Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
JMIR Hum Factors ; 9(2): e26825, 2022 Apr 01.
Article in English | MEDLINE | ID: mdl-35363150

ABSTRACT

BACKGROUND: Instrumented assessment of motor symptoms has emerged as a promising extension to the clinical assessment of several movement disorders. The use of mobile and inexpensive technologies such as some markerless motion capture technologies is especially promising for large-scale application but has not transitioned into clinical routine to date. A crucial step on this path is to implement standardized, clinically applicable tools that identify and control for quality concerns. OBJECTIVE: The main goal of this study comprises the development of a systematic quality control (QC) procedure for data collected with markerless motion capture technology and its experimental implementation to identify specific quality concerns and thereby rate the usability of recordings. METHODS: We developed a post hoc QC pipeline that was evaluated using a large set of short motor task recordings of healthy controls (2010 recordings from 162 subjects) and people with multiple sclerosis (2682 recordings from 187 subjects). For each of these recordings, 2 raters independently applied the pipeline. They provided overall usability decisions and identified technical and performance-related quality concerns, which yielded respective proportions of their occurrence as a main result. RESULTS: The approach developed here has proven user-friendly and applicable on a large scale. Raters' decisions on recording usability were concordant in 71.5%-92.3% of cases, depending on the motor task. Furthermore, 39.6%-85.1% of recordings were concordantly rated as being of satisfactory quality whereas in 5.0%-26.3%, both raters agreed to discard the recording. CONCLUSIONS: We present a QC pipeline that seems feasible and useful for instant quality screening in the clinical setting. Results confirm the need of QC despite using standard test setups, testing protocols, and operator training for the employed system and by extension, for other task-based motor assessment technologies. Results of the QC process can be used to clean existing data sets, optimize quality assurance measures, as well as foster the development of automated QC approaches and therefore improve the overall reliability of kinematic data sets.

2.
EPMA J ; 12(1): 91-101, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33782636

ABSTRACT

BACKGROUND: Quantification of motor performance has a promising role in personalized medicine by diagnosing and monitoring, e.g. neurodegenerative diseases or health problems related to aging. New motion assessment technologies can evolve into patient-centered eHealth applications on a global scale to support personalized healthcare as well as treatment of disease. However, uncertainty remains on the limits of generalizability of such data, which is relevant specifically for preventive or predictive applications, using normative datasets to screen for incipient disease manifestations or indicators of individual risks. OBJECTIVE: This study explored differences between healthy German and Japanese adults in the performance of a short set of six motor tests. METHODS: Six motor tasks related to gait and balance were recorded with a validated 3D camera system. Twenty-five healthy adults from Chiba, Japan, participated in this study and were matched for age, sex, and BMI to a sample of 25 healthy adults from Berlin, Germany. Recordings used the same technical setup and standard instructions and were supervised by the same experienced operator. Differences in motor performance were analyzed using multiple linear regressions models, adjusted for differences in body stature. RESULTS: From 23 presented parameters, five showed group-related differences after adjustment for height and weight (R 2 between .19 and .46, p<.05). Japanese adults transitioned faster between sitting and standing and used a smaller range of hand motion. In stepping-in-place, cadence was similar in both groups, but Japanese adults showed higher knee movement amplitudes. Body height was identified as relevant confounder (standardized beta >.5) for performance of short comfortable and maximum speed walks. For results of posturography, regression models did not reveal effects of group or body stature. CONCLUSIONS: Our results support the existence of a population-specific bias in motor function patterns in young healthy adults. This needs to be considered when motor function is assessed and used for clinical decisions, especially for personalized predictive and preventive medical purposes. The bias affected only the performance of specific items and parameters and is not fully explained by population-specific ethnic differences in body stature. It may be partially explained as cultural bias related to motor habits. Observed effects were small but are expected to be larger in a non-controlled cross-cultural application of motion assessment technologies with relevance for related algorithms that are being developed and used for data processing. In sum, the interpretation of individual data should be related to appropriate population-specific or even better personalized normative values to yield its full potential and avoid misinterpretation. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s13167-021-00236-3.

3.
Sensors (Basel) ; 20(19)2020 Sep 23.
Article in English | MEDLINE | ID: mdl-32977647

ABSTRACT

Fluctuations of motor symptoms make clinical assessment in Parkinson's disease a complex task. New technologies aim to quantify motor symptoms, and their remote application holds potential for a closer monitoring of treatment effects. The focus of this study was to explore the potential of a stepping in place task using RGB-Depth (RGBD) camera technology to assess motor symptoms of people with Parkinson's disease. In total, 25 persons performed a 40 s stepping in place task in front of a single RGBD camera (Kinect for Xbox One) in up to two different therapeutic states. Eight kinematic parameters were derived from knee movements to describe features of hypokinesia, asymmetry, and arrhythmicity of stepping. To explore their potential clinical utility, these parameters were analyzed for their Spearman's Rho rank correlation to clinical ratings, and for intraindividual changes between treatment conditions using standard response mean and paired t-test. Test performance not only differed between ON and OFF treatment conditions, but showed moderate correlations to clinical ratings, specifically ratings of postural instability (pull test). Furthermore, the test elicited freezing in some subjects. Results suggest that this single standardized motor task is a promising candidate to assess an array of relevant motor symptoms of Parkinson's disease. The simple technical test setup would allow future use by patients themselves.


Subject(s)
Movement , Parkinson Disease , Biomechanical Phenomena , Female , Humans , Hypokinesia , Male , Parkinson Disease/diagnosis , Video Recording
4.
Mov Disord Clin Pract ; 3(6): 587-595, 2016.
Article in English | MEDLINE | ID: mdl-30363467

ABSTRACT

BACKGROUND: Reviewers of dystonia rating scales agree on the need to assess symptoms more comprehensively. During the development of a quantitative dystonia assessment by video-perceptive computing, we devised a video-based severity ranking as a procedure to create a validation standard without the use of clinical scales. METHODS: Thirty-four patients with dystonia (17 with dystonic tremor) and 2 controls were assessed with clinical scales and video-recordings of 24 short movement tasks. Two to 4 raters compared multiple permutations of videos from 22 subjects, including 2 healthy controls, until a complete rank order was achieved. Inter-rater agreement was expressed as normalized Kendall tau distance. Spearman correlations of video rank order with clinical scales and self-rating were repeated for tremor/nontremor subgroups. RESULTS: Normalized Kendall tau distances were <0.3 for 15 items. The video rank order for sitting and head movements correlated with clinical scales for the whole group (rho 0.52-0.87) and in the subgroup without tremor. In the tremor subgroup such correlation was perceived in the 2 items involving sitting. Video rank order correlated with quality of life self-rating only in 1 item (arms held in front, palm down). CONCLUSIONS: The agreement of video rankings between raters is remarkable. The lack of correlation in the tremor subgroup in several items may be interpreted as tremor being considered in video comparisons but not in clinical scales. This supports video-based ranking as a more comprehensive rating of dystonia and as a possible validation instrument applicable in situations in which no reference standard is available.

SELECTION OF CITATIONS
SEARCH DETAIL
...