Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 11(10): e0165530, 2016.
Article in English | MEDLINE | ID: mdl-27788264

ABSTRACT

Real-time on-site histopathology review of biopsy tissues at the point-of-procedure has great potential for significant clinical value and improved patient care. For instance, on-site review can aid in rapid screening of diagnostic biopsies to reduce false-negative results, or in quantitative assessment of biospecimen quality to increase the efficacy of downstream laboratory and histopathology analysis. However, the only currently available rapid pathology method, frozen section analysis (FSA), is too time- and labor-intensive for use in screening large quantities of biopsy tissues and is too destructive for maximum tissue conservation in multiple small needle core biopsies. In this work we demonstrate the spectrally-compatible combination of the nuclear stain DRAQ5 and the anionic counterstain eosin as a dual-component fluorescent staining analog to hematoxylin and eosin intended for use on fresh, unsectioned tissues. Combined with optical sectioning fluorescence microscopy and pseudo-coloring algorithms, DRAQ5 and eosin ("D&E") enables very fast, non-destructive psuedohistological imaging of tissues at the point-of-acquisition with minimal tissue handling and processing. D&E was validated against H&E on a one-to-one basis on formalin-fixed paraffin-embedded and frozen section tissues of various human organs using standard epi-fluorescence microscopy, demonstrating high fidelity of the staining mechanism as an H&E analog. The method was then applied to fresh, whole 18G renal needle core biopsies and large needle core prostate biospecimen biopsies using fluorescence structured illumination optical sectioning microscopy. We demonstrate the ability to obtain high-resolution histology-like images of unsectioned, fresh tissues similar to subsequent H&E staining of the tissue. The application of D&E does not interfere with subsequent standard-of-care H&E staining and imaging, preserving the integrity of the tissue for thorough downstream analysis. These results indicate that this dual-stain pseudocoloring method could provide a real-time histology-like image at the time of acquisition and valuable objective tissue analysis for the clinician at the time of service.


Subject(s)
Anthraquinones/pharmacology , Eosine Yellowish-(YS)/chemistry , Eosine Yellowish-(YS)/pharmacology , Hematoxylin/chemistry , Biopsy , Fluorescence , Humans
2.
Urology ; 98: 195-199, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27597632

ABSTRACT

OBJECTIVE: To present a novel imaging technique used for rapid, nondestructive histological assessment of renal neoplasias using a dual-component fluorescence stain and structured illumination microscopy (SIM). MATERIALS AND METHODS: After Institutional Review Board approval, 65 total biopsies were obtained from 19 patients undergoing partial or radical nephrectomy. Biopsies were stained with a dual-component fluorescent, and optically sectioned SIM images were obtained from the surface of the intact biopsies. Specimens were subsequently fixed and analyzed using hematoxylin and eosin (H&E) histopathologic methods and compared with SIM images. A single, board-certified pathologist blinded to specimens reviewed all SIM images and H&E slides, and determined the presence or absence of neoplasias. Results of blinded diagnosis of SIM were validated against traditional pathology. RESULTS: Of the 19 patients, 15 underwent robotic partial nephrectomies and 4 underwent laparoscopic nephrectomies. Indications included clinical suspicion of renal cell carcinoma. In total, 65 biopsy specimens were available for review. Twenty-one specimens were determined to be neoplastic on H&E, whereas 41 represented benign renal tissue. The final sensitivity and specificity of our study were 79.2% and 95.1%, respectively. CONCLUSION: SIM is a promising technology for rapid, near-patient, ex vivo renal biopsy assessment. By improving the ability to rapidly assess sufficiency of biopsy specimens and enabling immediate diagnostic capability, SIM aids in more effective biopsy performance, tissue triage, and patient counseling regarding management options. Additionally, because tissue is preserved, effective utilization of downstream diagnostic tests and molecular assessments are possible.


Subject(s)
Biopsy, Large-Core Needle/methods , Carcinoma, Renal Cell/diagnosis , Kidney Neoplasms/diagnosis , Kidney/pathology , Microscopy, Fluorescence/methods , Adult , Diagnosis, Differential , Equipment Design , Female , Humans , Male , Middle Aged
3.
Sci Rep ; 6: 27419, 2016 06 03.
Article in English | MEDLINE | ID: mdl-27257084

ABSTRACT

Achieving cancer-free surgical margins in oncologic surgery is critical to reduce the need for additional adjuvant treatments and minimize tumor recurrence; however, there is a delicate balance between completeness of tumor removal and preservation of adjacent tissues critical for normal post-operative function. We sought to establish the feasibility of video-rate structured illumination microscopy (VR-SIM) of the intact removed tumor surface as a practical and non-destructive alternative to intra-operative frozen section pathology, using prostate cancer as an initial target. We present the first images of the intact human prostate surface obtained with pathologically-relevant contrast and subcellular detail, obtained in 24 radical prostatectomy specimens immediately after excision. We demonstrate that it is feasible to routinely image the full prostate circumference, generating gigapixel panorama images of the surface that are readily interpreted by pathologists. VR-SIM confirmed detection of positive surgical margins in 3 out of 4 prostates with pathology-confirmed adenocarcinoma at the circumferential surgical margin, and furthermore detected extensive residual cancer at the circumferential margin in a case post-operatively classified by histopathology as having negative surgical margins. Our results suggest that the increased surface coverage of VR-SIM could also provide added value for detection and characterization of positive surgical margins over traditional histopathology.


