Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 1865-1868, 2021 11.
Article in English | MEDLINE | ID: mdl-34891651

ABSTRACT

Continuous non-invasive Blood Pressure (BP) monitoring is vital for the early detection and control of hypertension. However, this is yet not possible as all current non-invasive BP devices are cuff-based devices and hence precluding continuous monitoring. Several methods have been proposed to overcome this challenge, one of which utilises the Photoplethysmograph (PPG) signal in an effort to predict reliable BP values from this signal using various computational approaches. Although, good performance has been reported in the literature, it was mainly achieved on a small inadequate sample size using conventional models that are unable to account for the temporal variations in the input vector. To address these limitations, this paper proposes cuff-less and continuous blood pressure estimation using Long Short-term Memory (LSTM) and Gated Recurrent Units (GRU). The models were evaluated on 942 patients acquired from the Multiparameter Intelligent Monitoring in Intensive Care (MIMIC II) dataset. The proposed models produced superior results in comparison with conventional artificial neural network. In particular, the best performance was achieved by the GRU, with mean absolute error and standard deviation of 5.77 ± 8.52 mmHg and 3.33±5.02 mmHg for systolic (SBP) and diastolic blood pressure (DBP), respectively. Furthermore, the results comply with the international standards for cuff-less blood pressure estimation.


Subject(s)
Blood Pressure Determination , Hypertension , Blood Pressure , Humans , Hypertension/diagnosis , Neural Networks, Computer , Photoplethysmography
2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2020: 4269-4272, 2020 07.
Article in English | MEDLINE | ID: mdl-33018939

ABSTRACT

This paper proposes cuffless and continuous blood pressure estimation utilising Photoplethysmography (PPG) signals and state of the art recurrent network models, namely, Long Short Term Memory and Gated Recurrent Units. The models were validated on wide range of varying blood pressure and PPG signals acquired from the Multiparameter Intelligent Monitoring in Intensive Care database. Many features were extracted from the PPG waveform and several machine learning techniques were employed in an attempt to eliminate collinearity and reduce the size of input feature vector. Consequently, the most effective features for blood pressure estimation were selected. Experimental results show that the accuracy of the proposed methods outperform traditional models applied in the literature. The results satisfy the American National Standards of the Association for the Advancement of Medical Instrumentation.


Subject(s)
Blood Pressure Determination , Photoplethysmography , Animals , Blood Pressure , Machine Learning , Neural Networks, Computer
SELECTION OF CITATIONS
SEARCH DETAIL
...