Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Orthop Rev (Pavia) ; 16: 88396, 2024.
Article in English | MEDLINE | ID: mdl-38765296

ABSTRACT

Background: One of complications of the reverse shoulder arthroplasty is acromion fractures, and its therapy is controversial. The aim of the study was to investigate the double-plate osteosynthesis for these fractures. Methods: An acromion type III fracture according to classification of Levy was simulated in 16 human shoulder cadavers, and the specimens were randomly divided into two groups. Single-plate osteosynthesis was performed in the first group (locking compression plate) and double-plate osteosynthesis (locking compression plate and one-third tubular locking plate) in the second group. Biomechanical testing included cycling load and load at failure on a material testing machine. During the test, the translation was measured using an optical tracking system. Results: The load at failure for the single-plate osteosynthesis was 167 N and for the double-osteosynthesis 233.7 N (P = 0.328). The average translation was 11.1 mm for the single-plate osteosynthesis and 16.4 mm for the double-plate osteosynthesis (P = 0.753). The resulting stiffness resulted in 74.7 N/mm for the single-plate osteosynthesis and 327.9 N/mm for the double-plate osteosynthesis (P = 0.141). Discussion: Results of the biomechanical study showed that double-plate osteosynthesis had biomechanical properties similar to those of single-plate osteosynthesis for an acromion type III fracture at time point zero. The missing advantages of double-plate osteosynthesis can be explained by the choice of plate configuration.

2.
Article in English | MEDLINE | ID: mdl-38750111

ABSTRACT

PURPOSE: The influence of the subscapularis tendon on reverse total shoulder arthroplasty (RTSA) has been discussed controversially. The aim of the study was to investigate the subscapularis-sparing approach for RTSA and the effect of the intact subscapularis tendon. METHODS: This retrospective comparative study included 93 patients. Among these, 55 underwent the deltopectoral subscapularis-sparing approach, and in 38 cases, the standard deltopectoral approach with subscapularis tenotomy was applied. At the final follow-up, representative shoulder scores were measured, radiographs were taken in two planes, and shoulder sonography was performed. RESULTS: The subscapularis-sparing group showed a significantly higher Constant score (71.8 vs. 65.9 points) and adapted Constant score if the subscapularis tendon was shown to be intact in the postoperative sonography (85.2% vs. 78.6%) (p = 0.005; p = 0.041). Furthermore, these patients had improved abduction (128.2 vs. 116.8, p = 0.009) and external rotation (34.6 vs. 27.1, p = 0.047). However, no significant differences were found for the degree of internal rotation and internal rotation strength. No dislocation or infection was observed. The degree of scapular notching was not significantly different between the two groups (p = 0.082). However, independently from the integrity of the subscapularis the subscapularis-sparing approach showed no difference in clinical and radiographic outcome (Constant score scapularis-sparing 70.0 points vs. tenotomy 66.8 points; p = 0.27). CONCLUSION: The subscapularis-sparing approach RTSA showed improved clinical outcome, abduction, and external rotation, if the subscapularis was shown to be intact at time of follow-up. Both groups showed no difference in internal rotation.

3.
Eur J Orthop Surg Traumatol ; 34(3): 1441-1448, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38240825

ABSTRACT

INTRODUCTION: The purpose of this prospective study was to examine clinical results of tuberosity refixation in RSA for the treatment of displaced PHF in elderly patients. We hypothesized that tuberosity refixation would increase clinical outcome. METHODS: In this prospective study, 50 patients were included after receive a primary RSA for complex proximal humeral fracture between March 2013 and December 2015 for follow-up after three, 12 and 24 months. A functional and radiological assessment was performed on the patients. RESULTS: At final follow-up after a mean period of 25.1 months, data were available for 30 women and 6 men (74% of the included overall study collective) with a mean age of 77 years (range 55-93 years) at time of surgery. The tuberosities were refixated in 74% (n = 37) and in 26% (n = 13) resected. RSA with tuberosity refixation resulted in better clinical shoulder function compared to RSA with non-refixated tuberosities. The data show an external rotation with a significant difference (24.9° vs. 14°, p < 0.05) in favor of participants with refixation. The raw CMS was statistically significant (71.3 vs. 56.3, p < 0.05) after refixation, and SSV was significant improved (82.7% vs. 68%, p < 0.05) in the same group. Among 3 of 50 patients a total of 3 complications occurred with a total of 6% surgical revision. CONCLUSIONS: In this prospective study, tuberosity refixation as part of fracture treatment using RSA results in better external rotation, subjective assessment of shoulder recovery (measured by SSV and by raw CMS) in elderly patients, compared with tuberosity excision. LEVEL OF EVIDENCE: II, Prospective comparative study.


