Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Front Neurol ; 12: 679918, 2021.
Article in English | MEDLINE | ID: mdl-34456844

ABSTRACT

Objective: The aim of this study is to evaluate the evolution of GPi DBS targeting. Methods: This retrospective, single-center study included patients implanted with GPi DBS leads for dystonia or PD during the years 2004 to 2018 at the University of Florida Fixel Institute for Neurological Diseases. Each patient underwent a high-resolution targeting study on the day prior to the surgery, which was fused with a high resolution CT scan that was acquired on the day of the procedure. Intraoperative target location was selected using a digitized 3D Schaltenbrand-Bailey atlas. All patients underwent a high-resolution head CT scan without contrast approximately one month after lead implantation and accurate measurement of neuroanatomical lead position was acquired after fusion of pre-operative and post-operative image studies. Results: We analyzed 253 PD patients with 352 leads and 80 dystonia patients with 141 leads. During 15 years of follow-up, lead locations in the PD group migrated more laterally (ß = 0.09, p < 0.0001), posteriorly [slope (ß) = 0.04, p < 0.05], and dorsally (ß = 0.07, p < 0.001), whereas leads in the dystonia group did not significantly change position aside from a trend in the dorsal direction (ß = 0.06, p = 0.053). Conclusion: The evolving target likely results from multiple factors including improvements in targeting techniques and clinical feedback intraoperatively and post-operatively. Our demonstrates the potential importance of a systematic post-operative DBS lead measurement protocol to ensure quality control and to inform and optimize DBS programming.

2.
J Bras Pneumol ; 45(1): e20170373, 2019 Feb 11.
Article in English, Portuguese | MEDLINE | ID: mdl-30758428

ABSTRACT

OBJECTIVE: Minimally invasive repair of pectus excavatum (MIRPE) is a surgical treatment for PE. During the procedure, a specialized introducer is used to tunnel across the mediastinum for thoracoscopic insertion of a metal bar. There have been reported cases of cardiac perforation during this risky step. The large introducer can be a dangerous lever in unskilled hands. We set out to determine the safety and feasibility of using regular instruments (i.e., not relying on special devices or tools) to create the retrosternal tunnel during MIRPE. METHODS: This was a preliminary study of MIRPE with regular instruments (MIRPERI), involving 28 patients with PE. We recorded basic patient demographics, chest measurements, and surgical details, as well as intraoperative and postoperative complications. RESULTS: Patients undergoing MIRPERI had Haller index values ranging from 2.58 to 5.56. No intraoperative complications occurred. Postoperative complications included nausea/vomiting in 8 patients, pruritus in 2, and dizziness in 2, as well as atelectasis, pneumothorax with thoracic drainage, pleural effusion, and dyspnea in 1 patient each. CONCLUSIONS: In this preliminary study, the rate of complications associated with MIRPERI was comparable to that reported in the literature for MIRPE. The MIRPERI approach has the potential to improve the safety of PE repair, particularly for surgeons that do not have access to certain special instruments or have not been trained in their use.


Subject(s)
Funnel Chest/surgery , Thoracoscopy/instrumentation , Adolescent , Adult , Female , Funnel Chest/diagnostic imaging , Humans , Intraoperative Complications , Male , Medical Illustration , Postoperative Complications , Prospective Studies , Reproducibility of Results , Risk Factors , Sternum/surgery , Thoracoscopy/adverse effects , Thoracoscopy/methods , Tomography, X-Ray Computed , Treatment Outcome , Young Adult
3.
J. bras. pneumol ; 45(1): e20170373, 2019. tab, graf
Article in English | LILACS | ID: biblio-984617

ABSTRACT

ABSTRACT Objective: Minimally invasive repair of pectus excavatum (MIRPE) is a surgical treatment for PE. During the procedure, a specialized introducer is used to tunnel across the mediastinum for thoracoscopic insertion of a metal bar. There have been reported cases of cardiac perforation during this risky step. The large introducer can be a dangerous lever in unskilled hands. We set out to determine the safety and feasibility of using regular instruments (i.e., not relying on special devices or tools) to create the retrosternal tunnel during MIRPE. Methods: This was a preliminary study of MIRPE with regular instruments (MIRPERI), involving 28 patients with PE. We recorded basic patient demographics, chest measurements, and surgical details, as well as intraoperative and postoperative complications. Results: Patients undergoing MIRPERI had Haller index values ranging from 2.58 to 5.56. No intraoperative complications occurred. Postoperative complications included nausea/vomiting in 8 patients, pruritus in 2, and dizziness in 2, as well as atelectasis, pneumothorax with thoracic drainage, pleural effusion, and dyspnea in 1 patient each. Conclusions: In this preliminary study, the rate of complications associated with MIRPERI was comparable to that reported in the literature for MIRPE. The MIRPERI approach has the potential to improve the safety of PE repair, particularly for surgeons that do not have access to certain special instruments or have not been trained in their use.


RESUMO Objetivo: O minimally invasive repair of pectus excavatum (MIRPE, reparo minimamente invasivo do pectus excavatum) é um tratamento cirúrgico do PE. Durante o procedimento, utiliza-se um introdutor específico a fim de criar um túnel mediastinal para a colocação toracoscópica de uma barra metálica. Já houve casos relatados de perfuração cardíaca durante essa etapa arriscada. O introdutor grande pode ser uma perigosa alavanca em mãos inábeis. Propusemo-nos a determinar a segurança e viabilidade do uso de instrumentos comuns (isto é, sem contar com dispositivos ou ferramentas especiais) para criar o túnel retroesternal durante o MIRPE. Métodos: Estudo preliminar sobre o MIRPE with regular instruments (MIRPERI, MIRPE com instrumentos comuns), envolvendo 28 pacientes com PE. Foram registrados dados demográficos básicos dos pacientes, medições torácicas e detalhes cirúrgicos, bem como complicações intra e pós-operatórias. Resultados: Os pacientes submetidos ao MIRPERI apresentavam índice de Haller entre 2,58 e 5,56. Não ocorreram complicações intraoperatórias. As complicações pós-operatórias incluíram náusea/vômito em 8 pacientes, prurido em 2 e tontura em 2, bem como atelectasia, pneumotórax com drenagem torácica, derrame pleural e dispneia em 1 paciente cada. Conclusões: Neste estudo preliminar, a taxa de complicações associadas ao MIRPERI foi comparável à relatada na literatura para o MIRPE. A abordagem de MIRPERI tem o potencial de melhorar a segurança do reparo do PE, particularmente para cirurgiões que não têm acesso a certos instrumentos especiais ou não foram treinados para utilizá-los.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Young Adult , Thoracoscopy/instrumentation , Funnel Chest/surgery , Postoperative Complications , Sternum/surgery , Thoracoscopy/adverse effects , Thoracoscopy/methods , Tomography, X-Ray Computed , Prospective Studies , Reproducibility of Results , Risk Factors , Treatment Outcome , Funnel Chest/diagnostic imaging , Intraoperative Complications , Medical Illustration
SELECTION OF CITATIONS
SEARCH DETAIL
...