Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 25(16): 18703-18712, 2017 Aug 07.
Article in English | MEDLINE | ID: mdl-29041065

ABSTRACT

Lateral optical distortion is present in most optical imaging systems. In coherence scanning interferometry, distortion may cause field-dependent systematic errors in the measurement of surface topography. These errors become critical when high-precision surfaces, e.g. precision optics, are measured. Current calibration and correction methods for distortion require some form of calibration artefact that has a smooth local surface and a grid of high-precision manufactured features. Moreover, to ensure high accuracy and precision of the absolute and relative locations of the features of these artefacts, requires their positions to be determined using a traceable measuring instrument, e.g. a metrological atomic force microscope. Thus, the manufacturing and calibration processes for calibration artefacts are often expensive and complex. In this paper, we demonstrate for the first time the calibration and correction of optical distortion in a coherence scanning interferometer system by using an arbitrary surface that contains some deviations from flat and has some features (possibly just contamination), such that feature detection is possible. By using image processing and a self-calibration technique, a precision of a few nanometres is achieved for the distortion correction. An inexpensive metal surface, e.g. the surface of a coin, or a scratched and defected mirror, which can be easily found in a laboratory or workshop, may be used. The cost of the distortion correction with nanometre level precision is reduced to almost zero if the absolute scale is not required. Although an absolute scale is still needed to make the calibration traceable, the problem of obtaining the traceability is simplified as only a traceable measure of the distance between two arbitrary points is needed. Thus, the total cost of transferring the traceability may also be reduced significantly using the proposed method.

2.
Appl Opt ; 56(10): 2912-2921, 2017 Apr 01.
Article in English | MEDLINE | ID: mdl-28375261

ABSTRACT

Accurate dimensional measurement of micro-milled items is a challenge and machine specifications do not include operational parameters in the workshop. Therefore, a verification test that shows the machine's overall geometrical performance over its working area would help machine users in the assessment and adjustment of their equipment. In this study, we present an optical technique capable of finding micro-milled features at submicron uncertainty over working areas >10 cm2. The technique relies on an ultra-precision measurement microscope combined with advanced image analysis to get the center of gravity of milled cross-shaped features at subpixel levels. Special algorithms had to be developed to handle the disturbing influence of burr and milling marks. The results show repeatability, reproducibility, and axis straightness for three micro-milling facilities and also discovered an unknown 2 µm amplitude undulation in one of them.

3.
J Opt Soc Am A Opt Image Sci Vis ; 31(2): 217-26, 2014 Feb 01.
Article in English | MEDLINE | ID: mdl-24562018

ABSTRACT

Optical coherence tomography (OCT) is useful for materials defect analysis and inspection with the additional possibility of quantitative dimensional metrology. Here, we present an automated image-processing algorithm for OCT analysis of roll-to-roll multilayers in 3D manufacturing of advanced ceramics. It has the advantage of avoiding filtering and preset modeling, and will, thus, introduce a simplification. The algorithm is validated for its capability of measuring the thickness of ceramic layers, extracting the boundaries of embedded features with irregular shapes, and detecting the geometric deformations. The accuracy of the algorithm is very high, and the reliability is better than 1 µm when evaluating with the OCT images using the same gauge block step height reference. The method may be suitable for industrial applications to the rapid inspection of manufactured samples with high accuracy and robustness.


Subject(s)
Algorithms , Ceramics/chemistry , Image Processing, Computer-Assisted/methods , Tomography, Optical Coherence/methods , Automation , Fourier Analysis , Materials Testing , Signal-To-Noise Ratio , Time Factors
4.
J Opt Soc Am A Opt Image Sci Vis ; 31(12): 2551-60, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25606743

ABSTRACT

Optical coherence tomography (OCT) has proven to be a useful tool for investigating internal structures in ceramic tapes, and the technique is expected to be important for roll-to-roll manufacturing. However, because of high scattering in ceramic materials, noise and speckles deteriorate the image quality, which makes automated quantitative measurements of internal interfaces difficult. To overcome this difficulty we present in this paper an innovative image analysis approach based on volumetric OCT data. The engine in the analysis is a 3D image processing and analysis algorithm. It is dedicated to boundary segmentation and dimensional measurement in volumetric OCT images, and offers high accuracy, efficiency, robustness, subpixel resolution, and a fully automated operation. The method relies on the correlation property of a physical interface and effectively eliminates pixels caused by noise and speckles. The remaining pixels being stored are the ones confirmed to be related to the target interfaces. Segmentation of tilted and curved internal interfaces separated by ∼10 µm in the Z direction is demonstrated. The algorithm also extracts full-field top-view intensity maps of the target interfaces for high-accuracy measurements in the X and Y directions. The methodology developed here may also be adopted in other similar 3D imaging and measurement technologies, e.g., ultrasound imaging, and for various materials.

5.
Opt Express ; 20(4): 4603-18, 2012 Feb 13.
Article in English | MEDLINE | ID: mdl-22418218

ABSTRACT

Large-scale and cost-effective manufacturing of ceramic micro devices based on tape stacking requires the development of inspection systems to perform high-resolution in-process quality control of embedded manufactured cavities, metal structures and defects. With an optical coherence tomography (OCT) system operating at 1.3 µm and a dedicated automated line segmentation algorithm, layer thicknesses can be measured and laser-machined channels can be verified in alumina ceramics embedded at around 100 µm depth. Monte Carlo simulations are employed to analyze the abilities of OCT in imaging of the embedded channels. The light scattering parameters required as input data for simulations are evaluated from the integrating sphere measurements of collimated and diffuse transmittance spectra using a reconstruction algorithm based on refined diffusion approximation approach.

SELECTION OF CITATIONS
SEARCH DETAIL
...