Subject(s)
Arthroplasty, Replacement, Shoulder , Shoulder Fractures , Shoulder Joint , Male , Humans , Female , Aged , Middle Aged , Aged, 80 and over , Arthroplasty, Replacement, Shoulder/methods , Prospective Studies , Treatment Outcome , Reoperation , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Range of Motion, Articular , Shoulder Joint/diagnostic imaging , Shoulder Joint/surgery , Retrospective Studies
4.
Eur J Orthop Surg Traumatol ; 33(6): 2533-2540, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36596884

ABSTRACT

INTRODUCTION: Despite ongoing discussions for the previous few decades, there is still no consensus regarding the optimal surgical technique for acromioclavicular joint instabilities. The purpose of this study was to determine the impact of various implant materials following arthroscopically assisted stabilization of acromioclavicular joint instabilities on tunnel widening and implant migration. We hypothesized an implant-dependent behavior for tunnel widening and implant migration with differences when comparing acute and chronic acromioclavicular joint instabilities. METHODS: This study compared 105 patients with acromioclavicular joint instabilities that were managed operatively with coracoclavicular double button constructs. Two of the groups containing acute cases were treated with either a double button construct with a wire (TR) or a tape (D) as a central pillar. The two groups with chronic cases were either treated with a wire (T+) or tape D+ as a central pillar and additional hamstring tendon augmentation (+). One central transclavicular-transcoracoidal drill channel was made in the acute cases, while additional medial and lateral drill channels to augment the central pillar with the hamstring tendon were made. The central drill channel in all cases and the medial/lateral drill channels in chronic cases were subsequently radiologically analyzed immediately postoperatively and at follow-up. Following this, additional radiological analysis of the implant migration of the clavicular button took place. RESULTS: All groups showed significant tunnel widening of the central drill channel at follow-up (p ≤ 0.001). The TR+ technique demonstrated significant widening in both the medial (p ≤ 0.001) and lateral (p ≤ 0.001) drill channels. The D and D+ group displayed significant higher rates of clavicular button migration to a cortical and intraosseous level (p ≤ 0.002). CONCLUSION: Tunnel widening and implant migration following arthroscopically assisted management of acromioclavicular joint instabilities are dependent on the chosen implant. The stable tape showed a significantly increased degree of tunnel widening with respect to the central drill channel in comparison with the wire. In contrast, a higher degree of load capacity of the tape ultimately favors a protected intraosseous graft healing for chronic cases, which leads to less tunnel widening of the medial and lateral drill channel. Finally, the D/D+ implant groups showed higher rates of implant migration due to lower contact surface area of the implant at the upper clavicular cortex.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Joint Instability , Humans , Acromioclavicular Joint/surgery , Arthroscopy/adverse effects , Arthroscopy/methods , Joint Instability/etiology , Joint Instability/surgery , Joint Instability/diagnostic imaging , Prostheses and Implants , Radiography , Joint Dislocations/surgery
5.
Eur J Orthop Surg Traumatol ; 33(4): 1185-1192, 2023 May.
Article in English | MEDLINE | ID: mdl-35523973

ABSTRACT

PURPOSE: Purpose of this study was to demonstrate that a single tunnel reconstruction of high-grade acromioclavicular (AC) joint instabilities with implants of the second generation is sufficient for stabilisation, especially in combination with an AC cerclage. METHODS: Patients with an acute AC-joint dislocation type Rockwood III-B and V were included. Besides clinical follow-up examination, radiographs were analysed. The functional outcome measures were Constant Score (CS), Taft score (TS), ACJI score and patient's satisfaction. Horizontal instability was evaluated by clinical examination and radiological with an Alexander view. RESULTS: Thirty-five patients with a mean follow-up of 29 months were included. Ninety-seven per cent were satisfied with their result, with an average Subjective Shoulder Value of 90%. The CS averaged at 90 ± 10 points, TS at 11 ± 1 points and ACJI at 78 ± 18 points. Radiologically, 3 of 29 patients (10%) showed a persisting horizontal instability. The coracoclavicular (CC) distance improved from 22 preoperative to 10 mm postoperative, which was comparable to the contralateral side (10 mm, p = 0.103). At follow-up the CC distance increased to 13 mm (p = 0.0001). CONCLUSION: AC-joint stabilisation with a single tunnel reconstruction using a second-generation implant results in good to excellent clinical results with high patient satisfaction. The additional AC augmentation improves stability in horizontal instable AC-joints and is recommended in all high-grade AC joint stabilisations. Nonetheless, reduction was slightly lost over time due to an elongation or suture failure of the coraco-clavicular fixation. LEVEL OF EVIDENCE: IV.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Joint Instability , Shoulder Dislocation , Humans , Acromioclavicular Joint/surgery , Treatment Outcome , Arthroscopy/methods , Shoulder Dislocation/surgery , Joint Instability/surgery , Joint Dislocations/surgery , Ligaments, Articular
6.
Eur J Orthop Surg Traumatol ; 33(4): 1307-1314, 2023 May.
Article in English | MEDLINE | ID: mdl-35622161

