cost per patient over 2 years of follow-up was $32,484 for HQACM and $33,460 for weekly PST, representing a difference of $976. The incremental cost per quality-adjusted life year gained with PST once weekly was $5566 (95 % CI, -$11,490 to $25,142). The incremental cost-effectiveness ratio (ICER) was sensitive to testing frequency: weekly PST dominated PST twice weekly and once every 4 weeks. Compared to HQACM, weekly PST was associated with statistically significant and clinically meaningful improvements in quality of life. The ICER for weekly PST versus HQACM was well within accepted standards for cost-effectiveness, and was preferred over more or less frequent PST. These results were robust to sensitivity analyses of key assumptions. CONCLUSION: Weekly PST is a cost-effective alternative to monthly HQACM and a preferred testing frequency compared to twice weekly or monthly PST.


Subject(s)
Ambulatory Care Facilities/economics , Cost-Benefit Analysis/methods , Drug Monitoring/economics , Home Care Services/economics , International Normalized Ratio/economics , Self Care/economics , Adult , Aged , Aged, 80 and over , Ambulatory Care Facilities/standards , Anticoagulants/economics , Anticoagulants/therapeutic use , Cost-Benefit Analysis/standards , Drug Monitoring/methods , Drug Monitoring/standards , Female , Follow-Up Studies , Home Care Services/standards , Hospitals, Veterans/economics , Hospitals, Veterans/standards , Humans , International Normalized Ratio/methods , International Normalized Ratio/standards , Male , Middle Aged , Prospective Studies , Self Care/methods , Self Care/standards , Warfarin/economics , Warfarin/therapeutic use , Young Adult
8.
Am J Manag Care ; 22(1): 65-71, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26799126

ABSTRACT

OBJECTIVES: Patient self-testing (PST) improves anticoagulation control and patient satisfaction. It is unknown whether these effects are more pronounced when the patient lives farther from the anticoagulation clinic (ACC). If the benefits of PST are limited to a subset of patients (those living farther from care), selectively providing PST to that subset could enhance cost-effectiveness. STUDY DESIGN: This is a secondary analysis of a randomized trial of PST versus usual ACC care, which involved 2922 patients of the Veterans Health Administration (VHA). METHODS: Our 3 outcomes were the primary composite clinical end point (stroke, major hemorrhage, or death), anticoagulation control (percent time in therapeutic range), and satisfaction with anticoagulation care. We measured the driving distance between the patient's residence and the nearest VHA facility. We divided patients into quartiles by distance and looked for evidence of an interaction between distance and the effect of the intervention on the 3 outcomes. RESULTS: The median driving distance was 12 miles (interquartile range = 6-21). Patients living in the farthest quartile had higher rates of the primary composite clinical end point in both groups compared with patients living in the nearest quartile. For PST, the hazard ratio (HR) was 1.77 (95% CI, 1.18-2.64), and for usual care, the HR was 1.81 (95% CI, 1.19-2.75). Interaction terms did not suggest that distance to care modified the effect of the intervention on any outcome. CONCLUSIONS: The benefits of PST were not enhanced among patients living farther from care. Restricting PST to patients living more than a certain distance from the ACC is not likely to improve its cost-effectiveness.


Subject(s)
Anticoagulants/administration & dosage , Drug Monitoring , Point-of-Care Systems , Self Care , Travel/statistics & numerical data , Administration, Oral , Aged , Female , Health Services Accessibility , Humans , International Normalized Ratio , Male , Medication Adherence , Patient Satisfaction , Randomized Controlled Trials as Topic , United States , Veterans
9.
J Thromb Thrombolysis ; 40(1): 17-25, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25209313

