Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Intern Emerg Med ; 19(4): 971-981, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38446371

ABSTRACT

Acute kidney injury (AKI) is a critical complication of sepsis. There is a continuous need to identify and validate biomarkers for early detection. Serum and urinary biomarkers have been investigated, such as neutrophil gelatinase associated lipocalin (NGAL) and cystatin C (Cys C), but their reliability in the intensive care unit (ICU) remains unknown. Renal hemodynamics can be investigated by measuring the renal resistive index (RRI). This study aimed to compare the performance of RRI, serum NGAL (sNGAL), urinary NGAL (uNGAL), and serum Cys C levels as early predictors of the diagnosis and persistence of sepsis-associated AKI. A total of 166 adult patients with sepsis syndrome were enrolled immediately after ICU admission. Biomarkers were measured directly (T1) and on day 3 (T3). RRI was measured directly (T1) and 24 h later (T2). Patients were categorized (according to the occurrence and persistence of AKI within the first 7 days) into three groups: no AKI, transient AKI, and persistent AKI. The incidence rate of sepsis-associated AKI was 60.2%. Sixty-six patients were categorized as in the no AKI group, while another 61 were in transient AKI and only 39 were in persistent AKI. The RRI value (T1 ≥ 0.72) was the best tool for predicting AKI diagnosis (area under the receiver operating characteristic curve, AUROC = 0.905). Cys C (T1 ≥ 15.1 mg/l) was the best tool to predict the persistence of AKI (AUROC = 0.977). RRI (T1) was the best predictive tool for sepsis-associated AKI, while Cys C was the best predictor of its persistence and 28-day mortality.


Subject(s)
Acute Kidney Injury , Biomarkers , Cystatin C , Lipocalin-2 , Sepsis , Humans , Acute Kidney Injury/etiology , Acute Kidney Injury/physiopathology , Biomarkers/blood , Biomarkers/analysis , Male , Female , Sepsis/complications , Sepsis/physiopathology , Middle Aged , Aged , Cystatin C/blood , Lipocalin-2/blood , Lipocalin-2/urine , Lipocalin-2/analysis , Predictive Value of Tests , Renal Artery/physiopathology , Renal Artery/diagnostic imaging , Prospective Studies , Intensive Care Units/statistics & numerical data , Intensive Care Units/organization & administration , ROC Curve , Early Diagnosis
2.
Eur J Radiol ; 154: 110412, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35724580

ABSTRACT

PURPOSE: To evaluate the diagnostic accuracy of the dual gradient-echo (GRE) in- and out-of-phase sequences as a quantitative tool for hepatic iron overload in comparison with MRI R2* relaxometry in paediatric patients with beta-thalassemia. METHOD: Sixty-three patients with beta-thalassemia major (transfusion-dependent) or beta-thalassemia intermedia (transfusion- and non-transfusion-dependent) were referred from the paediatric department (haematology unit) to the radiology department at a university hospital. The paediatrician conducted a clinical examination for the studied group, assessed their laboratory data, conducted R2* relaxometry and dual gradient echo sequences to calculate R2* and relative signal intensity index at the axial mid-section of the liver, and studied their correlation. A 1.5 Tesla MR scanner was used (Achieva; Philips Medical Systems, the Netherlands). Data were fed to the computer and analysed using the IBM SPSS software package version 20.0 (Armonk, NY: IBM Corp). The Kolmogorov-Smirnov test was used to verify the normality of distribution. The significance of the results was determined at the 5% level. The Chi-square, Fisher's exact correction, Pearson coefficient, and Bland-Altman tests were used. RESULTS: Dual gradient-echo in- and out-of-phase sequences using visual assessment accurately assessed 93.65% of our patient group with hepatic iron overload. A significant correlation was found between the relative signal intensity index and hepatic MRI R2* relaxometry (p < 0.001, r = 0.861). CONCLUSIONS: Dual gradient-echo in and out-of-phase sequences are good imaging tools for hepatic iron detection and quantification. These sequences showed good correlation with R2* relaxometry (r = 0.861, p < 0.001).