ABSTRACT

PURPOSE: The aim of this study was to analyse and compare the 24-month range of motion results of patients treated with CFR-PEEK2 versus conventional titanium plate osteosyntheses (TAL-P). We hypothesized similar clinical outcomes but a better range of motion in the CFR-PEEK2 group than the TAL-P group in the 2-year follow-up. METHODS: This retrospective study analysing prospectively collected data included all patients that presented with a PHF and were treated with CFR-PEEK2 between November 2016 and April 2018. Follow-up was performed after a minimum of 24 months, evaluating the functional degree of movement functional scores, including the Subjective Shoulder Value (SSV) as well as an age- and sex-adapted Constant-Murley score (CMS). The 2-year results were compared to the results of a matched pair group comprising patients that were treated with TAL-P during the same period. RESULTS: Of the 35 patients included (mean age: 61.2 [18-78] years), 30 (86%) patients completed the 24-month follow-up in the CFR-PEEK2-group. After 24 months, the mean CMS was 89.9 points (pt) (44.5-100 pt) and the mean SSV was 86.7% (35-100%). Compared to the matched-pair TAL-P cohort, the 24-month follow-up showed similar results (CMS: 88.6 pt. (40.5-100 pt.) [p = 0.9]; SSV: 76% (30-100%) [p = 0.05]). However, significantly better degrees of forward flexion and internal rotation as well as a better range of motion in abduction was recorded in patients treated with CFR-PEEK2 plates than TAL-P. CONCLUSION: At the 24-month follow-up, patients who received treatment with CFR-PEEK2 compared to those that received TAL-P showed enhanced range of motion whilst having similar clinical scores.


Subject(s)
Polymers , Shoulder Fractures , Humans , Middle Aged , Retrospective Studies , Benzophenones , Bone Plates/adverse effects , Fracture Fixation, Internal/methods , Treatment Outcome
7.
J Shoulder Elbow Surg ; 32(6): 1185-1195, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36584871

ABSTRACT

BACKGROUND: Arthroscopy-assisted cortical fixation devices have been increasingly used in the operative management of both acute and chronic cases of acromioclavicular joint instability (ACJI). It has been hypothesized that delayed surgical management leads to inferior clinical and radiologic outcomes compared to acute treatment. The purpose of this study is to compare clinical and radiologic outcomes, scapula dyskinesia, and failure or revision rates of arthroscopically treated acute and chronic ACJI. METHODS: This retrospective study of prospectively collected data included all surgically treated patients with grade IIIb and V chronic ACJI between 2013 and 2017, matched 1:1 to a group of acute grade IIIb and V ACJI patients treated during the same time period. Chronic ACJI was defined as delayed surgical treatment >21 days after injury. Chronic cases received an additional hamstring autograft next to the suture pulley systems. Follow-up was obtained at an average of 3.2 years (range: 1.4-6.2). Clinical outcome scores included the Constant-Murley Score (CMS), Taft Score (TF), Nottingham Clavicle Score (NCS), ACJI Score, Sick Scapula Score (SSS), Subjective Shoulder Value (SSV), Subjective Shoulder Test (SST), American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES) score, and the visual analog scale pain score. Radiologic follow-up was obtained pre- and postoperatively and at final follow-up. The 2-year results were compared to the results of a 1:1 matched-pair group comprising patients who were treated with an acute ACJI during the same period. RESULTS: Thirty-three (80.5%) of 41 chronic ACJI cases were available for follow-up and were compared with 33 matched-pair cases of acute ACJI (of 41). The clinical scores were significantly better in the acute cohort for the CMS (92 ± 8 vs. 88 ± 8, P = .030), ASES (91 ± 13 vs. 85 ± 13, P = .002), SSS (1.4 ± 1.6 vs. 3.4 ± 2.5, P = .0004), NCS (86 ± 13 vs. 81 ± 13, P = .049), TF (9.9 ± 1.9 vs. 9.0 ± 2.1, P = .030), and ACJI (83 ± 13 vs. 75 ± 1, P = .003). In contrast to the chronic cohort, the acute cohort illustrated a significant loss of reduction at follow-up (P = .020). CONCLUSION: Based on the results of this study, early arthroscopy-assisted operative treatment of grade IIIb and V ACJIs seems superior to delayed surgical intervention of grade IIIb and V ACJIs. Furthermore, an additional autograft loop leads to less loss of reduction compared with suture pulley/suspensory loop fixation standalones.


Subject(s)
Acromioclavicular Joint , Joint Dislocations , Joint Instability , Humans , Joint Dislocations/surgery , Acromioclavicular Joint/surgery , Acromioclavicular Joint/injuries , Treatment Outcome , Retrospective Studies , Radiography , Joint Instability/surgery , Joint Instability/diagnostic imaging , Arthroscopy/methods
8.
Orthop Rev (Pavia) ; 14(4): 37042, 2022.
Article in English | MEDLINE | ID: mdl-35910546

ABSTRACT

Background: Anatomic total shoulder arthroplasty (TSA) has been continuously developed and current designs include stemless or canal-sparing humeral components. In the literature stemless and canal sparing TSA showed good clinical and radiographic results, which were comparable to stemmed TSA. Objective: The aim of this study was to determine the short-term clinical and radiological outcomes of a new stemless TSA design. Methods: A prospective multicentre study including 154 total shoulder arthroplasty patients with a follow up of 12 months was performed. At the time of follow up 129 patients were available for review. The adjusted Constant Murley score,1 Oxford Shoulder Score, EQ-5D-5L score and radiographs were examined preoperatively, 3 and 12 months after the implantation of the new stemless TSA implant GLOBAL ICON™ (DePuy Synthes, Warsaw, IN, USA). Complications were documented. Results: Implant Kaplan-Meier survivorship was 98.7% at 12 months. From baseline to 12 months follow-up, all scores showed a progressive significant mean improvement. The mean adjusted Constant score increased from 42.3 to 96.1 points (p<0.001). The Oxford Shoulder Score showed an increase of 21.6 points (p<0.001). The postoperative radiographs showed no continuous radiolucent lines, subsidence, aseptic loosening or progressive radiolucency, but one osteolytic lesion was observed. Only 2 prostheses were revised. Conclusion: The new GLOBAL ICON stemless TSA showed good clinical and radiographic results at short-term follow up which were comparable to early results of other stemless TSA. Further studies with longer follow up are needed in the future.

