Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Orthop Res Rev ; 16: 111-123, 2024.
Article in English | MEDLINE | ID: mdl-38741666

ABSTRACT

Purpose: Carpal tunnel syndrome (CTS) is a common condition characterized by compression of the median nerve (MN) within the carpal tunnel. Accurate diagnosis and assessment of CTS severity are crucial for appropriate management decisions. This study aimed to investigate the combined diagnostic utility of B-mode ultrasound (US) and shear wave elastography (SWE) for assessing the severity of CTS in comparison to electrodiagnostic tests (EDT). Materials and Methods: This prospective observational study was conducted over 9-month periods at a tertiary care hospital. A total of 48 patients (36 females, 12 males; mean age 44 ± 10.9 years; age range 28-57 years) with clinically suspected CTS were enrolled. All patients underwent EDT, US, and SWE. Based on the EDT results, CTS cases were categorized into four groups: mild, moderate, severe, and negative. The cross-sectional area (CSA) and elasticity (E) of the MN were measured at the tunnel inlet (CSAu and Eu) and pronator quadratus region (CSAo and Eo). The differences (CSAu-CSAo and Eu-Eo) were calculated. The primary outcomes were the diagnostic performance of CSAu, CSAu-CSAo, Eu, and Eu-Eo in differentiating moderate/severe from mild/negative CTS compared to EDT findings. Secondary outcomes included a correlation of US/SWE parameters with EDT grades and between each other. ANOVA, correlation, regression, and receiver operating characteristic (ROC) curve analyses were performed. Results: CSAu and CSAu-CSAo increased progressively with worsening CTS severity. E measurements were significantly higher in moderate-to-severe CTS compared to mild or negative cases. The combined metric of CSAu-CSAo at a 5 mm threshold exhibited enhanced performance, with a higher sensitivity (83.3%), specificity (100%), and area under the curve (AUC) (0.98), surpassing the results of CSAu when used independently. Similarly, the SWE measurements indicated that Eu-Eo at a 56.1kPa cutoff achieved an AUC of 0.95, with a sensitivity of 93.3% and specificity of 94.4%, outperforming the metrics for Eu when used alone, which had an AUC of 0.93, with identical sensitivity and specificity values (93.3% and 94.4%, respectively). Conclusion: The integration of ultrasound, shear wave elastography, and electrodiagnostic tests provides a comprehensive approach to evaluate anatomical and neurological changes and guide management decisions for CTS.

2.
Eur Radiol ; 33(2): 1286-1296, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35962816

ABSTRACT

OBJECTIVE: To assess the diagnostic accuracy and agreement of CT and MRI in terms of the Bosniak classification version 2019 (BCv2019). MATERIALS AND METHODS: A prospective multi-institutional study enrolled 63 patients with 67 complicated cystic renal masses (CRMs) discovered during ultrasound examination. All patients underwent CT and MRI scans and histopathology. Three radiologists independently assessed CRMs using BCv2019 and assigned Bosniak class to each CRM using CT and MRI. The final analysis included 60 histopathologically confirmed CRMs (41 were malignant and 19 were benign). RESULTS: Discordance between CT and MRI findings was noticed in 50% (30/60) CRMs when data were analyzed in terms of the Bosniak classes. Of these, 16 (53.3%) were malignant. Based on consensus reviewing, there was no difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT (87.8%; 95% CI = 73.8-95.9% versus 75.6%; 95% CI = 59.7-87.6%; p = 0.09, 84.2%; 95% CI = 60.4-96.6% versus 78.9%; 95% CI = 54.4-93.9%; p = 0.5, and 86.7%; 95% CI = 64.0-86.6% versus 76.7%; 95% CI = 75.4-94.1%; p = 0.1, respectively). The number and thickness of septa and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. The inter-reader agreement (IRA) was substantial for determining the Bosniak class in CT and MRI (k = 0.66; 95% CI = 0.54-0.76, k = 0.62; 95% CI = 0.50-0.73, respectively). The inter-modality agreement of the BCv219 between CT and MRI was moderate (κ = 0.58). CONCLUSION: In terms of BCv2019, CT and MRI are comparable in the classification of CRMs with no significant difference in diagnostic accuracy and reliability. KEY POINTS: • There is no significant difference in the sensitivity, specificity, and accuracy of the BCv2019 with MRI and BCv2019 with CT. • The number of septa and their thickness and the presence of enhanced nodules accounted for the majority of variations in Bosniak classes between CT and MRI. • The inter-reader agreement was substantial for determining the Bosniak class in CT and MRI and the inter-modality agreement of the BCv219 between CT and MRI was moderate.


Subject(s)
Kidney Diseases, Cystic , Kidney Neoplasms , Humans , Kidney Diseases, Cystic/diagnosis , Reproducibility of Results , Tomography, X-Ray Computed , Magnetic Resonance Imaging , Kidney/pathology , Retrospective Studies
3.
Eur J Radiol ; 117: 184-192, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31307646