ABSTRACT

Anticoagulation (AC) is effective in reducing thromboembolic events for individuals with atrial fibrillation (AF) or mechanical heart valve (MHV), but maintaining patients in target range for international normalized ratio (INR) can be difficult. Evidence suggests increasing INR testing frequency can improve time in target range (TTR), but this can be impractical with in-clinic testing. The objective of this study was to test the hypothesis that more frequent patient-self testing (PST) via home monitoring increases TTR. This planned substudy was conducted as part of The Home INR Study, a randomized controlled trial of in-clinic INR testing every 4 weeks versus PST at three different intervals. The setting for this study was 6 VA centers across the United States. 1,029 candidates with AF or MHV were trained and tested for competency using ProTime INR meters; 787 patients were deemed competent and, after second consent, randomized across four arms: high quality AC management (HQACM) in a dedicated clinic, with venous INR testing once every 4 weeks; and telephone monitored PST once every 4 weeks; weekly; and twice weekly. The primary endpoint was TTR at 1-year follow-up. The secondary endpoints were: major bleed, stroke and death, and quality of life. Results showed that TTR increased as testing frequency increased (59.9 ± 16.7 %, 63.3 ± 14.3 %, and 66.8 ± 13.2 % [mean ± SD] for the groups that underwent PST every 4 weeks, weekly and twice weekly, respectively). The proportion of poorly managed patients (i.e., TTR <50 %) was significantly lower for groups that underwent PST versus HQACM, and the proportion decreased as testing frequency increased. Patients and their care providers were unblinded given the nature of PST and HQACM. In conclusion, more frequent PST improved TTR and reduced the proportion of poorly managed patients.


Subject(s)
Home Care Services/standards , International Normalized Ratio/standards , Prothrombin Time/standards , Self Care/standards , United States Department of Veterans Affairs/standards , Aged , Drug Monitoring/methods , Drug Monitoring/standards , Female , Follow-Up Studies , Humans , International Normalized Ratio/methods , Male , Middle Aged , Prothrombin Time/methods , Self Care/methods , Time Factors , United States
10.
Lancet ; 379(9813): 322-34, 2012 Jan 28.
Article in English | MEDLINE | ID: mdl-22137798

ABSTRACT

BACKGROUND: Uptake of self-testing and self-management of oral anticoagulation [corrected] has remained inconsistent, despite good evidence of their effectiveness. To clarify the value of self-monitoring of oral anticoagulation, we did a meta-analysis of individual patient data addressing several important gaps in the evidence, including an estimate of the effect on time to death, first major haemorrhage, and thromboembolism. METHODS: We searched Ovid versions of Embase (1980-2009) and Medline (1966-2009), limiting searches to randomised trials with a maximally sensitive strategy. We approached all authors of included trials and requested individual patient data: primary outcomes were time to death, first major haemorrhage, and first thromboembolic event. We did prespecified subgroup analyses according to age, type of control-group care (anticoagulation-clinic care vs primary care), self-testing alone versus self-management, and sex. We analysed patients with mechanical heart valves or atrial fibrillation separately. We used a random-effect model method to calculate pooled hazard ratios and did tests for interaction and heterogeneity, and calculated a time-specific number needed to treat. FINDINGS: Of 1357 abstracts, we included 11 trials with data for 6417 participants and 12,800 person-years of follow-up. We reported a significant reduction in thromboembolic events in the self-monitoring group (hazard ratio 0·51; 95% CI 0·31-0·85) but not for major haemorrhagic events (0·88, 0·74-1·06) or death (0·82, 0·62-1·09). Participants younger than 55 years showed a striking reduction in thrombotic events (hazard ratio 0·33, 95% CI 0·17-0·66), as did participants with mechanical heart valve (0·52, 0·35-0·77). Analysis of major outcomes in the very elderly (age ≥85 years, n=99) showed no significant adverse effects of the intervention for all outcomes. INTERPRETATION: Our analysis showed that self-monitoring and self-management of oral coagulation is a safe option for suitable patients of all ages. Patients should also be offered the option to self-manage their disease with suitable health-care support as back-up. FUNDING: UK National Institute for Health Research (NIHR) Technology Assessment Programme, UK NIHR National School for Primary Care Research.


