Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Reprod Toxicol ; 123: 108516, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38042436

ABSTRACT

There is evidence that sperm count has progressively declined in men over the recent decades. Exposure to air pollutants including petrol and diesel exhaust have been reported to impair male reproduction although there is little experimental evidence. This study investigated the effects of petrol-generator exhaust fumes (PGEF) on semen, sperm, gonadal structure and hormonal status in the dog. Sixteen adult male Basenji dogs were randomly assigned four to each of 4 groups as follows: an unexposed (Control) group and three groups exposed to graded levels of PGEF for 1, 2 or 3 h per day (hpd), respectively, for 90 days. Serum concentrations of testosterone (T), follicle stimulating hormone (FSH) and luteinizing hormone (LH) were measured on days 0 (baseline), 30, 60 and 90 of the study. At day 90, semen samples were collected for semen and sperm analysis. Testicular and epididymal tissues were subjected to gross, histopathological and histomorphometric evaluation. Graded exposure to PGEF resulted in increased serum concentration of T and decreased concentrations of FSH and LH, increased seminal plasma lipid peroxidation, seminiferous and epididymal tubular degeneration, germ cell depletion, lowered sperm concentration, decreased sperm motility and vitality, and increased sperm abnormal morphology. The close proximity between dogs and humans in exposed environments underscores the importance of these findings to human reproductive health and fertility. The findings suggest that with prolonged exposure, the impairment of reproductive functions will likely play significant roles in the decline in male fertility.


Subject(s)
Drug-Related Side Effects and Adverse Reactions , Testis , Adult , Male , Dogs , Humans , Animals , Vehicle Emissions/toxicity , Semen , Sperm Motility , Spermatozoa , Luteinizing Hormone , Follicle Stimulating Hormone , Testosterone , Sperm Count
2.
Cardiovasc Toxicol ; 21(12): 1019-1032, 2021 12.
Article in English | MEDLINE | ID: mdl-34533688

ABSTRACT

Exhaust fumes from petrol/diesel-powered electric generators contribute significantly to air pollution in many developing countries, constituting health hazards to both humans and animals. This study evaluated the serum concentrations of Troponin I (TnI), C-reactive protein (CRP) and serum levels/activities of oxidative stress markers: catalase (CAT), reduced glutathione (GSH), malondialdehyde (MDA), nitric oxide (NO) and superoxide dismutase (SOD) in dogs experimentally exposed to graded levels of petrol generator exhaust fume (PGEF). Sixteen (16) healthy and adult male Basenji dogs were randomly assigned into four groups (A-D). Group A was the unexposed control while groups B, C and D were exposed to PGEF for 1, 2 and 3 h per day, respectively, for 90 days. Repeated analysis were performed at the baseline, and every thirty days, for a total of 90 days. There was a significant interaction (p < 0.05) between the effects of PGEF exposure level (in h/day) and duration of exposure (in months) on all the tested serum parameters. There was a significant main effect (p < 0.05) for PGEF exposure level on the serum parameters. As the level of PGEF exposure was increased, the serum concentrations of TnI, CRP, CAT, MDA and NO increased, GSH decreased, whereas SOD activity increased by day 30 but declined at the end. Moreover, there was a significant simple main effect (p < 0.05) for duration of PGEF exposure. All the parameters increased as the duration of PGEF exposure was increased to 90 days except GSH concentration which decreased, whereas SOD activity increased initially but declined at the end of the study. Thus, there was increased serum concentrations of TnI, CRP and increased oxidative stress in the PGEF-exposed dogs. These findings are instructive and could be grounds for further studies on air pollutants-induced cardiovascular disease given the widespread use of electricity generators in many low-resource countries.


Subject(s)
Air Pollutants/toxicity , C-Reactive Protein/metabolism , Cardiovascular Diseases/chemically induced , Developing Countries , Electric Power Supplies/adverse effects , Gasoline/toxicity , Oxidative Stress/drug effects , Troponin I/blood , Animals , Biomarkers/blood , Cardiovascular Diseases/blood , Cardiovascular Diseases/physiopathology , Dogs , Heart Rate/drug effects , Inhalation Exposure , Male , Nigeria , Respiratory Rate/drug effects , Risk Assessment , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...