Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Preprint in English | medRxiv | ID: ppmedrxiv-21252427

ABSTRACT

BackgroundRapid antigen lateral flow devices (LFDs) are set to become a cornerstone of SARS-CoV-2 mass community testing. However, their reduced sensitivity compared to PCR has raised questions of how well they identify infectious cases. Understanding their capabilities and limitations is therefore essential for successful implementation. To address this, we evaluated six commercial LFDs on the same collection of clinical samples and assessed their correlation with infectious virus culture and cycle threshold (Ct) values. MethodsA head-to-head comparison of specificities and sensitivities was performed on six commercial rapid antigen tests using combined nasal/oropharyngeal swabs, and their limits of detection determined using viral plaque forming units (PFU). Three of the LFDs were selected for a further study, correlating antigen test result with RT-PCR Ct values and positive viral culture in Vero-E6 cells. This included sequential swabs and matched serum samples obtained from four infected individuals with varying disease severities. Detection of antibodies was performed using an IgG/IgM Rapid Test Cassette, and neutralising antibodies by infectious virus assay. Finally, the sensitivities of selected rapid antigen LFTs were assessed in swabs with confirmed B.1.1.7 variant, currently the dominant genotype in the UK. FindingsMost of the rapid antigen LFDs showed a high specificity (>98%), and accurately detected 50 PFU/test (equivalent N1 Ct of 23.7 or RNA copy number of 3x106/ml). Sensitivities of the LFDs performed on clinical samples ranged from 65 to 89%. These sensitivities increased in most tests to over 90% for samples with Cts lower than 25. Positive virus culture was achieved for 57 out of 141 samples, with 80% of the positive cultures from swabs with Cts lower than 23. Importantly, sensitivity of the LFDs increased to over 95% when compared with the detection of infectious virus alone, irrespective of Ct. Longitudinal studies of PCR-positive samples showed that most of the tests identified all infectious samples as positive, but differences in test sensitivities can lead to missed cases in the absence of repeated testing. Finally, test performance was not impacted when re-assessed against swabs positive for the dominant UK variant B.1.1.7. InterpretationIn this comprehensive comparison of antigen LFD and virus infectivity, we demonstrate a clear relationship between Ct values, quantitative culture of infectious virus and antigen LFD positivity in clinical samples. Our data support regular testing of target groups using LFDs to supplement the current PCR testing capacity, to rapidly identify infected individuals in situations where they would otherwise go undetected. FundingKings Together Rapid COVID-19, Medical Research Council, Wellcome Trust, Huo Family Foundation.

2.
Preprint in English | medRxiv | ID: ppmedrxiv-20232827

ABSTRACT

Many healthcare facilities report SARS-CoV-2 outbreaks but transmission analysis is complicated by the high prevalence of infection and limited viral genetic diversity. The contribution of different vectors to nosocomial infection or the effectiveness of interventions is therefore currently unclear. Detailed epidemiological and viral nanopore sequence data were analysed from 574 consecutive patients with a PCR positive SARS-CoV-2 test between March 13th and March 31st, when the pandemic first impacted on a large, multisite healthcare institution in London. During this time the first major preventative interventions were introduced, including progressive community social distancing (CSD) policies leading to mandatory national lockdown, exclusion of hospital visitors, and introduction of universal surgical facemask-use by healthcare-workers (HCW). Incidence of nosocomial cases, community SARS-CoV-2 cases and infection in a cohort of 228 HCWs followed the same dynamic course, decreasing shortly after introduction of CSD measures and prior to the main hospital-based interventions. We investigated clusters involving nosocomial cases based on overlapping ward-stays during the 14-day incubation period and SARS-CoV-2 genome sequence similarity. Our method placed 63 (79%) of 80 sequenced probable and definite nosocomial cases into 14 clusters containing a median of 4 patients (min 2, max 19) No genetic support was found for the majority of epidemiological clusters (31/44, 70%) and genomics revealed multiple contemporaneous outbreaks within single epidemiological clusters. We included a measure of hospital enrichment compared to community cases to increase confidence in our clusters, which were 1-14 fold enriched. Applying genomics, we could provide a robust estimate of the incubation period for nosocomial transmission, with a median lower bound and upper bound of 6 and 9 days respectively. Six (43%) clusters spanned multiple wards, with evidence of cryptic transmission, and community-onset cases could not be identified in more than half the clusters, particularly on the elective hospital site, implicating HCW as vectors of transmission. Taken together these findings suggest that CSD had the dominant impact on reducing nosocomial transmission by reducing HCW infection.

3.
Preprint in English | medRxiv | ID: ppmedrxiv-20074351

ABSTRACT

There is a worldwide need for reagents to perform SARS-CoV-2 detection. Some laboratories have implemented kit-free protocols, but many others do not have the capacity to develop these and/or perform manual processing. We provide multiple workflows for SARS-CoV-2 nucleic acid detection in clinical samples by comparing several commercially available RNA extraction methods: QIAamp Viral RNA Mini Kit (QIAgen), RNAdvance Blood/Viral (Beckman) and Mag-Bind Viral DNA/RNA 96 Kit (Omega Bio-tek). We also compared One-step RT-qPCR reagents: TaqMan Fast Virus 1-Step Master Mix (FastVirus, ThermoFisher Scientific), qPCRBIO Probe 1-Step Go Lo-ROX (PCR Biosystems) and Luna(R) Universal Probe One-Step RT-qPCR Kit (Luna, NEB). We used primer-probes that detect viral N (EUA CDC) and RdRP (PHE guidelines). All RNA extraction methods provided similar results. FastVirus and Luna proved most sensitive. N detection was more reliable than that of RdRP, particularly in samples with low viral titres. Importantly, we demonstrate that treatment of nasopharyngeal swabs with 70 degrees for 10 or 30 min, or 90 degrees for 10 or 30 min (both original variant and B 1.1.7) inactivates SARS-CoV-2 employing plaque assays, and that it has minimal impact on the sensitivity of the qPCR in clinical samples. These findings make SARS-CoV-2 testing portable to settings that do not have CL-3 facilities. In summary, we provide several testing pipelines that can be easily implemented in other laboratories and have made all our protocols and SOPs freely available at https://osf.io/uebvj/.

SELECTION OF CITATIONS
SEARCH DETAIL