Subject(s)
Anticoagulants/administration & dosage , Drug Monitoring , Self Care , Thromboembolism/prevention & control , Administration, Oral , Anticoagulants/adverse effects , Hemorrhage/chemically induced , Humans , International Normalized Ratio , Vitamin K/antagonists & inhibitors
11.
N Engl J Med ; 363(17): 1608-20, 2010 Oct 21.
Article in English | MEDLINE | ID: mdl-20961244

ABSTRACT

BACKGROUND: Warfarin anticoagulation reduces thromboembolic complications in patients with atrial fibrillation or mechanical heart valves, but effective management is complex, and the international normalized ratio (INR) is often outside the target range. As compared with venous plasma testing, point-of-care INR measuring devices allow greater testing frequency and patient involvement and may improve clinical outcomes. METHODS: We randomly assigned 2922 patients who were taking warfarin because of mechanical heart valves or atrial fibrillation and who were competent in the use of point-of-care INR devices to either weekly self-testing at home or monthly high-quality testing in a clinic. The primary end point was the time to a first major event (stroke, major bleeding episode, or death). RESULTS: The patients were followed for 2.0 to 4.75 years, for a total of 8730 patient-years of follow-up. The time to the first primary event was not significantly longer in the self-testing group than in the clinic-testing group (hazard ratio, 0.88; 95% confidence interval, 0.75 to 1.04; P=0.14). The two groups had similar rates of clinical outcomes except that the self-testing group reported more minor bleeding episodes. Over the entire follow-up period, the self-testing group had a small but significant improvement in the percentage of time during which the INR was within the target range (absolute difference between groups, 3.8 percentage points; P<0.001). At 2 years of follow-up, the self-testing group also had a small but significant improvement in patient satisfaction with anticoagulation therapy (P=0.002) and quality of life (P<0.001). CONCLUSIONS: As compared with monthly high-quality clinic testing, weekly self-testing did not delay the time to a first stroke, major bleeding episode, or death to the extent suggested by prior studies. These results do not support the superiority of self-testing over clinic testing in reducing the risk of stroke, major bleeding episode, and death among patients taking warfarin therapy. (Funded by the Department of Veterans Affairs Cooperative Studies Program; ClinicalTrials.gov number, NCT00032591.).


Subject(s)
Anticoagulants/therapeutic use , Drug Monitoring/methods , International Normalized Ratio , Self Care , Warfarin/therapeutic use , Aged , Anticoagulants/adverse effects , Atrial Fibrillation/drug therapy , Female , Follow-Up Studies , Heart Valve Prosthesis , Hemorrhage/epidemiology , Hemorrhage/prevention & control , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Mortality , Myocardial Infarction/epidemiology , Prospective Studies , Stroke/epidemiology , Stroke/prevention & control , Thrombosis/prevention & control , Warfarin/adverse effects
12.
J Thromb Thrombolysis ; 30(3): 263-75, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20628787

ABSTRACT

Prior studies suggest patient self-testing (PST) of prothrombin time (PT) can improve the quality of anticoagulation (AC) and reduce complications (e.g., bleeding and thromboembolic events). "The Home INR Study" (THINRS) compared AC management with frequent PST using a home monitoring device to high-quality AC management (HQACM) with clinic-based monitoring on major health outcomes. A key clinical and policy question is whether and which patients can successfully use such devices. We report the results of Part 1 of THINRS in which patients and caregivers were evaluated for their ability to perform PST. Study-eligible patients (n = 3643) were trained to use the home monitoring device and evaluated after 2-4 weeks for PST competency. Information about demographics, medical history, warfarin use, medications, plus measures of numeracy, literacy, cognition, dexterity, and satisfaction with AC were collected. Approximately 80% (2931 of 3643) of patients trained on PST demonstrated competency; of these, 8% (238) required caregiver assistance. Testers who were not competent to perform PST had higher numbers of practice attempts, higher cuvette wastage, and were less able to perform a fingerstick or obtain blood for the cuvette in a timely fashion. Factors associated with failure to pass PST training included increased age, previous stroke history, poor cognition, and poor manual dexterity. A majority of patients were able to perform PST. Successful home monitoring of PT with a PST device required adequate levels of cognition and manual dexterity. Training a caregiver modestly increased the proportion of patients who can perform PST.


