Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Eur J Cardiothorac Surg ; 61(1): 152-159, 2021 Dec 27.
Article in English | MEDLINE | ID: mdl-34355742

ABSTRACT

OBJECTIVES: We investigated the anatomical evolution of residual aortic dissection after type A repair and factors associated with poor prognosis at a high-volume aortic centre. METHODS: Between 2017 and 2019, all type A aortic dissections were included for prospective follow-up. Patients without follow-up computed tomography (CT) scan available for radiological analysis and patients without residual aortic dissection were excluded from this study. The primary end point was a composite end point defined as dissection-related events including aneurysmal evolution (increased diameter > 5 mm/year), aortic reintervention for malperfusion syndrome, aortic diameter >55 mm, rapid aortic growth >10 mm/year or aortic rupture and death. The secondary end points were risk factors for dissection-related events and reintervention analysis. All immediate and last postoperative CT scans were analysed. RESULTS: Among 104 patients, after a mean follow-up of 20.4 months (8-41), the risk of dissection-related events was 46.1% (48/104) and the risk of distal reintervention was 17.3% (18/104). Marfan syndrome (P < 0.01), aortic bicuspid valve (P = 0.038), innominate artery debranching (P = 0.025), short aortic cross-clamp time (P = 0.011), initial aortic diameter >40 mm (P < 0.01) and absence of resection of the primary entry tear (P = 0.015) were associated with an increased risk of dissection-related events or reintervention during follow-up. CONCLUSIONS: Residual aortic dissection is a serious disease requiring close follow-up at an expert centre. This study shows higher reintervention and aneurysmal development rates than currently published. To improve long-term outcomes, the early demographic and anatomic poor prognostic factors identified may be used for more aggressive treatment at an early phase.


Subject(s)
Aortic Aneurysm, Thoracic , Aortic Dissection , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aortic Dissection/complications , Aortic Dissection/diagnostic imaging , Aortic Dissection/surgery , Aortic Aneurysm, Thoracic/complications , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Follow-Up Studies , Humans , Postoperative Complications/etiology , Prospective Studies , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome
2.
Circ Cardiovasc Imaging ; 13(6): e009886, 2020 06.
Article in English | MEDLINE | ID: mdl-32507018

ABSTRACT

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9-20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29-48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90-95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90-95) and 39% (95% CI, 27-50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9-9.6). DUS sensitivity reached 73% (95% CI, 51-96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT01230203.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Blood Vessel Prosthesis Implantation , Computed Tomography Angiography , Endovascular Procedures , Multidetector Computed Tomography , Postoperative Complications/diagnostic imaging , Ultrasonography, Doppler, Color , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , France , Humans , Male , Postoperative Complications/therapy , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Retreatment , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...