Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anaesthesia ; 54(12): 1161-5, 1999 12.
Article in English | MEDLINE | ID: mdl-10594413

ABSTRACT

In a prospective, randomised trial, 75 patients scheduled for routine surgery were randomly allocated to one of three groups to evaluate trauma and postoperative complications after insertion of the Combitube, tracheal tube or laryngeal mask airway. Insertion of the Combitube was associated with a higher incidence of sore throat (48% vs. 16% vs. 12% [p < 0.01]) and dysphagia (68% vs. 12% vs. 8% [p < 0.01]) compared with tracheal intubation or insertion of the laryngeal mask airway, respectively. Hoarseness was significantly less common in both the Combitube and the laryngeal mask groups (both 12%) than in the tracheal tube group (44%; p < 0.01). Haematoma occurred in 36% of the Combitube group compared with 4% in both the laryngeal mask and the tracheal tube groups (p < 0.01). The higher incidence of complications should be considered when using the Combitube.


Subject(s)
Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/instrumentation , Adult , Aged , Deglutition Disorders/etiology , Female , Hematoma/etiology , Hoarseness/etiology , Humans , Laryngeal Masks/adverse effects , Male , Middle Aged , Pharyngitis/etiology , Prospective Studies , Tracheal Diseases/etiology
2.
Anesth Analg ; 88(6): 1389-94, 1999 06.
Article in English | MEDLINE | ID: mdl-10357350

ABSTRACT

UNLABELLED: In a prospective, randomized, and controlled trial, we compared the stress responses after insertion of the Combitube (CT; Kendall-Sheridan Catheter Corp., Argyle, NY), the laryngeal mask airway (LMA), or endotracheal intubation (ET). Seventy-five patients scheduled for routine urological or gynecological surgery were randomly allocated to one of three groups and were ventilated via either an ET, a LMA, or a CT. All three devices could be inserted easily and rapidly, providing adequate ventilation and oxygenation. Insertion of the CT was associated with a significant increase in mean maximal systolic arterial pressure (160+/-32 mm Hg) and diastolic arterial pressure (91+/-17 mm Hg) compared with ET (140+/-24, 78+/-11 mm Hg; P < 0.05, P < 0.01, respectively) or insertion of the LMA (115+/-33,63+/-22 mm Hg, both P < 0.001). The mean maximal epinephrine and norepinephrine plasma concentrations after insertion of the CT (37.3+/-31.1 and 279+/-139 pg/mL, respectively) were significantly higher than those after ET (35.8+/-89.8 and 195+/-58 pg/mL, respectively) or insertion of a LMA (17.3+/-13.3 and 158+/-67 pg/mL, respectively). This might be attributed to the pressure of the pharyngeal cuff of the CT on the anterior pharyngeal wall. We conclude that insertion of the CT causes a pronounced stress response and that precautions should be taken when used in patients at risk of hypertensive bleeding. IMPLICATIONS: In this study, we showed that the hemodynamic and catecholamine stress responses after insertion of the Combitube (Kendall-Sheridan Catheter Corp., Argyle, NY) were significantly higher compared with laryngeal mask airway or endotracheal intubation. We conclude that the increased stress response to insertion of a Combitube may represent a serious hazard to patients with cardiovascular disease.


Subject(s)
Catecholamines/blood , Hemodynamics , Intubation, Intratracheal/adverse effects , Laryngeal Masks/adverse effects , Stress, Physiological/physiopathology , Adult , Epinephrine/blood , Female , Humans , Male , Middle Aged , Norepinephrine/blood , Prospective Studies , Stress, Physiological/blood , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...