9.
Orthop J Sports Med ; 10(5): 23259671221094056, 2022 May.
Article in English | MEDLINE | ID: mdl-35592016

ABSTRACT

Background: Various clinical outcome scores have been described to evaluate postoperative shoulder function after operatively treated acromioclavicular joint (ACJ) instability. Clinical outcome scores can be divided between patient-reported outcome measures (PROMs) and examiner-dependent outcome measures (EDOMs) after a clinical examination by a physician. The correlation between PROMs and EDOMs, and thus their interchangeability with regard to operatively treated ACJ instability, has not yet been evaluated. Purpose: To investigate whether PROMs are a reasonable substitute for EDOMs. Correlations between global shoulder (GS) and ACJ-specific outcome measures were also investigated. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: Included in this study were 131 consecutive patients with operatively treated ACJ instability between 2011 and 2017. Postoperative shoulder function was measured using PROMs, including the Subjective Shoulder Value (SSV), Subjective Shoulder Test, and Nottingham Clavicle Score (NCS), and EDOMs, including the Constant-Murley score (CMS), Taft score, ACJ instability (ACJI) score, and SICK Scapula Score (SSS). Associations between PROM and EDOM scores were calculated using the Pearson and Spearman correlation coefficients for linear and nonlinear variables, respectively, and were interpreted using the Cohen classification. The scores were further stratified into GS versus ACJ-specific measures. Results: A strong correlation was observed between several PROMs and EDOMs (CMS vs SSV [r = 0.59; P = .02] and CMS vs NCS [r = 0.79; P ≤ .001]) and between several GS and ACJ-specific scores (CMS vs NCS; CMS vs ACJI [rs = 0.69; P < .001]; and CMS vs SSS [r = -0.68; P < .001]). Conclusion: Based on the results of this study, PROMs such as the SSV (a GS measure) and the NCS (an ACJ-specific measure) can substitute for EDOMs. Clinical Relevance: PROMs that can be substituted for EDOMs can enable the conduct of clinical studies in circumstances in which in-person clinical follow-up of the patient by a physician is not possible.

10.
J Clin Med ; 11(2)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35054102

ABSTRACT

INTRODUCTION: The optimal treatment strategy for the proximal humeral fracture (PHF) remains controversial. The debate is centered around the correct treatment strategy in the elderly patient population. The present study investigated whether age predicts the functional outcome of locking plate osteosynthesis for this fracture entity. METHODS: A consecutive series of patients with surgically treated displaced PHF between 01/2017 and 01/2018 was retrospectively analyzed. Patients were treated by locking plate osteosynthesis. The cohort was divided into two groups: Group 1 (≥65 years) and Group 2 (<65 years). At the follow-up examination, the SSV, CMS, ASES, and Oxford Shoulder Score (OS), as well as a radiological follow-up, was obtained. The quality of fracture reduction is evaluated according to Schnetzke et al. Results: Of the 95 patients, 79 were followed up (83.1%). Group 1 consists of 42 patients (age range: 65-89 years, FU: 25 months) and Group 2 of 37 patients (28-64 years, FU: 24 months). The clinical results showed no significant differences between both groups: SSV 73.4 ± 23.4% (Group 1) vs. 80.5 ± 189% (Group 2). CMS: 79.4 ± 21 vs. 81.9 ± 16, ASES: 77.2 ± 20.4 vs. 77.5 ± 23.1, OS: 39.5 ± 9.1 vs. 40.8 ± 8.2; OS: 39.5 ± 9.1 vs. 40.8 ± 8.2. In the radiological follow-up, fractures healed in all cases. Furthermore, the quality of fracture reduction in both groups is comparable without significant differences. The revision rate was 9.5% in Group 1 vs. 16.2% in Group 2. DISCUSSION: Both age groups show comparable functional outcomes and complication rates. Thus, the locking plate osteosynthesis can be used irrespective of patient age; the treatment decision should instead be based on fracture morphology and individual patient factors.

