Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
2.
J Med Toxicol ; 20(1): 10-12, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38010564

Subject(s)
Poisons , Humans , Writing
3.
Ann Emerg Med ; 81(4): 495-500, 2023 04.
Article in English | MEDLINE | ID: mdl-36754698

ABSTRACT

STUDY OBJECTIVE: Developed to decrease unnecessary thoracic computed tomography use in adult blunt trauma patients, the National Emergency X-Radiography Utilization Study (NEXUS) Chest clinical decision instrument does not include the extended Focused Assessment with Sonography in Trauma (eFAST). We assessed whether eFAST improves the NEXUS Chest clinical decision instrument's diagnostic performance and may replace the chest radiograph (CXR) as a predictor variable. METHODS: We performed a secondary analysis of prospective data from 8 Level I trauma centers from 2011-2014. We compared performance of modified clinical decision instruments that (1) added eFAST as a predictor (eFAST-added clinical decision instrument), and (2) replaced CXR with eFAST (eFAST-replaced clinical decision instrument), in screening for blunt thoracic injuries. RESULTS: One thousand nine hundred fifty-seven patients had documented computed tomography, CXR, clinical NEXUS criteria, and adequate eFAST; 624 (31.9%) patients had blunt thoracic injuries, and 126 (6.4%) had major injuries. Compared to the NEXUS Chest clinical decision instrument, the eFAST-added clinical decision instrument demonstrated unchanged screening performance for major injury (sensitivity 0.98 [0.94 to 1.00], specificity 0.28 [0.26 to 0.30]) or any injury (sensitivity 0.97 [0.95 to 0.98], specificity 0.21 [0.19 to 0.23]). The eFAST-replaced clinical decision instrument demonstrated unchanged sensitivity for major injury (sensitivity 0.93 [0.87 to 0.97], specificity 0.31 [0.29 to 0.34]) and decreased sensitivity for any injury (0.93 [0.91 to 0.951] versus 0.97 [0.953 to 0.98]). CONCLUSION: In our secondary analysis, adding eFAST as a predictor variable did not improve the diagnostic screening performance of the original NEXUS Chest clinical decision instrument; eFAST cannot replace the CXR criterion of the NEXUS Chest clinical decision instrument.


Subject(s)
Focused Assessment with Sonography for Trauma , Thoracic Injuries , Wounds, Nonpenetrating , Adult , Humans , Prospective Studies , Sensitivity and Specificity , Thoracic Injuries/diagnostic imaging , Radiography, Thoracic/methods , Wounds, Nonpenetrating/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...