1.
MAGMA ; 27(1): 63-70, 2014 Feb.
Article in English | MEDLINE | ID: mdl-23748497

ABSTRACT

OBJECT: MR imaging of low-gamma nuclei at the ultrahigh magnetic field of 21.1 T provides a new opportunity for understanding a variety of biological processes. Among these, chlorine and sodium are attracting attention for their involvement in brain function and cancer development. MATERIALS AND METHODS: MRI of (35)Cl and (23)Na were performed and relaxation times were measured in vivo in normal rat (n = 3) and in rat with glioma (n = 3) at 21.1 T. The concentrations of both nuclei were evaluated using the center-out back-projection method. RESULTS: T 1 relaxation curve of chlorine in normal rat head was fitted by bi-exponential function (T 1a = 4.8 ms (0.7) T 1b = 24.4 ± 7 ms (0.3) and compared with sodium (T 1 = 41.4 ms). Free induction decays (FID) of chlorine and sodium in vivo were bi-exponential with similar rapidly decaying components of [Formula: see text] ms and [Formula: see text] ms, respectively. Effects of small acquisition matrix and bi-exponential FIDs were assessed for quantification of chlorine (33.2 mM) and sodium (44.4 mM) in rat brain. CONCLUSION: The study modeled a dramatic effect of the bi-exponential decay on MRI results. The revealed increased chlorine concentration in glioma (~1.5 times) relative to a normal brain correlates with the hypothesis asserting the importance of chlorine for tumor progression.


Subject(s)
Brain Neoplasms/pathology , Chlorine/chemistry , Glioma/pathology , Magnetic Resonance Imaging/methods , Sodium/chemistry , Animals , Disease Progression , Equipment Design , Imaging, Three-Dimensional , Rats
2.
J Magn Reson ; 221: 110-6, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22750638

ABSTRACT

A tunable 900 MHz transmit/receive volume coil was constructed for ¹H MR imaging of biological samples in a 21.1 T vertical bore magnet. To accommodate a diverse range of specimen and RF loads at such a high frequency, a sliding-ring adaptation of a low-pass birdcage was implemented through simultaneous alteration of distributed capacitance. To make efficient use of the constrained space inside the vertical bore, a modular probe design was implemented with a bottom-adjustable tuning and matching apparatus. The sliding ring coil displays good homogeneity and sufficient tuning range for different samples of various dimensions representing large span of RF loads. High resolution in vivo and ex vivo images of large rats (up to 350 g), mice and human postmortem tissues were obtained to demonstrate coil functionality and to provide examples of potential applications at 21.1 T.


Subject(s)
Neuroimaging/instrumentation , Algorithms , Alzheimer Disease/pathology , Animals , Brain/pathology , Cadaver , Electromagnetic Fields , Equipment Design , Humans , Mice , Phantoms, Imaging , Rats , Rats, Sprague-Dawley