11.
Arch Orthop Trauma Surg ; 142(12): 3837-3844, 2022 Dec.
Article in English | MEDLINE | ID: mdl-34988672

ABSTRACT

INTRODUCTION: Ligament bracing augments ligament repair using a non-absorbable suture tape. Although biomechanically an increase in primary stability has been proven, there is a lack of clinical evidence. Purpose of this study was to evaluate clinical results of patients treated with ligament bracing due to primary elbow instability, including an analysis of complications. Furthermore, clinical results for patients treated with and without early functional mobilization were compared. MATERIALS AND METHODS: This prospective case-series evaluated clinical and functional results from patients treated with ligament bracing due to primary elbow instability. Clinical outcome measures were range of motion (ROM) as well as objective and subjective elbow scores [Mayo Elbow Performance Score (MEPS); Disabilities of Arm, Shoulder and Hand Score (DASH score)]. Stability was evaluated sonographically by humero-radial gapping under varus stress. RESULTS: This study involved 34 patients treated with ligament bracing. After a mean follow-up of 12.9 months ROM was 112° ± 29, MEPS 88 ± 13 points, DASH 91 ± 11 points, and 84% were satisfied with their result. Lateral joint gapping was 2.4 mm. No significant difference was observed regarding a postoperative mobilization with and without limitations. Most common complication after ligament bracing was elbow stiffness including heterotopic ossifications in four patients (12%). CONCLUSION: Operatively treated elbow instability with additional ligament bracing results in good clinical outcomes with high patient satisfaction and recovery of elbow stability. The high primary stability of the ligament bracing allows early functional mobilization without bracing, which facilitates postoperative rehabilitation. Elbow stiffness with heterotopic ossification seems to be a potential complication. Furthermore, the optimal tensioning of the ligament bracing remains challenging, including the risk of an over tensioning. LEVEL OF EVIDENCE: III.


Subject(s)
Collateral Ligaments , Elbow Joint , Joint Instability , Ossification, Heterotopic , Humans , Elbow Joint/surgery , Elbow , Joint Instability/surgery , Joint Instability/etiology , Collateral Ligaments/surgery , Braces/adverse effects , Range of Motion, Articular , Treatment Outcome
12.
Sportverletz Sportschaden ; 36(1): 49-54, 2022 03.
Article in German | MEDLINE | ID: mdl-35016243

ABSTRACT

Scapular fractures are a rare injury entity accounting for 0,4-1 % of all fractures and 3-5 % of fractures involving the shoulder girdle. This study focuses on a 29-year-old male patient who sustained an intraarticular scapular fracture during a "Rugby Bundesliga" match after direct impact with another player. The clinical and radiological examinations showed a dislocated multifragmentary transverse scapular fracture involving the superior border, the medial border and the glenoid (Euler and Rüedi D2b/AO 14 F1.3e). The patient was subjected to arthroscopic surgery and underwent early postoperative functional rehabilitation without weight-bearing and with a limited range of motion of 90° abduction/anteversion. In the first match of the second half of the season (5 months post-operatively), the patient was available to play, and in the clinical follow-up 6 months post-operatively, he was pain-free with excellent clinical results (CS 100 pt, SSV 98 %, OSS 12 pt, ASES 100 pt). No pain or restrictions in the range of motion were reported. In conclusion, the arthroscopic-assisted management of intra-articular scapular fractures is a safe and effective choice of treatment in young and active patients.


Subject(s)
Fractures, Bone , Shoulder Fractures , Adult , Arthroscopy/methods , Fracture Fixation, Internal/methods , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Humans , Male , Range of Motion, Articular , Retrospective Studies , Rugby , Scapula/diagnostic imaging , Scapula/injuries , Scapula/surgery , Shoulder Fractures/surgery , Treatment Outcome
13.
Z Orthop Unfall ; 160(3): 287-298, 2022 06.
Article in English, German | MEDLINE | ID: mdl-33530111

ABSTRACT

BACKGROUND: The management of proximal humeral fracture (PHF) is not only complex but ever changing. Published epidemiological data are often dated and do not factor in demographic changes or the latest developments in implant material and surgical techniques. AIMS: The primary aim of this study was to evaluate changes in the epidemiology and actual treatment of PHF at a level-1 trauma centre, with a special focus on shoulder surgery. HYPOTHESES: 1. Between 2009 to 2012 and 2014 to 2017, an increase in complex PHF entities can be observed. 2. In correlation with fracture complexity, an increasing number of comorbidities, especially osteoporosis, can be observed. METHODS: Between 2014 and 2017, a total of 589 patients (73% female; mean age: 68.96 ± 14.9 years) with 593 PHFs were treated. Patient records and imaging (XRs and CTs) of all patients were analysed. Fractures with ad latus displacement of a maximum of 0,5 cm and/or humeral head angulation of less than 20° were classified as non-displaced. Patients with displaced fractures were included in the analysis of the therapeutic algorithm. These results were compared to those of a cohort 2009 to 2012 (566 patients, 569 PHFs), which used the same inclusion criteria. RESULTS: The two cohorts showed comparable patient numbers, as well as gender and age distributions. Between 2009 to 2012 and 2014 to 2017, a decrease in 2-part fractures (13.9 to 8.6%) and a simultaneous increase in 4-part fractures (20.4 to 30%), and thus fracture complexity was observed. Further decreases were observed in conservative therapy (27.8 to 20.6%), nail osteosynthesis (10.7 to 2.7%) and anatomic shoulder arthroplasty (5,4 to 1%). Furthermore, there was an increase in the use of locking plate osteosynthesis (43.2 to 56.7%) and reverse shoulder arthroplasty (9 to 18.4%). The general trend shows an increase in surgical therapy between the years (72.2 to 79.4%), as well as an increase in osteoporosis incidence (13 to 20.6%). The greatest numbers of comorbidities were found in 3- and 4-part fractures. CONCLUSION: There is an increase in both the complexity of fractures and the number of surgically treated fractures between 2009 and 2012. Furthermore, an increase in osteoporosis numbers can be observed. New implants (PEEK, fenestrated screws for cement augmentation) and new surgical techniques (double plating osteosynthesis) were used as a result of increasing fracture complexity. Moreover, reverse total shoulder arthroplasty was used more commonly.


