Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Anal Bioanal Chem ; 354(7-8): 903-9, 1996 Mar.
Article in English | MEDLINE | ID: mdl-15048414

ABSTRACT

A technique for precise boron isotope ratio measurements with a high detection power has been developed by negative thermal ionization mass spectrometry (NTIMS). Relative standard deviations in the range of 0.03-0.3% have been obtained for the determination of the (11)B/(10)B isotope ratio using nanogram amounts of boron. Ba(OH)(2) has been applied as ionization promoter for the formation of negative thermal ions. By adding MgCl(2) better reproducibilities of the measurement have been achieved. A possible interference of BO(-)(2) ions at mass number 42 by CNO(-) could be excluded by the sample preparation technique used. Contrary to other NTI techniques no dependence of the measured isotope ratio on the boron amount used has been observed. Anthropogenic and natural saline influences in ground water have been successfully identified by boron isotope ratio determinations with this NTIMS method, due to the different isotopic composition of boron in natural and anthropogenic substances. In sewage, the boron isotope ratio is substantially influenced by washing powder, which contains low (11)B/(10)B ratios (expressed in delta(11)B values normalized to the standard reference material NIST SRM 951). In contaminated ground water, low delta(11)B values are normally correlated with high boron and high chloride concentrations. On the other hand, delta(11)B shifts to higher values in less contaminated samples. For ground water with saline influences, only the delta(11)B determination, and not the boron or chloride content, allowed the correct identification of this natural source of contamination.

2.
Monatsschr Kinderheilkd ; 138(9): 631-4, 1990 Sep.
Article in German | MEDLINE | ID: mdl-2233767

ABSTRACT

The role of the clonidine suppression test and determination of the plasma concentration of noradrenaline and of neuropeptide Y (NPY) for the diagnosis and monitoring of bilateral pheochromocytoma was studied in a ten year old girl. Prior to tumor removal plasma concentration of noradrenaline (25.9 nmol/l) and NPY (14 pmol/l) were markedly elevated. Inhibition of central sympathetic activity by clonidine (150 micrograms orally) did not lower the plasma concentration of noradrenaline (70.4 nmol/l) and NPY (52.6 pmol/l). However in an adolescent boy with renal hypertension plasma concentration of noradrenaline and NPY fell following clonidine application (noradrenaline from 1.9 to 1.3 nmol/l, NPY from 3.6 to 2.4 pmol/l). After complete removal of the pheochromocytoma noradrenaline and NPY fell back to normal.


Subject(s)
Adrenal Gland Neoplasms/diagnosis , Clonidine , Neoplasms, Multiple Primary/diagnosis , Neuropeptide Y/blood , Norepinephrine/blood , Pheochromocytoma/diagnosis , Adrenal Gland Neoplasms/blood , Child , Female , Humans , Neoplasms, Multiple Primary/blood , Pheochromocytoma/blood
SELECTION OF CITATIONS
SEARCH DETAIL
...