Subject(s)
Prostate/pathology , Prostatic Neoplasms/pathology , Adenocarcinoma/pathology , Frozen Sections/methods , Humans , Lighting/methods , Male , Margins of Excision , Microscopy/methods , Microscopy, Video/methods , Neoplasm Recurrence, Local/pathology , Prostatectomy/methods
4.
Cancer Res ; 75(19): 4032-41, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26282168

ABSTRACT

Rapid assessment of prostate core biopsy pathology at the point-of-procedure could provide benefit in a variety of clinical situations. Even with advanced transrectal ultrasound guidance and saturation biopsy protocols, prostate cancer can be missed in up to half of all initial biopsy procedures. In addition, collection of tumor specimens for downstream histologic, molecular, and genetic analysis is hindered by low tumor yield due to inability to identify prostate cancer grossly. However, current point-of-procedure pathology protocols, such as frozen section analysis (FSA), are destructive and too time- and labor-intensive to be practical or economical. Ex vivo microscopy of the excised specimens, stained with fast-acting fluorescent histology dyes, could be an attractive nondestructive alternative to FSA. In this work, we report the first demonstration of video-rate structured illumination microscopy (VR-SIM) for rapid high-resolution diagnostic imaging of prostate biopsies in realistic point-of-procedure timeframes. Large mosaic images of prostate biopsies stained with acridine orange are rendered in seconds and contain excellent contrast and detail, exhibiting close correlation with corresponding hematoxylin and eosin histology. A clinically relevant review of VR-SIM images of 34 unfixed and uncut prostate core biopsies by two independent pathologists resulted in an area under the receiver operative curve (AUC) of 0.82-0.88, with a sensitivity ranging from 63% to 88% and a specificity ranging from 78% to 89%. When biopsies contained more than 5% tumor content, the sensitivity improved to 75% to 92%. The image quality, speed, minimal complexity, and ease of use of VR-SIM could prove to be features in favor of adoption as an alternative to destructive pathology at the point-of-procedure.


Subject(s)
Adenocarcinoma/diagnosis , Biopsy, Needle/methods , Imaging, Three-Dimensional/methods , Microscopy, Fluorescence/methods , Microscopy, Video/methods , Prostate/pathology , Prostatic Neoplasms/diagnosis , Acridine Orange , Adenocarcinoma/pathology , Area Under Curve , Coloring Agents , Humans , Imaging, Three-Dimensional/instrumentation , Male , Microscopy, Fluorescence/instrumentation , Microscopy, Video/instrumentation , Observer Variation , Point-of-Care Systems , Predictive Value of Tests , Prostatectomy , Prostatic Intraepithelial Neoplasia/diagnosis , Prostatic Intraepithelial Neoplasia/pathology , Prostatic Neoplasms/pathology , ROC Curve , Sensitivity and Specificity , Single-Blind Method , Time Factors
5.
J Biomed Opt ; 19(10): 107001, 2014.
Article in English | MEDLINE | ID: mdl-25321401

ABSTRACT

Reduction of warm ischemia time during partial nephrectomy (PN) is critical to minimizing ischemic damage and improving postoperative kidney function, while maintaining tumor resection efficacy. Recently, methods for localizing the effects of warm ischemia to the region of the tumor via selective clamping of higher-order segmental artery branches have been shown to have superior outcomes compared with clamping the main renal artery. However, artery identification can prolong operative time and increase the blood loss and reduce the positive effects of selective ischemia. Quantitative diffuse reflectance spectroscopy (DRS) can provide a convenient, real-time means to aid in artery identification during laparoscopic PN. The feasibility of quantitative DRS for real-time longitudinal measurement of tissue perfusion and vascular oxygenation in laparoscopic nephrectomy was investigated in vivo in six Yorkshire swine kidneys (n=three animals ). DRS allowed for rapid identification of ischemic areas after selective vessel occlusion. In addition, the rates of ischemia induction and recovery were compared for main renal artery versus tertiary segmental artery occlusion, and it was found that the tertiary segmental artery occlusion trends toward faster recovery after ischemia, which suggests a potential benefit of selective ischemia. Quantitative DRS could provide a convenient and fast tool for artery identification and evaluation of the depth, spatial extent, and duration of selective tissue ischemia in laparoscopic PN.


Subject(s)
Ischemia/classification , Laparoscopy/adverse effects , Laparoscopy/methods , Nephrectomy/methods , Optical Imaging/methods , Spectrum Analysis/methods , Animals , Feasibility Studies , Hemoglobins/analysis , Ischemia/blood , Ischemia/physiopathology , Kidney/blood supply , Kidney/surgery , Kidney Diseases/surgery , Nephrectomy/adverse effects , Renal Artery/surgery , Swine
6.
Biomed Opt Express ; 5(2): 366-77, 2014 Feb 01.
Article in English | MEDLINE | ID: mdl-24575333

ABSTRACT

We report the development of a structured illumination microscopy instrument specifically designed for the requirements for high-area-throughput, optically-sectioned imaging of large, fluorescently-stained tissue specimens. The system achieves optical sectioning frame-rates of up to 33 Hz (and pixel sampling rates of up to 138.4 MHz), by combining a fast, ferroelectric spatial light modulator for pattern generation with the latest large-format, high frame-rate scientific CMOS camera technology. Using a 10X 0.45 NA objective and a 7 mm/sec scan stage, we demonstrate 4.4 cm(2)/min area-throughput rates in bright tissue-simulating phantoms, and 2 cm(2)/min area-throughput rates in thick, highly-absorbing, fluorescently-stained muscle tissue, with 1.3 µm lateral resolution. We demonstrate high-contrast, high-resolution imaging of a fluorescently-stained 30.4 cm(2) bovine muscle specimen in 15 minutes comprising 7.55 gigapixels, demonstrating the feasibility of the approach for gigapixel imaging of large tissues in short timeframes, such as would be needed for intraoperative imaging of tumor resection specimens.

SELECTION OF CITATIONS
SEARCH DETAIL
...