Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1356: 277-82, 2014 Aug 22.
Article in English | MEDLINE | ID: mdl-25001334

ABSTRACT

In this short communication we report on the technical implementations of coupling an asymmetric flow field-flow fractionation (AF4) instrument to a high resolution mass spectrometer (Orbitrap) using an atmospheric photoionisation interface. This will allow for the first time online identification of different fullerenes in aqueous samples after their aggregates have been fractionated in the FFF channel. Quality parameters such as limits of detection (LODs), limits of quantification (LOQs) or linear range were evaluated and they were in the range of hundreds ng/L for LODs and LOQs and the detector response was linear in the range tested (up to ∼20 µg/L). The low detection and quantification limits make this technique useful for future environmental or ecotoxicology studies in which low concentration levels are expected for fullerenes and common on-line detectors such as UV or MALS do not have enough sensitivity and selectivity.


Subject(s)
Fullerenes/analysis , Environmental Monitoring , Fractionation, Field Flow/methods , Limit of Detection , Mass Spectrometry/instrumentation , Mass Spectrometry/methods , Solutions
2.
J Chromatogr A ; 970(1-2): 167-81, 2002 Sep 13.
Article in English | MEDLINE | ID: mdl-12350091

ABSTRACT

Identification of unknown water pollutants with liquid chromatography and tandem mass spectrometry (LC-MS-MS) is often more complex and time consuming than identification with gas chromatography and mass spectrometry (GC-MS). In order to focus the identification effort on relevant compounds, unknown peaks need to be selected carefully. Based on its frequency of occurrence in the LC-Diode Array Detection (LC-DAD) chromatograms of surface and infiltrated waters, an unknown peak was selected for identification with LC-MS-MS. This compound was identified as hexamethoxymethylmelamine (HMMM), a chemical often used in the coating industry. This is the first time the presence of this chemical in surface waters has been reported. In addition to HMMM, two other structurally related compounds were found to be present in the investigated surface water. A standard mixture of HMMM and its by-products did not exhibit (geno)toxicity under the test conditions applied in this study. In another example, a genotoxic fraction of an industrial wastewater was isolated and examined by LC-MS-MS using a modern quadrupole-orthogonal acceleration-time-of-flight mass spectrometer (Q-TOF). Four compounds were detected. The structures of two compounds present are proposed to be 9-amino-2-hydroxy-acridine and 9-hydroxy-acridine-N-oxide or its structural isomer dihydroxy-acridine. Confirmation with standards could not be carried out, as pure compounds are not available. The other two compounds (structural isomers) could not be identified based on the data available within this study.


Subject(s)
Chromatography, High Pressure Liquid/methods , Mass Spectrometry/methods , Mutagenicity Tests , Water Pollutants, Chemical/analysis , Molecular Weight , Spectrophotometry, Ultraviolet
SELECTION OF CITATIONS
SEARCH DETAIL
...