Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
Europace ; 24(10): 1627-1635, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35718878

ABSTRACT

AIMS: The GermAn Laser Lead Extraction RegistrY: GALLERY is a retrospective, national multicentre registry, investigating the safety and efficacy of laser lead extraction procedures in Germany. METHODS AND RESULTS: Twenty-four German centres that are performing laser lead extraction have participated in the registry. All patients, treated with a laser lead extraction procedure between January 2013 and March 2017, were consecutively enrolled. Safety and efficacy of laser lead extraction were investigated. A total number of 2524 consecutive patients with 6117 leads were included into the registry. 5499 leads with a median lead dwell time of 96 (62-141) months were treated. The mean number of treated leads per patient was 2.18 ± 1.02. The clinical procedural success rate was 97.86% and the complete lead removal was observed in 94.85%. Additional extraction tools were used in 6.65% of cases. The rate of procedural failure was 2.14% with lead age ≥10 years being its only predictor. The overall complication rate was 4.32%, including 2.06% major and 2.26% minor complications. Procedure-related mortality was 0.55%. Female sex and the presence of abandoned leads were predictors for procedure-related complications. The all-cause in-hospital mortality was 3.56% with systemic infection being the strongest predictor, followed by age ≥75 years and chronic kidney disease. CONCLUSION: In the GALLERY, a high success- and low procedure-related complication rates have been demonstrated. In multivariate analysis, female sex and the presence of abandoned leads were predictors for procedure-related complications, while the presence of systemic infection, age ≥75 years, and chronic kidney disease were independent predictors for all-cause mortality.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Renal Insufficiency, Chronic , Aged , Child , Defibrillators, Implantable/adverse effects , Device Removal/methods , Female , Humans , Lasers, Excimer , Pacemaker, Artificial/adverse effects , Postoperative Complications/etiology , Registries , Retrospective Studies , Treatment Outcome
3.
Herzschrittmacherther Elektrophysiol ; 24(3): 189-90, 2013 Sep.
Article in German | MEDLINE | ID: mdl-23764773

ABSTRACT

A case of pacemaker electrode infection with Staphylococcus aureus is presented. In order to avoid sternotomy, the right ventricular pacemaker lead, which had been implanted for 15 years, was successfully extracted using a laser sheath despite large endocarditic vegetations on the pacemaker lead. After completion of a 6-week course of antibiotics, the patient was discharged without any further evidence of infection.


Subject(s)
Device Removal/instrumentation , Device Removal/methods , Electrodes, Implanted/adverse effects , Laser Therapy/methods , Pacemaker, Artificial/adverse effects , Prosthesis-Related Infections/etiology , Prosthesis-Related Infections/surgery , Aged , Humans , Male , Prosthesis-Related Infections/diagnosis , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...