Subject(s)
Osteoporosis , Shoulder Fractures , Aged , Aged, 80 and over , Bone Plates/adverse effects , Female , Fracture Fixation, Internal/methods , Humans , Male , Middle Aged , Retrospective Studies , Shoulder , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/epidemiology , Shoulder Fractures/surgery , Trauma Centers , Treatment Outcome
14.
Arch Orthop Trauma Surg ; 142(6): 1083-1090, 2022 Jun.
Article in English | MEDLINE | ID: mdl-33944989

ABSTRACT

INTRODUCTION: There is no uniform approach to the management of lateral clavicle fractures. Recent studies have investigated additive coracoclavicular (CC) augmentation as a treatment option; however, it is unclear whether it is superior to conventional locking plate osteosynthesis. METHODS: We carried out a retrospective analysis of 40 patients with lateral clavicle fracture (Neer type IIb) who were treated between 2014 and 2017 with either a hybrid locking plate osteosynthesis/additive arthroscopy-assisted CC augmentation (HP) procedure or a locking plate osteosynthesis only (PO) approach to determine which strategy was more effective. At follow-up, subjective shoulder value, age- and sex-adjusted Constant-Murley score, Taft (TF) score, American Shoulder and Elbow score, Nottingham clavicle score, and Visual Analogue Scale score were compared between patient groups. A radiologic evaluation was also conducted. RESULTS: A total of 14/17 patients (83%; 9 male/5 female, mean age: 43 ± 15 years) were followed up in the PO group. The mean follow-up time was 29 ± 12.4 months. In the HP group, 17/23 patients (74%; 9 male/8 female, mean age: 43 ± 17 years) were followed up, with a mean follow-up time of 18 ± 7.1 months. There were no significant differences in clinical parameters between the HP and PO groups; notably, the shoulder girdle-specific TF score was comparable in the 2 groups (HP: 11.3 ± 1.1 points and PO: 10.9 ± 0.9 points). In the HP group, additional pathologies were identified and arthroscopically treated in 35% of cases. Radiologic examination revealed a significant difference between pre- and postoperative CC distance in the HP group (P = 0.001). CONCLUSION: Additive CC augmentation in combination with locking plate osteosynthesis seems to improve the vertical stability and reduces the revision rate in patients with a lateral clavicle fracture. Furthermore, an arthroscopy-assisted procedure allows for an intraoperative detection and single-step treatment of accompanying intraarticular pathologies.


Subject(s)
Clavicle , Fractures, Bone , Adult , Bone Plates , Clavicle/surgery , Female , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Humans , Ligaments, Articular/surgery , Male , Middle Aged , Retrospective Studies , Treatment Outcome
15.
Z Orthop Unfall ; 160(5): 549-558, 2022 10.
Article in English, German | MEDLINE | ID: mdl-33873227

ABSTRACT

BACKGROUND: Tension band wiring is the standard procedure for patellar fractures, but is associated with a high rate of implant related complications and implant failure. Tension band wiring may fail, especially with multifragmentary and comminuted fractures. Plate fixation of complex patellar fractures seems to be superior to wiring, both clinically and biomechanically. The aim of this study was to evaluate complications after locking plate fixation in patellar fractures two years after surgery and to access the functional outcome. MATERIAL AND METHODS: As part of a prospective case series, all patients who had received locking plate fixation of a patellar fracture between April 2013 and May 2018 were clinically examined two years postoperatively and potential complications were evaluated. RESULTS: A total of 38 patients aged 19 - 87 years were included. Complications occurred in a total of five patients (13%), including one reactive prepatellar bursitis, one chronic infection and loss of reduction due to a dislocated pole fragment in three cases. The average active range of motion of the affected knee joint two years postoperatively was 133°. The Tegner activity scale score reached 3 points, the Lysholm score 95 points and the Kujala score 95 points. CONCLUSION: With an overall relatively low complication rate and good clinical outcome, dislocated distal pole fragments are a common complication after plate fixation of patellar fractures. If preoperative diagnostic testing shows a pole fragment, a modified hook-plate can be used, with the possibility of fixing the pole fragment.


Subject(s)
Fractures, Bone , Fractures, Comminuted , Joint Dislocations , Knee Injuries , Bone Plates/adverse effects , Bone Wires , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Fractures, Comminuted/surgery , Humans , Patella/surgery , Postoperative Complications/etiology , Postoperative Complications/surgery , Retrospective Studies , Treatment Outcome
16.
J Hand Surg Am ; 47(10): 1016.e1-1016.e8, 2022 10.
Article in English | MEDLINE | ID: mdl-34565637