ABSTRACT

PURPOSE: To assess diagnostic validity and reproducibility of Thyroid Imaging Reporting and Data System (TI-RADS) for interpretation of thyroid nodules by thyroid ultrasonography (US). METHOD: A prospective multicentre study initially included 557 patients with clinically suspected thyroid nodules. After exclusion, a final cohort of 380 patients with 948 thyroid nodules detected by US were enrolled. Based on American College of Radiology (ACR) TI-RADS, three radiologists analysed all US examinations independently and assigned a TI-RADS category to each thyroid nodule. The final diagnosis was based on cytology which was used as reference standard for calculating diagnostic performance of TI-RADS for predicting malignant thyroid nodules. The Fleiss and weighted kappa (κ) statistics were applied to assess inter-observer agreement of morphological features and TI-RADS scoring results for thyroid nodules. Additionally, we made a simple screening among referring clinicians to assess the clinical response to application of TI-RADS. RESULTS: A total of 948 thyroid nodules were evaluated; 136 (14.3%) were malignant, and 812 (85.7%) were benign. The papillary carcinoma was the most common malignant thyroid nodules (81.6%). The best cut-off value for predicting malignant thyroid nodules was > TR3. On a lesion-based analysis, the TI-RADS had a sensitivity, specificity, and an accuracy of 98.3%, 90.9%, and 92.1%, respectively when regarding those thyroid nodules classified as > TR3 for predicting malignancy. The inter-observer agreement of the TI-RADS category was good (κ = 0.636). Ninety percent of referring clinicians accept TI-RADS. CONCLUSIONS: TI-RADS improves diagnostic performance of US for predicting malignant thyroid nodules with high validity and high reproducibility.


Subject(s)
Data Systems , Radiology Information Systems , Thyroid Nodule/pathology , Adult , Aged , Female , Humans , Male , Middle Aged , Practice Guidelines as Topic , Prospective Studies , Reference Standards , Reproducibility of Results , Young Adult
4.
Eur Radiol ; 29(11): 5981-5990, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30993433

ABSTRACT

OBJECTIVE: To evaluate diagnostic performance and inter-reviewer agreement (IRA) of the Gynecologic Imaging Reporting and Data System (GI-RADS) for diagnosis of adnexal masses (AMs) by pelvic ultrasound (US). PATIENTS AND METHODS: A prospective multicenter study included 308 women (mean age, 41 ± 12.5 years; range, 15-73 years) with 325 AMs detected by US. All US examinations were analyzed, and AMs were categorized into five categories according to the GI-RADS classification. We used histopathology and US follow-up as the reference standards for calculating diagnostic performance of GI-RADS for detecting malignant AMs. The Fleiss kappa (κ) tests were applied to evaluate the IRA of GI-RADS scoring results for predicting malignant AMs. RESULTS: A total of 325 AMs were evaluated: 127 (39.1%) were malignant and 198 (60.9%) were benign. Of 95 AMs categorized as GI-RADS 2 (GR2), none was malignant; of 94 AMs categorized as GR3, three were malignant; of 13 AMs categorized as GR4, six were malignant; and of 123 AMs categorized as GR5, 118 were malignant. On a lesion-based analysis, the GI-RADS had a sensitivity, a specificity, and an accuracy of 92.9%, 97.5%, and 95.7%, respectively, when regarding only those AMs classified as GR5 for predicting malignancy. Considering combined GR4 and GR5 as a predictor for malignancy, the sensitivity, specificity, and accuracy of GI-RADS were 97.6%, 93.9%, and 95.4%, respectively. The IRA of the GI-RADS category was very good (κ = 0.896). The best cutoff value for predicting malignant AMs was >GR3. CONCLUSIONS: The GI-RADS is very valuable for improving US structural reports. KEY POINTS: • There is still a lack of a standard in the assessment of AMs. • GI-RADS is very valuable for improving US structural reports of AMs. • GI-RADS criteria are easy and work at least as well as IOTA.


Subject(s)
Adnexal Diseases/diagnostic imaging , Adolescent , Adult , Aged , Data Systems , Female , Gynecology , Humans , Middle Aged , Observer Variation , Ovarian Diseases/diagnostic imaging , Prospective Studies , Radiology Information Systems/standards , Reference Standards , Research Design , Sensitivity and Specificity , Ultrasonography , Young Adult
5.
Abdom Radiol (NY) ; 44(5): 1773-1784, 2019 05.
Article in English | MEDLINE | ID: mdl-30603882

ABSTRACT

PURPOSE: We investigated the added value of diffusion-weighted imaging (DWI)/apparent diffusion coefficient (ADC) in the categorization of small hepatic observation (≤ 20 mm) detected in patients with chronic liver disease in reference to LI-RADS (liver imaging reporting and data system) classification system. METHODS: We prospectively evaluated 165 patients with chronic liver disease with small hepatic observations (≤ 20 mm) which were previously categorized as LI-RADS grade 3-5 on dynamic contrast-enhanced CT (DCE-CT). All patients were submitted to a functional MRI including DCE and DWI. Using LI-RADS v2017, two radiologists independently evaluated the observations and assigned a LI-RADS category to each observation using DCE-MRI alone and combined DCE-MRI and DWI/ADC. In the combined technique, the radiologists assigned a LI-RADS category based on a modified LI-RADS criteria in which restricted diffusion on DWI was considered a major feature of HCC. We evaluated the inter-reader agreement with Kappa statistics and compared the diagnostic performance of the LI-RADS with two imaging techniques by Fisher's exact test using histopathology as the reference standard. RESULTS: Combined technique in LI-RADS yielded better sensitivities (reader 1, 97% [65/67]; reader 2, 95.5% [64/67]) for HCC diagnosis than DCE-MRI alone (reader 1, 80.6% [54/67], p = 0.005; reader 2, 83.6% [56/67], p = 0.04). The specificities were insignificantly lower in combined technique (reader 1, 88.4% [107/121]; reader 2, 77.7% [94/121]) than in DCE-MRI alone (reader 1, 90.9% [110/121], p = 0.67; reader 2, 79.3% [96/121], p = 0.88). The inter-reader agreement of the LI-RADS scores between combined technique and DCE-MRI was good (κ = 0.765). CONCLUSION: The use of DWI/ADC as an additional major criterion, improved the sensitivity of LI-RADS in the diagnosis of HCC while keeping high specificity.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Liver Neoplasms/diagnostic imaging , Adult , Aged , Contrast Media , Female , Humans , Liver Neoplasms/pathology , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...