Subject(s)
Drug Monitoring/methods , Patient Selection , Prothrombin Time/methods , Self Care/instrumentation , Adult , Aged , Aged, 80 and over , Anticoagulants/therapeutic use , Atrial Fibrillation , Costs and Cost Analysis , Drug Monitoring/standards , Female , Heart Valve Prosthesis , Hemorrhage , Humans , International Normalized Ratio , Male , Middle Aged , Prothrombin Time/instrumentation , ROC Curve , Self Care/methods , Warfarin/therapeutic use , Young Adult
13.
Circulation ; 119(24): 3093-100, 2009 Jun 23.
Article in English | MEDLINE | ID: mdl-19506112

ABSTRACT

BACKGROUND: In animal studies and a pilot trial in patients with congestive heart failure, the thyroid hormone analog 3,5 diiodothyropropionic acid (DITPA) had beneficial hemodynamic effects. METHODS AND RESULTS: This was a phase II multicenter, randomized, placebo-controlled, double-blind trial of New York Heart Association class II to IV congestive heart failure patients randomized (2:1) to DITPA or placebo and treated for 6 months. The study enrolled 86 patients (n=57 to DITPA, n=29 to placebo). The primary objective was to assess the effect of DITPA on a composite congestive heart failure end point that classifies patients as improved, worsened, or unchanged based on symptom changes and morbidity/mortality. DITPA was poorly tolerated, which obscured the interpretation of congestive heart failure-specific effects. Fatigue and gastrointestinal complaints, in particular, were more frequent in the DITPA group. DITPA increased cardiac index (by 18%) and decreased systemic vascular resistance (by 11%), serum cholesterol (-20%), low-density lipoprotein cholesterol (-30%), and body weight (-11 lb). Thyroid-stimulating hormone was suppressed in patients given DITPA, which reflects its thyromimetic effect; however, no symptoms or signs of potential hypothyroidism or thyrotoxicosis were seen. CONCLUSIONS: DITPA improved some hemodynamic and metabolic parameters, but there was no evidence for symptomatic benefit in congestive heart failure.


Subject(s)
Diiodothyronines/administration & dosage , Diiodothyronines/adverse effects , Heart Failure/drug therapy , Propionates/administration & dosage , Propionates/adverse effects , Adolescent , Adult , Aged , Body Weight , Cholesterol/blood , Double-Blind Method , Fatigue/blood , Fatigue/chemically induced , Female , Gastrointestinal Diseases/blood , Gastrointestinal Diseases/chemically induced , Heart Failure/blood , Humans , Lipoproteins, LDL/blood , Male , Middle Aged , Thyroid Hormones , United States , United States Department of Veterans Affairs , Vascular Resistance/drug effects
14.
J Thromb Thrombolysis ; 19(3): 163-72, 2005 Jun.
Article in English | MEDLINE | ID: mdl-16082603