ABSTRACT

PURPOSE: Ligament bracing is a technique of suture reinforcement that can be used to augment lateral ulnar collateral ligament repair in the treatment of posterolateral rotatory instability of the elbow, thereby improving early stability of the repair. However, multiple failures of the ulnar anchor during implantation have been documented. We hypothesized that the use of a cortical button for ulnar fixation of the ligament brace would be biomechanically comparable to a suture anchor construct. METHODS: Sixteen elbows were tested with a materials testing machine. The intact, dissected, and repaired lateral collateral ligament complex was tested with a cyclic varus rotational torque of 0.5-3.5 Nm in 120°, 90°, 60°, and 30° elbow flexion. For the repair, the specimens were randomized into 2 groups: ulnar fixation of the ligament bracing using a suture anchor and ulnar fixation of the ligament bracing using a cortical button. The number of implant failures was documented. A load-to-failure protocol was conducted in 90° elbow flexion. RESULTS: Load to failure was comparable and was found to be 20.7 Nm in the suture anchor group and 21.8 Nm in the cortical button group. Laxity after ligament bracing did not differ significantly between suture anchor and cortical button fixation. Compared with the native ligament, the laxity was significantly reduced after ligament bracing. The failure mode was slippage of the suture tape through the humeral anchor in all cases. Additionally, the capitellum was damaged in 9 of 16 cases. CONCLUSIONS: A cortical button for ulnar fixation of the ligament bracing was comparable with a suture anchor fixation with regard to biomechanical properties such as laxity and load to failure. CLINICAL RELEVANCE: A cortical button fixation is less prone to failure of insertion. This would improve the implantation technique, while clinical results are expected to be comparable.


Subject(s)
Collateral Ligament, Ulnar , Collateral Ligaments , Elbow Joint , Biomechanical Phenomena , Braces , Cadaver , Collateral Ligament, Ulnar/surgery , Collateral Ligaments/surgery , Elbow Joint/surgery , Humans
17.
Injury ; 52(8): 2285-2291, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34148652

ABSTRACT

INTRODUCTION: A stable fixation of highly unstable proximal humerus fractures remains challenging and complication rates, especially secondary varus dislocation, remains high. Different techniques of double plate osteosynthesis have been suggested for the treatment of complex proximal humeral fractures as they are well established for other fractures. The aim of this study was to evaluate an operative technique using an angular stable lateral plate supported by a one-third tubular plate positioned anteriorly at the lesser tuberosity for unstable proximal humeral fractures. PATIENTS AND METHODS: Retrospectively, patients treated with a double plate osteosynthesis were included between January 2014 and December 2017. Out of 31, 25 patients (80.6%) with an average age of 53.1 years ± 12.5 were available for follow-up. 60% of the patients were male. The clinical evaluation consisted of a physical examination and standardised questionnaire including subjective and objective shoulder scores like the Constant-Murley Shoulder Score, Simple Shoulder Score, and Subjective Shoulder Value. RESULTS: After a mean follow-up of 30.9 months (range, 12-76 months) eighteen patients (72%) had either excellent or good results regarding the Constant-Murley Shoulder Score with a mean value of 77 points ± 17. Average Simple Shoulder Score was 76% ± 0.2 and Subjective Shoulder Value 72% ± 0.2%. Mean NSA at time of follow-up 135° ± 13°. Nine patients had an implant-removal, five in combination with arthrolysis after a mean of 7.2 months. Three patients underwent surgery for secondary arthroplasty. The study shows a complication rate of 16%. No revision-surgery because of secondary varus dislocation was reported. DISCUSSION: Arthroplasty is the less favourable treatment for a younger, active cohort of patients with highly unstable proximal humeral fractures as results are not as good and options for revision are limited. Double plate osteosynthesis can be used in addition to calcar screws, bone graft augmentation, cement augmentation and additional free screws for more multidirectional stability and shows good clinical results despite a higher rate of avascular necrosis and high primary stability with comparable complication-rates to single plate osteosynthesis. It seems to be a valid alternative to primary fracture arthroplasty and can prevent secondary varus displacement.


Subject(s)
Shoulder Fractures , Bone Plates , Fracture Fixation, Internal , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Shoulder Fractures/diagnostic imaging , Shoulder Fractures/surgery , Treatment Outcome
18.
Clin Biomech (Bristol, Avon) ; 81: 105236, 2021 01.
Article in English | MEDLINE | ID: mdl-33234324

ABSTRACT

BACKGROUND: Although an additional internal bracing significantly increases stability in a repair of the lateral ulnar collateral ligament, it remains unclear whether it also does in reconstruction. Aim of this study was to implement a three-dimensional elbow simulator for testing posterolateral rotatory instability. We hypothesized that (1) reconstruction with and without internal bracing is comparable in biomechanical properties, and (2) there would be higher load-to-failure with internal bracing. METHODS: Posterolateral rotatory instability was tested by imitating the lateral pivot shift test in 16 elbows. Valgus and supination torques were simultaneously increased stepwise up to 1.2 Nm. Specimens were tested at 30°, 60°, 90°, and 120° elbow flexion with an intact lateral collateral ligament complex, dissected complex, and after reconstruction with or without internal bracing. Outcome measures included joint gapping, laxity, and load to failure. FINDINGS: With the implemented elbow simulator no significant difference was observed for gapping or laxity between both treatment groups. Comparing treatment and native ligament, gapping was reduced, especially with increased elbow flexion. Laxity was also reduced at some flexion angles. The mean load-to-failure was 8.1 ± 2.7 Nm without and 9.6 ± 3.6 Nm with internal bracing (P = 0.645). INTERPRETATION: Both treatments were comparable in biomechanical properties but did not fully restore the native state. Although the additional augmentation of the LUCL reconstruction tends to increase the maximum load to failure, this difference was not statistically significant. Still, reconstruction with internal bracing seems to be a reasonable option in selected primary reconstructions. It could also be useful in revision reconstruction.