Subject(s)
Iron Overload , beta-Thalassemia , Child , Humans , Iron/analysis , Iron Overload/diagnostic imaging , Liver/diagnostic imaging , Magnetic Resonance Imaging/methods , beta-Thalassemia/complications , beta-Thalassemia/diagnostic imaging
3.
Br J Radiol ; 93(1110): 20200035, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32142374

ABSTRACT

OBJECTIVE: Ultrasound elastography is increasingly used in the diagnosis of prostate cancer, however results are heterogeneous. We correlate in a large sample-size prospective study the accuracy of elastography, aiming to settle an accurate cut-off point for diagnosis and possibility of use as a screening tool. METHODS: Prospective study that included 120 patients with mean age 59.5 ± 9.8 years, showing enlarged prostate by clinical examination with prostate-specific antigen >4 ng ml-1.The study was done using high frequency high resolution endorectal probe with real time tissue elastography.Grayscale ultrasound examination was done first with Doppler followed by elastography color-coded map and strain ratio measurement. Then, transrectal ultrasound-guided core biopsy was done from suspicious areas detected by elastography (totally or partly stiff by color-coded map or with relative increased strain ratio), besides standard six-quadrant core biopsy samples. RESULTS: There was statistically significant difference (p < 0.001) regarding strain ratio in benign and malignant lesions. Strain ratio showed significant proportionate correlation with prostate-specific antigen level and Gleason pathological score, while no significant correlation noted with the age or the prostatic volume. A strain ratio with a cut-off value of 1.9 showed a sensitivity of 100%, specificity 93.8%, positive predictive value of 79.3%, negative predictive value 100 and 95% accuracy in differentiating between malignant and benign lesions. CONCLUSION: Strain ratio improves the detection of prostatic cancer with high sensitivity (100%) and high negative predictive value (100%). ADVANCES IN KNOWLEDGE: Different prostatic lesions are mostly similar in grayscale ultrasound.Imaging plays an important role in differentiation of prostatic nodules.Ultrasound elastography may play an important role in distinguishing benign from malignant nodules.


Subject(s)
Elasticity Imaging Techniques/methods , Prostate/diagnostic imaging , Prostatic Neoplasms/diagnostic imaging , Aged , Echocardiography, Doppler, Color , Humans , Image-Guided Biopsy/methods , Male , Middle Aged , Neoplasm Grading , Predictive Value of Tests , Prospective Studies , Prostate/pathology , Prostate-Specific Antigen/blood , Prostatic Neoplasms/pathology , Sample Size , Sensitivity and Specificity
4.
Paediatr Anaesth ; 25(4): 421-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25581094

ABSTRACT

INTRODUCTION: Propofol and midazolam are widely used for pediatric magnetic resonance imaging (MRI) sedation. Increasing depth of sedation may be associated with airway obstruction. A neck collar supporting the mandible and maintaining the head in slight extension may be beneficial in maintaining airway patency. AIM OF THE STUDY: Primary aim: To assess upper airway size with and without a neck collar during pediatric MRI sedation with propofol-midazolam. Secondary aim: To evaluate complications encountered during the procedure. MATERIALS AND METHODS: Sixty patients aged 2-4 years scheduled for MRI of the brain were selected. They were sedated with intramuscular midazolam 0.1 mg·kg(-1) 30 min before the procedure. Patients were sedated with i.v. propofol 1 mg·kg(-1) and continued with 50-100 µg·kg(-1) ·min(-1) . T1 3D fast-field echo axial sequence from the nasopharyngeal roof to subglottic region was taken with and without application of a neck collar. Airway dimensions were measured and analyzed at the base of the tongue, soft palate, and at the epiglottis. RESULTS: At the base of the tongue and soft palate, the cross-sectional area (CSA) and the anteroposterior diameter of the airway were respectively statistically significantly higher when the neck collar was applied. The CSA at the epiglottis was significantly less with application of the neck collar. Complications were not significantly different between the two sequences. CONCLUSION: Application of a soft neck collar in children aged 2-4 years may enhance the retropalatal and retroglossal airway dimensions during pediatric sedation in the supine position.


Subject(s)
Airway Management/adverse effects , Airway Management/methods , Conscious Sedation/adverse effects , Conscious Sedation/methods , Hypnotics and Sedatives/adverse effects , Magnetic Resonance Imaging/methods , Midazolam/adverse effects , Neck , Propofol/adverse effects , Airway Obstruction/chemically induced , Airway Obstruction/prevention & control , Anatomy, Cross-Sectional , Body Weight , Child, Preschool , Epiglottis/anatomy & histology , Female , Humans , Male , Palate, Soft/anatomy & histology , Tongue/anatomy & histology
SELECTION OF CITATIONS
SEARCH DETAIL
...