ABSTRACT

BACKGROUND: Anticoagulation (AC) with warfarin reduces the risk of thromboembolism (TE) in a variety of applications, yet despite compelling evidence of the value and importance of high quality AC, warfarin remains underused, and dosing is often suboptimal. Approaches to improve AC quality include (1) an AC service (ACS), which allows the physician to delegate day-to-day details of AC management to another provider dedicated to AC care, and (2) incorporating into the treatment plan patient self-testing (PST) under which, after completing a training program, patients perform their own blood testing (typically, using a finger-stick blood analyzer), have dosage adjustments guided by a standard protocol, and forward test results, dosing and other information to the provider. Studies have suggested that PST can improve the quality of AC and perhaps lower TE and bleed rates. The purpose of Department of Veterans Affairs (VA) Cooperative Studies Program (CSP) #481, "The Home INR Study" (THINRS) is to compare AC management with frequent PST using a home monitoring device to high quality AC management (HQACM) implemented by an ACS with conventional monitoring of prothrombin time by international normalized ratio (INR) on major health outcomes. PST in THINRS involves use of an INR monitoring device that is FDA approved for home use. STUDY DESIGN: Sites are VA Medical Centers where the ACS has an active roster of more than 400 patients. THINRS includes patients with atrial fibrillation (AF) and/or mechanical heart valve (MHV) expected to be anticoagulated indefinitely. THINRS has two parts. In Part 1, candidates for PST are evaluated for 2 to 4 weeks for their ability to use home monitoring devices. In Part 2, individuals capable of performing PST are randomized to (1) HQACM with testing every 4 weeks and as indicated for out of range values, medication/clinical changes, or (2) PST with testing every week and as indicated for out of range values, medication/clinical changes. The primary outcome measure is event rates, defined as the percent of patients who have a stroke, major bleed, or die. Secondary outcomes include total time in range (TTR), other events (myocardial infarction (MI), non-stroke TE, minor bleeds), competence and compliance with PST, satisfaction with AC, AC associated quality of life (QOL), and cost-effectiveness. To assess the effect of PST frequency on TTR and other outcomes, at selected sites patients randomized to perform PST are assigned one of three test frequencies (weekly, twice weekly, or once every four weeks).


Subject(s)
Anticoagulants/blood , Clinical Protocols , Drug Monitoring , Prothrombin Time , Self Care , Anticoagulants/administration & dosage , Anticoagulants/pharmacokinetics , Cardiovascular Diseases/drug therapy , Cardiovascular Diseases/prevention & control , Humans , International Normalized Ratio/instrumentation , Prothrombin Time/methods , Quality of Health Care
15.
J Clin Psychopharmacol ; 22(2): 196-200, 2002 Apr.
Article in English | MEDLINE | ID: mdl-11910266

ABSTRACT

Predictors for the development of tardive dyskinesia (TD) have been studied extensively over the years, yet there are few studies of predictors of the course of TD after it has developed. Moreover, few studies have examined predictors of the course of other extrapyramidal side effects (EPS) in patients maintained on neuroleptics. The purpose of this study was to determine which modifiable variables are important in the prediction of EPS in patients with persistent TD over a period of as long as 2 years. One hundred fifty-eight patients enrolled in the Veterans Affairs Cooperative Study 394 were included in this study. A linear mixed-effects (LME) analysis to estimate the Abnormal Involuntary Movement Scale score (for TD severity), Simpson-Angus Scale (for parkinsonism severity), and Barnes Akathisia Scale at any given time after intake assessment was performed. The severity of each of the TD and EPS outcomes at any given visit was predicted by their respective baseline severity scores. Additional predictors of a favorable course of TD included lower doses of antipsychotic medications and use of anticholinergic medications. Other predictors of a favorable course of EPS included younger age and the use of atypical antipsychotic medication (for rigidity) and the use of anticholinergic medication (for tremor). These findings indicate that clinician-modifiable factors related to medication usage can influence the outcome of TD and EPS in patients with persistent TD.


Subject(s)
Antipsychotic Agents/adverse effects , Basal Ganglia Diseases/chemically induced , Dyskinesia, Drug-Induced/etiology , Veterans/psychology , Adult , Aged , Antipsychotic Agents/therapeutic use , Basal Ganglia Diseases/diagnosis , Dyskinesia, Drug-Induced/diagnosis , Female , Humans , Long-Term Care , Male , Middle Aged , Neurologic Examination/drug effects , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...