Subject(s)
Collateral Ligament, Ulnar/surgery , Elbow/surgery , Mechanical Phenomena , Biomechanical Phenomena , Braces , Collateral Ligament, Ulnar/physiology , Female , Humans , Male , Range of Motion, Articular , Rotation , Torque
19.
Arch Orthop Trauma Surg ; 141(10): 1649-1657, 2021 Oct.
Article in English | MEDLINE | ID: mdl-32780199

ABSTRACT

INTRODUCTION: The aim of the present study was to analyze the injury pattern and thus the dislocation mechanism after simple elbow dislocation using radiographs and magnetic resonance imaging (MRI) data sets. MATERIALS AND METHODS: The MRI data sets of 64 patients with a mean age of 44 years (18-77 years) were analyzed retrospectively. The inclusion criteria for the study were (1) radiograph with confirmed simple elbow dislocation, (2) low-energy trauma, (3) MRI of the affected elbow ≤ 3 weeks after trauma. The dislocation direction was determined using radiographs. The integrity of the lateral collateral ligament complex (LCLC), common extensor origin (CEO), anterior capsule (AC), medial collateral ligament (MCL), and common flexor origin (CFO) as well as the joint congruity were assessed based on MRI. RESULTS: 34 patients (53%) had a posterolateral, 26 patients (41%) a posterior, and 4 patients (6%) a posteromedial dislocation. LCLC and AC were affected in 64 out of 64 patients (100%). MCL was affected in 58 patients (91%). CEO were affected in 25 patients (39%) and the CFO in 20 patients (31%). In 11 patients (17%) the injury pattern was more pronounced medially than laterally (MCL, CFO, LCLC), with 2 of these patients exhibiting only a partial LCLC tear. All cases with joint incongruency (n = 12, 19%) showed CEO and/or CFO involvement. CONCLUSIONS: Simple elbow dislocation leads to a very heterogeneous spectrum of soft tissue injury pattern. A small proportion of patients showed medially pronounced injury patterns. These findings strongly indicate existence of a "reversed Horii circle" with an underlying valgus mechanism (medial force induction) originating and continuing from medial to anterior.


Subject(s)
Collateral Ligaments , Elbow Joint , Joint Instability , Adult , Elbow , Elbow Joint/diagnostic imaging , Humans , Retrospective Studies
20.
Knee Surg Sports Traumatol Arthrosc ; 29(1): 284-291, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32162045

ABSTRACT

PURPOSE: Simple elbow dislocations are accompanied with lateral ulnar collateral ligament ruptures. For persisting instability, surgery is indicated to prevent chronic posterolateral rotatory instability. After lateral collateral ligament (LCL) complex repair the repair is protected by temporary immobilization, limited range of motion and hinged bracing. Internal bracing is an operative alternative augmenting the LCL repair using non-absorbable suture tapes. However, the stability of LCL repair with and without additional augmentation remains unclear. The hypothesis was that LCL repair with additional suture tape augmentation would improve load to failure. Secondary goal of this study was to evaluate different humeral fixation techniques. A humeral fixation using separate anchors for the LCL repair and the augmentation was not expected to provide superior stability compared to using only one single anchor. METHODS: Twenty-one elbows were tested. A cyclic varus rotational torque of 0.5-3.5 Nm was applied in 90°, 60°, 30°, and 120° elbow flexion to the intact, torn, and repaired LCLs. The specimens were randomized into three groups: repair alone (group I), repair with additional internal bracing using two anchors (group II), repair using one humeral anchor (group III). A load-to-failure protocol was conducted. RESULTS: Load to failure was significantly higher in groups II (26.6 Nm; P = 0.017) and III (23.18 Nm; P = 0.038) than in group I (12.13 Nm). No significant difference was observed between group II and III. All specimens lost reduction after LCL dissection by a mean of 4.48° ± 4.99° (range 0.66-15.82). The mean reduction gain after repair was 7.21° ± 4.97° (2.70-21.23; mean over reduction, 2.73°). The laxity was comparable between the intact and repaired LCLs (n.s.), except for varus movements at 30° in group II (P = 0.035) and 30° (P = 0.001) and 120° in group III (P = 0.008) with significantly less laxity. Inserting the ulnar suture anchor showed failure in the thread in 10 cases. CONCLUSION: LCL repair with additional internal bracing yielded higher load to failure than repair alone. Repair with additional internal bracing for the humeral side using one anchor was sufficient. A higher primary stability would facilitate postoperative management and allow immediate functional treatment. Reducing the number of humeral anchors would save costs.


Subject(s)
Collateral Ligament, Ulnar/surgery , Elbow Joint/surgery , Joint Instability/surgery , Sutures , Aged , Biomechanical Phenomena , Cadaver , Collateral Ligament, Ulnar/injuries , Collateral Ligament, Ulnar/physiopathology , Elbow Joint/physiopathology , Female , Humans , Humerus/surgery , Joint Instability/physiopathology , Male , Middle Aged , Range of Motion, Articular , Rotation , Rupture/surgery , Suture Anchors , Tensile Strength , Torque , Elbow Injuries
SELECTION OF CITATIONS
SEARCH DETAIL
...